PURPOSE: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation qu...

Descripción completa

Detalles Bibliográficos
Autores principales: Pujades, Ma Carmen, Camacho, Cristina, Perez-Calatayud, Jose, Richart, José, Gimeno, Jose, Lliso, Françoise, Carmona, Vicente, Ballester, Facundo, Crispín, Vicente, Rodríguez, Silvia, Tormo, Alejandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551356/
https://www.ncbi.nlm.nih.gov/pubmed/23346120
http://dx.doi.org/10.5114/jcb.2011.24817
_version_ 1782256546358493184
author Pujades, Ma Carmen
Camacho, Cristina
Perez-Calatayud, Jose
Richart, José
Gimeno, Jose
Lliso, Françoise
Carmona, Vicente
Ballester, Facundo
Crispín, Vicente
Rodríguez, Silvia
Tormo, Alejandro
author_facet Pujades, Ma Carmen
Camacho, Cristina
Perez-Calatayud, Jose
Richart, José
Gimeno, Jose
Lliso, Françoise
Carmona, Vicente
Ballester, Facundo
Crispín, Vicente
Rodríguez, Silvia
Tormo, Alejandro
author_sort Pujades, Ma Carmen
collection PubMed
description PURPOSE: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. MATERIAL AND METHODS: Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. RESULTS: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. CONCLUSIONS: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification.
format Online
Article
Text
id pubmed-3551356
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-35513562013-01-23 The use of nomograms in LDR-HDR prostate brachytherapy Pujades, Ma Carmen Camacho, Cristina Perez-Calatayud, Jose Richart, José Gimeno, Jose Lliso, Françoise Carmona, Vicente Ballester, Facundo Crispín, Vicente Rodríguez, Silvia Tormo, Alejandro J Contemp Brachytherapy Original Article PURPOSE: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. MATERIAL AND METHODS: Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. RESULTS: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. CONCLUSIONS: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification. Termedia Publishing House 2011-09-30 2011-09 /pmc/articles/PMC3551356/ /pubmed/23346120 http://dx.doi.org/10.5114/jcb.2011.24817 Text en Copyright © 2011 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Pujades, Ma Carmen
Camacho, Cristina
Perez-Calatayud, Jose
Richart, José
Gimeno, Jose
Lliso, Françoise
Carmona, Vicente
Ballester, Facundo
Crispín, Vicente
Rodríguez, Silvia
Tormo, Alejandro
The use of nomograms in LDR-HDR prostate brachytherapy
title The use of nomograms in LDR-HDR prostate brachytherapy
title_full The use of nomograms in LDR-HDR prostate brachytherapy
title_fullStr The use of nomograms in LDR-HDR prostate brachytherapy
title_full_unstemmed The use of nomograms in LDR-HDR prostate brachytherapy
title_short The use of nomograms in LDR-HDR prostate brachytherapy
title_sort use of nomograms in ldr-hdr prostate brachytherapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551356/
https://www.ncbi.nlm.nih.gov/pubmed/23346120
http://dx.doi.org/10.5114/jcb.2011.24817
work_keys_str_mv AT pujadesmacarmen theuseofnomogramsinldrhdrprostatebrachytherapy
AT camachocristina theuseofnomogramsinldrhdrprostatebrachytherapy
AT perezcalatayudjose theuseofnomogramsinldrhdrprostatebrachytherapy
AT richartjose theuseofnomogramsinldrhdrprostatebrachytherapy
AT gimenojose theuseofnomogramsinldrhdrprostatebrachytherapy
AT llisofrancoise theuseofnomogramsinldrhdrprostatebrachytherapy
AT carmonavicente theuseofnomogramsinldrhdrprostatebrachytherapy
AT ballesterfacundo theuseofnomogramsinldrhdrprostatebrachytherapy
AT crispinvicente theuseofnomogramsinldrhdrprostatebrachytherapy
AT rodriguezsilvia theuseofnomogramsinldrhdrprostatebrachytherapy
AT tormoalejandro theuseofnomogramsinldrhdrprostatebrachytherapy
AT pujadesmacarmen useofnomogramsinldrhdrprostatebrachytherapy
AT camachocristina useofnomogramsinldrhdrprostatebrachytherapy
AT perezcalatayudjose useofnomogramsinldrhdrprostatebrachytherapy
AT richartjose useofnomogramsinldrhdrprostatebrachytherapy
AT gimenojose useofnomogramsinldrhdrprostatebrachytherapy
AT llisofrancoise useofnomogramsinldrhdrprostatebrachytherapy
AT carmonavicente useofnomogramsinldrhdrprostatebrachytherapy
AT ballesterfacundo useofnomogramsinldrhdrprostatebrachytherapy
AT crispinvicente useofnomogramsinldrhdrprostatebrachytherapy
AT rodriguezsilvia useofnomogramsinldrhdrprostatebrachytherapy
AT tormoalejandro useofnomogramsinldrhdrprostatebrachytherapy