Comparison of contact angle hysteresis of different probe liquids on the same solid surface

Advancing and receding contact angles of water, formamide and diiodomethane were measured on 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) layers deposited on three different solid supports—glass, mica and poly(methyl methacrylate). Up to five statistical monolayers were deposited on the surfac...

Descripción completa

Detalles Bibliográficos
Autores principales: Chibowski, Emil, Jurak, Malgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3548097/
https://www.ncbi.nlm.nih.gov/pubmed/23335833
http://dx.doi.org/10.1007/s00396-012-2777-9
_version_ 1782256276146749440
author Chibowski, Emil
Jurak, Malgorzata
author_facet Chibowski, Emil
Jurak, Malgorzata
author_sort Chibowski, Emil
collection PubMed
description Advancing and receding contact angles of water, formamide and diiodomethane were measured on 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) layers deposited on three different solid supports—glass, mica and poly(methyl methacrylate). Up to five statistical monolayers were deposited on the surfaces by spreading DPPC solution. It was found that even on five statistical DPPC monolayers, the hysteresis of a given liquid depends on the kind of solid support. Also on the same solid support the contact angle hysteresis is different for each probe liquid used. The AFM images show that the heights of roughness of the DPPC films cannot be the primary cause of the observed hysteresis because the heights are too small to cause the observed hystereses. It is believed that the hysteresis is due to the liquid film present right behind the three-phase solid surface/liquid drop/gas (vapour) contact line and the presence of Derjaguin pressure. The value of contact angle hysteresis depends on both the solid surface and liquid properties as well as on intermolecular interactions between them.
format Online
Article
Text
id pubmed-3548097
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-35480972013-01-18 Comparison of contact angle hysteresis of different probe liquids on the same solid surface Chibowski, Emil Jurak, Malgorzata Colloid Polym Sci Original Contribution Advancing and receding contact angles of water, formamide and diiodomethane were measured on 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) layers deposited on three different solid supports—glass, mica and poly(methyl methacrylate). Up to five statistical monolayers were deposited on the surfaces by spreading DPPC solution. It was found that even on five statistical DPPC monolayers, the hysteresis of a given liquid depends on the kind of solid support. Also on the same solid support the contact angle hysteresis is different for each probe liquid used. The AFM images show that the heights of roughness of the DPPC films cannot be the primary cause of the observed hysteresis because the heights are too small to cause the observed hystereses. It is believed that the hysteresis is due to the liquid film present right behind the three-phase solid surface/liquid drop/gas (vapour) contact line and the presence of Derjaguin pressure. The value of contact angle hysteresis depends on both the solid surface and liquid properties as well as on intermolecular interactions between them. Springer-Verlag 2012-09-07 2013 /pmc/articles/PMC3548097/ /pubmed/23335833 http://dx.doi.org/10.1007/s00396-012-2777-9 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Contribution
Chibowski, Emil
Jurak, Malgorzata
Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title_full Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title_fullStr Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title_full_unstemmed Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title_short Comparison of contact angle hysteresis of different probe liquids on the same solid surface
title_sort comparison of contact angle hysteresis of different probe liquids on the same solid surface
topic Original Contribution
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3548097/
https://www.ncbi.nlm.nih.gov/pubmed/23335833
http://dx.doi.org/10.1007/s00396-012-2777-9
work_keys_str_mv AT chibowskiemil comparisonofcontactanglehysteresisofdifferentprobeliquidsonthesamesolidsurface
AT jurakmalgorzata comparisonofcontactanglehysteresisofdifferentprobeliquidsonthesamesolidsurface