Cargando…

Factors having implications on re-retinal detachments after silicone oil removal

AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagpal, Manish P, Videkar, Rituraj P, Nagpal, Kamal M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3545127/
https://www.ncbi.nlm.nih.gov/pubmed/23202389
http://dx.doi.org/10.4103/0301-4738.103777
_version_ 1782255877214961664
author Nagpal, Manish P
Videkar, Rituraj P
Nagpal, Kamal M
author_facet Nagpal, Manish P
Videkar, Rituraj P
Nagpal, Kamal M
author_sort Nagpal, Manish P
collection PubMed
description AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were followed up for six months after SOR. They were studied for various factors like encirclage, 360° retinopexy, oil emulsification at the time of SOR, duration of oil tamponade and previous retinal surgeries prior to SOR with their implications on reRD after SOR. RESULTS: Encirclage, 360 laser barrage, both, emulsification of oil (P=0.021, P=0.001, P=0.001, P=0.001, respectively) were associated with lower risks of reRD after SOR whereas duration of tamponade (P=0.980) was not. CONCLUSION: Factors like encirclage, 360 retinopexy, their combination, oil emulsification reduced the incidence of re RD after SOR whereas duration of tamponade does not have statistical significant correlation with re RD after SOR.
format Online
Article
Text
id pubmed-3545127
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-35451272013-01-16 Factors having implications on re-retinal detachments after silicone oil removal Nagpal, Manish P Videkar, Rituraj P Nagpal, Kamal M Indian J Ophthalmol Original Article AIM: To investigate factors having implications on re-retinal detachments (reRD) after silicone oil removal (SOR). MATERIALS AND METHODS: A retroprospective study of 412 eyes (with attached retina after vitrectomy with silicone oil for rhegmatogenous RD) which underwent SOR was conducted and were followed up for six months after SOR. They were studied for various factors like encirclage, 360° retinopexy, oil emulsification at the time of SOR, duration of oil tamponade and previous retinal surgeries prior to SOR with their implications on reRD after SOR. RESULTS: Encirclage, 360 laser barrage, both, emulsification of oil (P=0.021, P=0.001, P=0.001, P=0.001, respectively) were associated with lower risks of reRD after SOR whereas duration of tamponade (P=0.980) was not. CONCLUSION: Factors like encirclage, 360 retinopexy, their combination, oil emulsification reduced the incidence of re RD after SOR whereas duration of tamponade does not have statistical significant correlation with re RD after SOR. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3545127/ /pubmed/23202389 http://dx.doi.org/10.4103/0301-4738.103777 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Nagpal, Manish P
Videkar, Rituraj P
Nagpal, Kamal M
Factors having implications on re-retinal detachments after silicone oil removal
title Factors having implications on re-retinal detachments after silicone oil removal
title_full Factors having implications on re-retinal detachments after silicone oil removal
title_fullStr Factors having implications on re-retinal detachments after silicone oil removal
title_full_unstemmed Factors having implications on re-retinal detachments after silicone oil removal
title_short Factors having implications on re-retinal detachments after silicone oil removal
title_sort factors having implications on re-retinal detachments after silicone oil removal
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3545127/
https://www.ncbi.nlm.nih.gov/pubmed/23202389
http://dx.doi.org/10.4103/0301-4738.103777
work_keys_str_mv AT nagpalmanishp factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval
AT videkarriturajp factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval
AT nagpalkamalm factorshavingimplicationsonreretinaldetachmentsaftersiliconeoilremoval