Cargando…
Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis
BACKGROUND: To quantitatively evaluate the safety and related-toxicities of intensity modulated radiotherapy (IMRT) dose–volume histograms (DVHs), as compared to the conventional three-dimensional conformal radiotherapy (3D-CRT), in gynecologic malignancy patients by systematic review of the related...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3539899/ https://www.ncbi.nlm.nih.gov/pubmed/23176540 http://dx.doi.org/10.1186/1748-717X-7-197 |
_version_ | 1782255160440913920 |
---|---|
author | Yang, Baojuan Zhu, Lin Cheng, Haiyan Li, Qi Zhang, Yunyan Zhao, Yashuang |
author_facet | Yang, Baojuan Zhu, Lin Cheng, Haiyan Li, Qi Zhang, Yunyan Zhao, Yashuang |
author_sort | Yang, Baojuan |
collection | PubMed |
description | BACKGROUND: To quantitatively evaluate the safety and related-toxicities of intensity modulated radiotherapy (IMRT) dose–volume histograms (DVHs), as compared to the conventional three-dimensional conformal radiotherapy (3D-CRT), in gynecologic malignancy patients by systematic review of the related publications and meta-analysis. METHODS: Relevant articles were retrieved from the PubMed, Embase, and Cochrane Library databases up to August 2011. Two independent reviewers assessed the included studies and extracted data. Pooled average percent irradiated volumes of adjacent non-cancerous tissues were calculated and compared between IMRT and 3D-CRT for a range of common radiation doses (5-45Gy). RESULTS: In total, 13 articles comprised of 222 IMRT-treated and 233 3D-CRT-treated patients were included. For rectum receiving doses ≥30 Gy, the IMRT pooled average irradiated volumes were less than those from 3D-CRT by 26.40% (30 Gy, p = 0.004), 27.00% (35 Gy, p = 0.040), 37.30% (40 Gy, p = 0.006), and 39.50% (45 Gy, p = 0.002). Reduction in irradiated small bowel was also observed for IMRT-delivered 40 Gy and 45 Gy (by 17.80% (p = 0.043) and 17.30% (p = 0.012), respectively), as compared with 3D-CRT. However, there were no significant differences in the IMRT and 3D-CRT pooled average percent volumes of irradiated small bowel or rectum from lower doses, or in the bladder or bone marrow from any of the doses. IMRT-treated patients did not experience more severe acute or chronic toxicities than 3D-CRT-treated patients. CONCLUSIONS: IMRT-delivered high radiation dose produced significantly less average percent volumes of irradiated rectum and small bowel than 3D-CRT, but did not differentially affect the average percent volumes in the bladder and bone marrow. |
format | Online Article Text |
id | pubmed-3539899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35398992013-01-10 Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis Yang, Baojuan Zhu, Lin Cheng, Haiyan Li, Qi Zhang, Yunyan Zhao, Yashuang Radiat Oncol Research BACKGROUND: To quantitatively evaluate the safety and related-toxicities of intensity modulated radiotherapy (IMRT) dose–volume histograms (DVHs), as compared to the conventional three-dimensional conformal radiotherapy (3D-CRT), in gynecologic malignancy patients by systematic review of the related publications and meta-analysis. METHODS: Relevant articles were retrieved from the PubMed, Embase, and Cochrane Library databases up to August 2011. Two independent reviewers assessed the included studies and extracted data. Pooled average percent irradiated volumes of adjacent non-cancerous tissues were calculated and compared between IMRT and 3D-CRT for a range of common radiation doses (5-45Gy). RESULTS: In total, 13 articles comprised of 222 IMRT-treated and 233 3D-CRT-treated patients were included. For rectum receiving doses ≥30 Gy, the IMRT pooled average irradiated volumes were less than those from 3D-CRT by 26.40% (30 Gy, p = 0.004), 27.00% (35 Gy, p = 0.040), 37.30% (40 Gy, p = 0.006), and 39.50% (45 Gy, p = 0.002). Reduction in irradiated small bowel was also observed for IMRT-delivered 40 Gy and 45 Gy (by 17.80% (p = 0.043) and 17.30% (p = 0.012), respectively), as compared with 3D-CRT. However, there were no significant differences in the IMRT and 3D-CRT pooled average percent volumes of irradiated small bowel or rectum from lower doses, or in the bladder or bone marrow from any of the doses. IMRT-treated patients did not experience more severe acute or chronic toxicities than 3D-CRT-treated patients. CONCLUSIONS: IMRT-delivered high radiation dose produced significantly less average percent volumes of irradiated rectum and small bowel than 3D-CRT, but did not differentially affect the average percent volumes in the bladder and bone marrow. BioMed Central 2012-11-23 /pmc/articles/PMC3539899/ /pubmed/23176540 http://dx.doi.org/10.1186/1748-717X-7-197 Text en Copyright ©2012 Yang et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Yang, Baojuan Zhu, Lin Cheng, Haiyan Li, Qi Zhang, Yunyan Zhao, Yashuang Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title | Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title_full | Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title_fullStr | Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title_full_unstemmed | Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title_short | Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
title_sort | dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3539899/ https://www.ncbi.nlm.nih.gov/pubmed/23176540 http://dx.doi.org/10.1186/1748-717X-7-197 |
work_keys_str_mv | AT yangbaojuan dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis AT zhulin dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis AT chenghaiyan dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis AT liqi dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis AT zhangyunyan dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis AT zhaoyashuang dosimetriccomparisonofintensitymodulatedradiotherapyandthreedimensionalconformalradiotherapyinpatientswithgynecologicmalignanciesasystematicreviewandmetaanalysis |