Cargando…

Reliability and Identification of Aortic Valve Prolapse in the Horse

BACKGROUND: The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. RESULTS: Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for ide...

Descripción completa

Detalles Bibliográficos
Autores principales: Hallowell, Gayle D, Bowen, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3547808/
https://www.ncbi.nlm.nih.gov/pubmed/23311963
http://dx.doi.org/10.1186/1746-6148-9-9
_version_ 1782256232963244032
author Hallowell, Gayle D
Bowen, Mark
author_facet Hallowell, Gayle D
Bowen, Mark
author_sort Hallowell, Gayle D
collection PubMed
description BACKGROUND: The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. RESULTS: Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for identification of AVP (46%; n=13). There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP) examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80) and good agreement between days and observers (kappa >0.6). The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8). Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9), with agreement for the identification of AVP (kappa>0.8). Short axis views of the AoV were used for identification of AVP by fewer respondents (23%), however provided less agreement for the identification of AVP (kappa>0.6) and only adequate agreement with observations made in long axis (kappa>0.5), with AVP being identified more often in short axis (92%) compared to long axis (76%). Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC) of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings of two-dimensional echocardiography. CONCLUSIONS: This study has demonstrated reliable diagnostic criteria for the identification and assessment of AVP that can be used for longitudinal research studies to better define the prevalence and natural history of this condition.
format Online
Article
Text
id pubmed-3547808
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35478082013-01-23 Reliability and Identification of Aortic Valve Prolapse in the Horse Hallowell, Gayle D Bowen, Mark BMC Vet Res Research Article BACKGROUND: The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. RESULTS: Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for identification of AVP (46%; n=13). There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP) examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80) and good agreement between days and observers (kappa >0.6). The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8). Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9), with agreement for the identification of AVP (kappa>0.8). Short axis views of the AoV were used for identification of AVP by fewer respondents (23%), however provided less agreement for the identification of AVP (kappa>0.6) and only adequate agreement with observations made in long axis (kappa>0.5), with AVP being identified more often in short axis (92%) compared to long axis (76%). Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC) of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings of two-dimensional echocardiography. CONCLUSIONS: This study has demonstrated reliable diagnostic criteria for the identification and assessment of AVP that can be used for longitudinal research studies to better define the prevalence and natural history of this condition. BioMed Central 2013-01-11 /pmc/articles/PMC3547808/ /pubmed/23311963 http://dx.doi.org/10.1186/1746-6148-9-9 Text en Copyright ©2013 Hallowell and Bowen; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hallowell, Gayle D
Bowen, Mark
Reliability and Identification of Aortic Valve Prolapse in the Horse
title Reliability and Identification of Aortic Valve Prolapse in the Horse
title_full Reliability and Identification of Aortic Valve Prolapse in the Horse
title_fullStr Reliability and Identification of Aortic Valve Prolapse in the Horse
title_full_unstemmed Reliability and Identification of Aortic Valve Prolapse in the Horse
title_short Reliability and Identification of Aortic Valve Prolapse in the Horse
title_sort reliability and identification of aortic valve prolapse in the horse
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3547808/
https://www.ncbi.nlm.nih.gov/pubmed/23311963
http://dx.doi.org/10.1186/1746-6148-9-9
work_keys_str_mv AT hallowellgayled reliabilityandidentificationofaorticvalveprolapseinthehorse
AT bowenmark reliabilityandidentificationofaorticvalveprolapseinthehorse