Cargando…
Factors having implications on re-retinal detachments after silicone oil removal
AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were fo...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3545127/ https://www.ncbi.nlm.nih.gov/pubmed/23202389 http://dx.doi.org/10.4103/0301-4738.103777 |
_version_ | 1782255877214961664 |
---|---|
author | Nagpal, Manish P Videkar, Rituraj P Nagpal, Kamal M |
author_facet | Nagpal, Manish P Videkar, Rituraj P Nagpal, Kamal M |
author_sort | Nagpal, Manish P |
collection | PubMed |
description | AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were followed up for six months after SOR. They were studied for various factors like encirclage, 360° retinopexy, oil emulsification at the time of SOR, duration of oil tamponade and previous retinal surgeries prior to SOR with their implications on reRD after SOR. RESULTS: Encirclage, 360 laser barrage, both, emulsification of oil (P=0.021, P=0.001, P=0.001, P=0.001, respectively) were associated with lower risks of reRD after SOR whereas duration of tamponade (P=0.980) was not. CONCLUSION: Factors like encirclage, 360 retinopexy, their combination, oil emulsification reduced the incidence of re RD after SOR whereas duration of tamponade does not have statistical significant correlation with re RD after SOR. |
format | Online Article Text |
id | pubmed-3545127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-35451272013-01-16 Factors having implications on re-retinal detachments after silicone oil removal Nagpal, Manish P Videkar, Rituraj P Nagpal, Kamal M Indian J Ophthalmol Original Article AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were followed up for six months after SOR. They were studied for various factors like encirclage, 360° retinopexy, oil emulsification at the time of SOR, duration of oil tamponade and previous retinal surgeries prior to SOR with their implications on reRD after SOR. RESULTS: Encirclage, 360 laser barrage, both, emulsification of oil (P=0.021, P=0.001, P=0.001, P=0.001, respectively) were associated with lower risks of reRD after SOR whereas duration of tamponade (P=0.980) was not. CONCLUSION: Factors like encirclage, 360 retinopexy, their combination, oil emulsification reduced the incidence of re RD after SOR whereas duration of tamponade does not have statistical significant correlation with re RD after SOR. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3545127/ /pubmed/23202389 http://dx.doi.org/10.4103/0301-4738.103777 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Nagpal, Manish P Videkar, Rituraj P Nagpal, Kamal M Factors having implications on re-retinal detachments after silicone oil removal |
title | Factors having implications on re-retinal detachments after silicone oil removal |
title_full | Factors having implications on re-retinal detachments after silicone oil removal |
title_fullStr | Factors having implications on re-retinal detachments after silicone oil removal |
title_full_unstemmed | Factors having implications on re-retinal detachments after silicone oil removal |
title_short | Factors having implications on re-retinal detachments after silicone oil removal |
title_sort | factors having implications on re-retinal detachments after silicone oil removal |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3545127/ https://www.ncbi.nlm.nih.gov/pubmed/23202389 http://dx.doi.org/10.4103/0301-4738.103777 |
work_keys_str_mv | AT nagpalmanishp factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval AT videkarriturajp factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval AT nagpalkamalm factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval |