Cargando…

Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner

BACKGROUND: Positron emission tomography (PET) allows for the measurement of cerebral blood flow (CBF; based on [(15)O]H(2)O) and cerebral metabolic rate of glucose utilization (CMR(glu); based on [(18) F]-2-fluoro-2-deoxy-d-glucose ([(18) F]FDG)). By using kinetic modeling, quantitative CBF and CMR...

Descripción completa

Detalles Bibliográficos
Autores principales: Huisman, Marc C, van Golen, Larissa W, Hoetjes, Nikie J, Greuter, Henri N, Schober, Patrick, Ijzerman, Richard G, Diamant, Michaela, Lammertsma, Adriaan A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3544653/
https://www.ncbi.nlm.nih.gov/pubmed/23168248
http://dx.doi.org/10.1186/2191-219X-2-63
_version_ 1782255818690789376
author Huisman, Marc C
van Golen, Larissa W
Hoetjes, Nikie J
Greuter, Henri N
Schober, Patrick
Ijzerman, Richard G
Diamant, Michaela
Lammertsma, Adriaan A
author_facet Huisman, Marc C
van Golen, Larissa W
Hoetjes, Nikie J
Greuter, Henri N
Schober, Patrick
Ijzerman, Richard G
Diamant, Michaela
Lammertsma, Adriaan A
author_sort Huisman, Marc C
collection PubMed
description BACKGROUND: Positron emission tomography (PET) allows for the measurement of cerebral blood flow (CBF; based on [(15)O]H(2)O) and cerebral metabolic rate of glucose utilization (CMR(glu); based on [(18) F]-2-fluoro-2-deoxy-d-glucose ([(18) F]FDG)). By using kinetic modeling, quantitative CBF and CMR(glu) values can be obtained. However, hardware limitations led to the development of semiquantitive calculation schemes which are still widely used. In this paper, the analysis of CMR(glu) and CBF scans, acquired on a current state-of-the-art PET brain scanner, is presented. In particular, the correspondence between nonlinear as well as linearized methods for the determination of CBF and CMR(glu) is investigated. As a further step towards widespread clinical applicability, the use of an image-derived input function (IDIF) is investigated. METHODS: Thirteen healthy male volunteers were included in this study. Each subject had one scanning session in the fasting state, consisting of a dynamic [(15)O]H(2)O scan and a dynamic [(18) F]FDG PET scan, acquired at a high-resolution research tomograph. Time-activity curves (TACs) were generated for automatically delineated and for manually drawn gray matter (GM) and white matter regions. Input functions were derived using on-line arterial blood sampling (blood sampler derived input function (BSIF)). Additionally, the possibility of using carotid artery IDIFs was investigated. Data were analyzed using nonlinear regression (NLR) of regional TACs and parametric methods. RESULTS: After quality control, 9 CMR(glu) and 11 CBF scans were available for analysis. Average GM CMR(glu) values were 0.33 ± 0.04 μmol/cm(3) per minute, and average CBF values were 0.43 ± 0.09 mL/cm(3) per minute. Good correlation between NLR and parametric CMR(glu) measurements was obtained as well as between NLR and parametric CBF values. For CMR(glu) Patlak linearization, BSIF and IDIF derived results were similar. The use of an IDIF, however, did not provide reliable CBF estimates. CONCLUSION: Nonlinear regression analysis, allowing for the derivation of regional CBF and CMR(glu) values, can be applied to data acquired with high-spatial resolution current state-of-the-art PET brain scanners. Linearized models, applied to the voxel level, resulted in comparable values. CMR(glu) measurements do not require invasive arterial sampling to define the input function. TRIAL REGISTRATION: ClinicalTrials.gov NCT00626080
format Online
Article
Text
id pubmed-3544653
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-35446532013-01-15 Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner Huisman, Marc C van Golen, Larissa W Hoetjes, Nikie J Greuter, Henri N Schober, Patrick Ijzerman, Richard G Diamant, Michaela Lammertsma, Adriaan A EJNMMI Res Original Research BACKGROUND: Positron emission tomography (PET) allows for the measurement of cerebral blood flow (CBF; based on [(15)O]H(2)O) and cerebral metabolic rate of glucose utilization (CMR(glu); based on [(18) F]-2-fluoro-2-deoxy-d-glucose ([(18) F]FDG)). By using kinetic modeling, quantitative CBF and CMR(glu) values can be obtained. However, hardware limitations led to the development of semiquantitive calculation schemes which are still widely used. In this paper, the analysis of CMR(glu) and CBF scans, acquired on a current state-of-the-art PET brain scanner, is presented. In particular, the correspondence between nonlinear as well as linearized methods for the determination of CBF and CMR(glu) is investigated. As a further step towards widespread clinical applicability, the use of an image-derived input function (IDIF) is investigated. METHODS: Thirteen healthy male volunteers were included in this study. Each subject had one scanning session in the fasting state, consisting of a dynamic [(15)O]H(2)O scan and a dynamic [(18) F]FDG PET scan, acquired at a high-resolution research tomograph. Time-activity curves (TACs) were generated for automatically delineated and for manually drawn gray matter (GM) and white matter regions. Input functions were derived using on-line arterial blood sampling (blood sampler derived input function (BSIF)). Additionally, the possibility of using carotid artery IDIFs was investigated. Data were analyzed using nonlinear regression (NLR) of regional TACs and parametric methods. RESULTS: After quality control, 9 CMR(glu) and 11 CBF scans were available for analysis. Average GM CMR(glu) values were 0.33 ± 0.04 μmol/cm(3) per minute, and average CBF values were 0.43 ± 0.09 mL/cm(3) per minute. Good correlation between NLR and parametric CMR(glu) measurements was obtained as well as between NLR and parametric CBF values. For CMR(glu) Patlak linearization, BSIF and IDIF derived results were similar. The use of an IDIF, however, did not provide reliable CBF estimates. CONCLUSION: Nonlinear regression analysis, allowing for the derivation of regional CBF and CMR(glu) values, can be applied to data acquired with high-spatial resolution current state-of-the-art PET brain scanners. Linearized models, applied to the voxel level, resulted in comparable values. CMR(glu) measurements do not require invasive arterial sampling to define the input function. TRIAL REGISTRATION: ClinicalTrials.gov NCT00626080 Springer 2012-11-20 /pmc/articles/PMC3544653/ /pubmed/23168248 http://dx.doi.org/10.1186/2191-219X-2-63 Text en Copyright ©2012 Huisman et al.; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Huisman, Marc C
van Golen, Larissa W
Hoetjes, Nikie J
Greuter, Henri N
Schober, Patrick
Ijzerman, Richard G
Diamant, Michaela
Lammertsma, Adriaan A
Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title_full Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title_fullStr Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title_full_unstemmed Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title_short Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner
title_sort cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution pet scanner
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3544653/
https://www.ncbi.nlm.nih.gov/pubmed/23168248
http://dx.doi.org/10.1186/2191-219X-2-63
work_keys_str_mv AT huismanmarcc cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT vangolenlarissaw cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT hoetjesnikiej cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT greuterhenrin cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT schoberpatrick cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT ijzermanrichardg cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT diamantmichaela cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner
AT lammertsmaadriaana cerebralbloodflowandglucosemetabolisminhealthyvolunteersmeasuredusingahighresolutionpetscanner