Cargando…

Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

PURPOSE: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation with local/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate (HDR) brachytherapy (BT) source is reduced to single, double and...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, B. Arunkumar, Singh, Th. Tomcha, Singh, L. Jaichand, Singh, Y. Indibor, Devi, Y. Sobita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551365/
https://www.ncbi.nlm.nih.gov/pubmed/23346127
http://dx.doi.org/10.5114/jcb.2011.26469
_version_ 1782256548483956736
author Sharma, B. Arunkumar
Singh, Th. Tomcha
Singh, L. Jaichand
Singh, Y. Indibor
Devi, Y. Sobita
author_facet Sharma, B. Arunkumar
Singh, Th. Tomcha
Singh, L. Jaichand
Singh, Y. Indibor
Devi, Y. Sobita
author_sort Sharma, B. Arunkumar
collection PubMed
description PURPOSE: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation with local/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate (HDR) brachytherapy (BT) source is reduced to single, double and triple half life in relation to original strength of 10 Ci (∼ 4.081 cGy x m(2) x h(−1)). MATERIAL AND METHODS: A retrospective study was carried out on 52 cervical cancer patients with stage II and III treated with fractionated HDR-BT following external beam radiation therapy (EBRT). International Commission on Radiation Units and Measurement (ICRU) points were defined according to ICRU Report 38, using two orthogonal radiograph images taken by Simulator (Simulix HQ). Biologically effective dose (BED) was calculated at point A for different Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. RESULT: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervical cancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction of source strength, respectively. The probabilities of disease recurrence (local/loco-regional) within 26 months are expected as 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m(2) x h(−1), respectively. The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as 1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. CONCLUSIONS: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 source strength shows reduction in disease free survival according to the increase in treatment time duration per fraction. The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical end point of this study is more significant from double half life reduction of original source strength.
format Online
Article
Text
id pubmed-3551365
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-35513652013-01-23 Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer Sharma, B. Arunkumar Singh, Th. Tomcha Singh, L. Jaichand Singh, Y. Indibor Devi, Y. Sobita J Contemp Brachytherapy Original Article PURPOSE: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation with local/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate (HDR) brachytherapy (BT) source is reduced to single, double and triple half life in relation to original strength of 10 Ci (∼ 4.081 cGy x m(2) x h(−1)). MATERIAL AND METHODS: A retrospective study was carried out on 52 cervical cancer patients with stage II and III treated with fractionated HDR-BT following external beam radiation therapy (EBRT). International Commission on Radiation Units and Measurement (ICRU) points were defined according to ICRU Report 38, using two orthogonal radiograph images taken by Simulator (Simulix HQ). Biologically effective dose (BED) was calculated at point A for different Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. RESULT: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervical cancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction of source strength, respectively. The probabilities of disease recurrence (local/loco-regional) within 26 months are expected as 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m(2) x h(−1), respectively. The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as 1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. CONCLUSIONS: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 source strength shows reduction in disease free survival according to the increase in treatment time duration per fraction. The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical end point of this study is more significant from double half life reduction of original source strength. Termedia Publishing House 2011-12-30 2011-12 /pmc/articles/PMC3551365/ /pubmed/23346127 http://dx.doi.org/10.5114/jcb.2011.26469 Text en Copyright © 2011 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sharma, B. Arunkumar
Singh, Th. Tomcha
Singh, L. Jaichand
Singh, Y. Indibor
Devi, Y. Sobita
Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title_full Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title_fullStr Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title_full_unstemmed Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title_short Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
title_sort biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551365/
https://www.ncbi.nlm.nih.gov/pubmed/23346127
http://dx.doi.org/10.5114/jcb.2011.26469
work_keys_str_mv AT sharmabarunkumar biologicaleffectivedosesintheintracavitaryhighdoseratebrachytherapyofcervicalcancer
AT singhthtomcha biologicaleffectivedosesintheintracavitaryhighdoseratebrachytherapyofcervicalcancer
AT singhljaichand biologicaleffectivedosesintheintracavitaryhighdoseratebrachytherapyofcervicalcancer
AT singhyindibor biologicaleffectivedosesintheintracavitaryhighdoseratebrachytherapyofcervicalcancer
AT deviysobita biologicaleffectivedosesintheintracavitaryhighdoseratebrachytherapyofcervicalcancer