Cargando…

Changes in electrophysiological parameters after open carpal tunnel release

BACKGROUND: Carpal tunnel syndrome (CTS) is the most frequent compressive mononeuropathy, affecting mostly females. Few studies have been performed to assess the electrophysiological parameters before and after carpal tunnel release. The purpose of our study was to evaluate these changes postoperati...

Descripción completa

Detalles Bibliográficos
Autores principales: Tahririan, Mohammad A., Moghtaderi, Alireza, Aran, Farzaneh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3544123/
https://www.ncbi.nlm.nih.gov/pubmed/23326777
http://dx.doi.org/10.4103/2277-9175.100151
_version_ 1782255748513792000
author Tahririan, Mohammad A.
Moghtaderi, Alireza
Aran, Farzaneh
author_facet Tahririan, Mohammad A.
Moghtaderi, Alireza
Aran, Farzaneh
author_sort Tahririan, Mohammad A.
collection PubMed
description BACKGROUND: Carpal tunnel syndrome (CTS) is the most frequent compressive mononeuropathy, affecting mostly females. Few studies have been performed to assess the electrophysiological parameters before and after carpal tunnel release. The purpose of our study was to evaluate these changes postoperatively and in the course of a 9-month period after operation in comparison with the preoperative values. MATERIALS AND METHODS: A case-series study was carried out and included 17 cases of moderate or severe electrophysiologically confirmed CTS, who underwent open carpal tunnel release (CTR) from December 2010 to May 2011. Severity grade was assigned following American Association of the Electrodiagnostic Medicine criteria of CTS. Distal motor and sensory latencies and sensory nerve conduction velocity of the median nerve across the carpal tunnel were evaluated and compared before, at 6, and 9 months after surgery. RESULTS: From the 17 evaluated hand with moderate, moderate to severe and severe CTS, severity improvement was reported in 82.3% 6 months and in 88.2% 9 months after surgery, but only 47% had satisfied or completely satisfied opinion about the results. Others, though still complaining of serious symptoms, had improved or normal NCS. DISCUSSION: Electrophysiological investigations outlined severity improvement after CTR. In the current study, the electrophysiological studies were not meaningful in determining outcome.
format Online
Article
Text
id pubmed-3544123
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-35441232013-01-16 Changes in electrophysiological parameters after open carpal tunnel release Tahririan, Mohammad A. Moghtaderi, Alireza Aran, Farzaneh Adv Biomed Res Original Article BACKGROUND: Carpal tunnel syndrome (CTS) is the most frequent compressive mononeuropathy, affecting mostly females. Few studies have been performed to assess the electrophysiological parameters before and after carpal tunnel release. The purpose of our study was to evaluate these changes postoperatively and in the course of a 9-month period after operation in comparison with the preoperative values. MATERIALS AND METHODS: A case-series study was carried out and included 17 cases of moderate or severe electrophysiologically confirmed CTS, who underwent open carpal tunnel release (CTR) from December 2010 to May 2011. Severity grade was assigned following American Association of the Electrodiagnostic Medicine criteria of CTS. Distal motor and sensory latencies and sensory nerve conduction velocity of the median nerve across the carpal tunnel were evaluated and compared before, at 6, and 9 months after surgery. RESULTS: From the 17 evaluated hand with moderate, moderate to severe and severe CTS, severity improvement was reported in 82.3% 6 months and in 88.2% 9 months after surgery, but only 47% had satisfied or completely satisfied opinion about the results. Others, though still complaining of serious symptoms, had improved or normal NCS. DISCUSSION: Electrophysiological investigations outlined severity improvement after CTR. In the current study, the electrophysiological studies were not meaningful in determining outcome. Medknow Publications & Media Pvt Ltd 2012-08-28 /pmc/articles/PMC3544123/ /pubmed/23326777 http://dx.doi.org/10.4103/2277-9175.100151 Text en Copyright: © 2012 Tahririan http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Tahririan, Mohammad A.
Moghtaderi, Alireza
Aran, Farzaneh
Changes in electrophysiological parameters after open carpal tunnel release
title Changes in electrophysiological parameters after open carpal tunnel release
title_full Changes in electrophysiological parameters after open carpal tunnel release
title_fullStr Changes in electrophysiological parameters after open carpal tunnel release
title_full_unstemmed Changes in electrophysiological parameters after open carpal tunnel release
title_short Changes in electrophysiological parameters after open carpal tunnel release
title_sort changes in electrophysiological parameters after open carpal tunnel release
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3544123/
https://www.ncbi.nlm.nih.gov/pubmed/23326777
http://dx.doi.org/10.4103/2277-9175.100151
work_keys_str_mv AT tahririanmohammada changesinelectrophysiologicalparametersafteropencarpaltunnelrelease
AT moghtaderialireza changesinelectrophysiologicalparametersafteropencarpaltunnelrelease
AT aranfarzaneh changesinelectrophysiologicalparametersafteropencarpaltunnelrelease