Cargando…

Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia

BACKGROUND: Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dos...

Descripción completa

Detalles Bibliográficos
Autores principales: Mattar, Essam H., Hammad, Lina F., Al-Mohammed, Huda I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3539560/
https://www.ncbi.nlm.nih.gov/pubmed/21709641
http://dx.doi.org/10.12659/MSM.881833
_version_ 1782255113022210048
author Mattar, Essam H.
Hammad, Lina F.
Al-Mohammed, Huda I.
author_facet Mattar, Essam H.
Hammad, Lina F.
Al-Mohammed, Huda I.
author_sort Mattar, Essam H.
collection PubMed
description BACKGROUND: Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. MATERIAL/METHODS: The measurements involved 32 patient’s (16 males, 16 females), aged between 14–30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. RESULTS: The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. CONCLUSIONS: The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.
format Online
Article
Text
id pubmed-3539560
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-35395602013-04-24 Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia Mattar, Essam H. Hammad, Lina F. Al-Mohammed, Huda I. Med Sci Monit Diagnostics and Medical Technology BACKGROUND: Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. MATERIAL/METHODS: The measurements involved 32 patient’s (16 males, 16 females), aged between 14–30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. RESULTS: The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. CONCLUSIONS: The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment. International Scientific Literature, Inc. 2011-07-01 /pmc/articles/PMC3539560/ /pubmed/21709641 http://dx.doi.org/10.12659/MSM.881833 Text en © Med Sci Monit, 2011 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License.
spellingShingle Diagnostics and Medical Technology
Mattar, Essam H.
Hammad, Lina F.
Al-Mohammed, Huda I.
Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title_full Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title_fullStr Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title_full_unstemmed Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title_short Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
title_sort measurement and comparison of skin dose using onedose mosfet and mobile mosfet for patients with acute lymphoblastic leukemia
topic Diagnostics and Medical Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3539560/
https://www.ncbi.nlm.nih.gov/pubmed/21709641
http://dx.doi.org/10.12659/MSM.881833
work_keys_str_mv AT mattaressamh measurementandcomparisonofskindoseusingonedosemosfetandmobilemosfetforpatientswithacutelymphoblasticleukemia
AT hammadlinaf measurementandcomparisonofskindoseusingonedosemosfetandmobilemosfetforpatientswithacutelymphoblasticleukemia
AT almohammedhudai measurementandcomparisonofskindoseusingonedosemosfetandmobilemosfetforpatientswithacutelymphoblasticleukemia