Cargando…

Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography

Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Brugaletta, Salvatore, Garcia-Garcia, Hector M., Gomez-Lara, Josep, Radu, Maria D., Pawar, Ravindra, Khachabi, Jamal, Bruining, Nico, Sabaté, Manel, Serruys, Patrick W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3550704/
https://www.ncbi.nlm.nih.gov/pubmed/22415543
http://dx.doi.org/10.1007/s10554-012-0030-8
_version_ 1782256529236295680
author Brugaletta, Salvatore
Garcia-Garcia, Hector M.
Gomez-Lara, Josep
Radu, Maria D.
Pawar, Ravindra
Khachabi, Jamal
Bruining, Nico
Sabaté, Manel
Serruys, Patrick W.
author_facet Brugaletta, Salvatore
Garcia-Garcia, Hector M.
Gomez-Lara, Josep
Radu, Maria D.
Pawar, Ravindra
Khachabi, Jamal
Bruining, Nico
Sabaté, Manel
Serruys, Patrick W.
author_sort Brugaletta, Salvatore
collection PubMed
description Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreements has not yet been evaluated. Aim of our study was therefore to evaluate the agreements of this approach, taking into account various zoom settings. 126 struts from 10 selected frames were independently evaluated by four observers using a stepwise approach increasing the zoom setting as following: (1) full view of the lumen (FV), (2) half view of the lumen (HV) and (3) a quarter view of the lumen (QV). Intra- and inter-observer agreements (κ) were assessed. The rate of uncoverage was determined for each strut as the number of times it was defined as uncovered divided by the total number of observations (maximum 12 = 3 zoom settings × 4 analysts) and expressed as percentage. The inter-observer κ values (mean [range]) were 0.32 [0.07–0.63], 0.40 [0.18–0.69] and 0.33 [0.09–0.6], within FV, HV and QV respectively. The intra-observer κ values were 0.60 [0.50–0.70], 0.75 [0.75–0.76] and 0.60 [0.50–0.70], within FV, HV and QV respectively. By increasing zoom setting the κ value of intra-observer agreement was 0.74 [0.58–0.83] (from FV to HV), 0.70 [0.56–0.83] (from HV to QV) and 0.70 [0.37–0.86] (from FV to QV). Overall, the rate of uncoverage was 15.5% [8.3–100%]. The OCT qualitative evaluation of strut coverage has wide inter and intra-observer agreements and is dependent of the zoom setting used during the analysis. A more reproducible approach would be needed to eventually increase the probability to link uncovered struts with clinical events.
format Online
Article
Text
id pubmed-3550704
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-35507042013-01-22 Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography Brugaletta, Salvatore Garcia-Garcia, Hector M. Gomez-Lara, Josep Radu, Maria D. Pawar, Ravindra Khachabi, Jamal Bruining, Nico Sabaté, Manel Serruys, Patrick W. Int J Cardiovasc Imaging Original Paper Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreements has not yet been evaluated. Aim of our study was therefore to evaluate the agreements of this approach, taking into account various zoom settings. 126 struts from 10 selected frames were independently evaluated by four observers using a stepwise approach increasing the zoom setting as following: (1) full view of the lumen (FV), (2) half view of the lumen (HV) and (3) a quarter view of the lumen (QV). Intra- and inter-observer agreements (κ) were assessed. The rate of uncoverage was determined for each strut as the number of times it was defined as uncovered divided by the total number of observations (maximum 12 = 3 zoom settings × 4 analysts) and expressed as percentage. The inter-observer κ values (mean [range]) were 0.32 [0.07–0.63], 0.40 [0.18–0.69] and 0.33 [0.09–0.6], within FV, HV and QV respectively. The intra-observer κ values were 0.60 [0.50–0.70], 0.75 [0.75–0.76] and 0.60 [0.50–0.70], within FV, HV and QV respectively. By increasing zoom setting the κ value of intra-observer agreement was 0.74 [0.58–0.83] (from FV to HV), 0.70 [0.56–0.83] (from HV to QV) and 0.70 [0.37–0.86] (from FV to QV). Overall, the rate of uncoverage was 15.5% [8.3–100%]. The OCT qualitative evaluation of strut coverage has wide inter and intra-observer agreements and is dependent of the zoom setting used during the analysis. A more reproducible approach would be needed to eventually increase the probability to link uncovered struts with clinical events. Springer Netherlands 2012-03-14 2013 /pmc/articles/PMC3550704/ /pubmed/22415543 http://dx.doi.org/10.1007/s10554-012-0030-8 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Paper
Brugaletta, Salvatore
Garcia-Garcia, Hector M.
Gomez-Lara, Josep
Radu, Maria D.
Pawar, Ravindra
Khachabi, Jamal
Bruining, Nico
Sabaté, Manel
Serruys, Patrick W.
Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title_full Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title_fullStr Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title_full_unstemmed Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title_short Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
title_sort reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3550704/
https://www.ncbi.nlm.nih.gov/pubmed/22415543
http://dx.doi.org/10.1007/s10554-012-0030-8
work_keys_str_mv AT brugalettasalvatore reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT garciagarciahectorm reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT gomezlarajosep reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT radumariad reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT pawarravindra reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT khachabijamal reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT bruiningnico reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT sabatemanel reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography
AT serruyspatrickw reproducibilityofqualitativeassessmentofstentstrutscoveragebyopticalcoherencetomography