Cargando…

Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response

BACKGROUND: The analysis of the Auditory Brainstem Response (ABR) is of fundamental importance to the investigation of the auditory system behaviour, though its interpretation has a subjective nature because of the manual process employed in its study and the clinical experience required for its ana...

Descripción completa

Detalles Bibliográficos
Autores principales: Naves, Kheline FP, Pereira, Adriano A, Nasuto, Slawomir J, Russo, Ieda PC, Andrade, Adriano O
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3549898/
https://www.ncbi.nlm.nih.gov/pubmed/23173884
http://dx.doi.org/10.1186/1475-925X-11-86
_version_ 1782256493870972928
author Naves, Kheline FP
Pereira, Adriano A
Nasuto, Slawomir J
Russo, Ieda PC
Andrade, Adriano O
author_facet Naves, Kheline FP
Pereira, Adriano A
Nasuto, Slawomir J
Russo, Ieda PC
Andrade, Adriano O
author_sort Naves, Kheline FP
collection PubMed
description BACKGROUND: The analysis of the Auditory Brainstem Response (ABR) is of fundamental importance to the investigation of the auditory system behaviour, though its interpretation has a subjective nature because of the manual process employed in its study and the clinical experience required for its analysis. When analysing the ABR, clinicians are often interested in the identification of ABR signal components referred to as Jewett waves. In particular, the detection and study of the time when these waves occur (i.e., the wave latency) is a practical tool for the diagnosis of disorders affecting the auditory system. Significant differences in inter-examiner results may lead to completely distinct clinical interpretations of the state of the auditory system. In this context, the aim of this research was to evaluate the inter-examiner agreement and variability in the manual classification of ABR. METHODS: A total of 160 ABR data samples were collected, for four different stimulus intensity (80dBHL, 60dBHL, 40dBHL and 20dBHL), from 10 normal-hearing subjects (5 men and 5 women, from 20 to 52 years). Four examiners with expertise in the manual classification of ABR components participated in the study. The Bland-Altman statistical method was employed for the assessment of inter-examiner agreement and variability. The mean, standard deviation and error for the bias, which is the difference between examiners’ annotations, were estimated for each pair of examiners. Scatter plots and histograms were employed for data visualization and analysis. RESULTS: In most comparisons the differences between examiner’s annotations were below 0.1 ms, which is clinically acceptable. In four cases, it was found a large error and standard deviation (>0.1 ms) that indicate the presence of outliers and thus, discrepancies between examiners. CONCLUSIONS: Our results quantify the inter-examiner agreement and variability of the manual analysis of ABR data, and they also allows for the determination of different patterns of manual ABR analysis.
format Online
Article
Text
id pubmed-3549898
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35498982013-01-24 Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response Naves, Kheline FP Pereira, Adriano A Nasuto, Slawomir J Russo, Ieda PC Andrade, Adriano O Biomed Eng Online Research BACKGROUND: The analysis of the Auditory Brainstem Response (ABR) is of fundamental importance to the investigation of the auditory system behaviour, though its interpretation has a subjective nature because of the manual process employed in its study and the clinical experience required for its analysis. When analysing the ABR, clinicians are often interested in the identification of ABR signal components referred to as Jewett waves. In particular, the detection and study of the time when these waves occur (i.e., the wave latency) is a practical tool for the diagnosis of disorders affecting the auditory system. Significant differences in inter-examiner results may lead to completely distinct clinical interpretations of the state of the auditory system. In this context, the aim of this research was to evaluate the inter-examiner agreement and variability in the manual classification of ABR. METHODS: A total of 160 ABR data samples were collected, for four different stimulus intensity (80dBHL, 60dBHL, 40dBHL and 20dBHL), from 10 normal-hearing subjects (5 men and 5 women, from 20 to 52 years). Four examiners with expertise in the manual classification of ABR components participated in the study. The Bland-Altman statistical method was employed for the assessment of inter-examiner agreement and variability. The mean, standard deviation and error for the bias, which is the difference between examiners’ annotations, were estimated for each pair of examiners. Scatter plots and histograms were employed for data visualization and analysis. RESULTS: In most comparisons the differences between examiner’s annotations were below 0.1 ms, which is clinically acceptable. In four cases, it was found a large error and standard deviation (>0.1 ms) that indicate the presence of outliers and thus, discrepancies between examiners. CONCLUSIONS: Our results quantify the inter-examiner agreement and variability of the manual analysis of ABR data, and they also allows for the determination of different patterns of manual ABR analysis. BioMed Central 2012-11-22 /pmc/articles/PMC3549898/ /pubmed/23173884 http://dx.doi.org/10.1186/1475-925X-11-86 Text en Copyright ©2012 Naves et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Naves, Kheline FP
Pereira, Adriano A
Nasuto, Slawomir J
Russo, Ieda PC
Andrade, Adriano O
Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title_full Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title_fullStr Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title_full_unstemmed Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title_short Assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
title_sort assessment of inter-examiner agreement and variability in the manual classification of auditory brainstem response
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3549898/
https://www.ncbi.nlm.nih.gov/pubmed/23173884
http://dx.doi.org/10.1186/1475-925X-11-86
work_keys_str_mv AT naveskhelinefp assessmentofinterexamineragreementandvariabilityinthemanualclassificationofauditorybrainstemresponse
AT pereiraadrianoa assessmentofinterexamineragreementandvariabilityinthemanualclassificationofauditorybrainstemresponse
AT nasutoslawomirj assessmentofinterexamineragreementandvariabilityinthemanualclassificationofauditorybrainstemresponse
AT russoiedapc assessmentofinterexamineragreementandvariabilityinthemanualclassificationofauditorybrainstemresponse
AT andradeadrianoo assessmentofinterexamineragreementandvariabilityinthemanualclassificationofauditorybrainstemresponse