Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia

OBJECTIVES: Validation of choroidal thickness and other biometrics measured by spectral domain optical coherence tomography (SD-OCT) in predicting lacquer cracks formation in highly myopic eyes. METHODS: Patients with a refractive error worse than −8 diopters and moderate myopic maculopathy were rec...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Nan-Kai, Lai, Chi-Chun, Chou, Chai Lin, Chen, Yen-Po, Chuang, Lan-Hsin, Chao, An-Ning, Tseng, Hsiao-Jung, Chang, Chee-Jen, Wu, Wei-Chi, Chen, Kuan-Jen, Tsang, Stephen H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551908/
https://www.ncbi.nlm.nih.gov/pubmed/23349728
http://dx.doi.org/10.1371/journal.pone.0053660
_version_ 1782256639340969984
author Wang, Nan-Kai
Lai, Chi-Chun
Chou, Chai Lin
Chen, Yen-Po
Chuang, Lan-Hsin
Chao, An-Ning
Tseng, Hsiao-Jung
Chang, Chee-Jen
Wu, Wei-Chi
Chen, Kuan-Jen
Tsang, Stephen H.
author_facet Wang, Nan-Kai
Lai, Chi-Chun
Chou, Chai Lin
Chen, Yen-Po
Chuang, Lan-Hsin
Chao, An-Ning
Tseng, Hsiao-Jung
Chang, Chee-Jen
Wu, Wei-Chi
Chen, Kuan-Jen
Tsang, Stephen H.
author_sort Wang, Nan-Kai
collection PubMed
description OBJECTIVES: Validation of choroidal thickness and other biometrics measured by spectral domain optical coherence tomography (SD-OCT) in predicting lacquer cracks formation in highly myopic eyes. METHODS: Patients with a refractive error worse than −8 diopters and moderate myopic maculopathy were recruited into two groups based on the presence or absence of lacquer cracks (36 eyes without and 33 eyes with lacquer cracks). Choroidal thickness, refractive error, and axial length were measured and subjected to receiver operating characteristic curve analysis to identify the optimal cutoff values at predicting lacquer crack formation. The width of the retinal pigment epithelium (RPE), RPE to the inner segment/outer segment line, RPE to the external limiting membrane were also measured and compared to the subfoveal choroidal thickness to assess their relationships as potential markers of lacquer crack formation. RESULTS: Lacquer crack is associated with decreased choroidal thickness, lower best-corrected visual acuity, longer axial length and higher refractive errors. Choroidal thickness has the strongest association with lacquer crack formation versus axial length and refractive error. In eyes with lacquer cracks, stellate lacquer cracks are associated with thinner choroidal thickness compared to eyes with linear lacquer cracks. Subfoveal choroidal thickness less than the width of the retinal pigment epithelium to the inner segment/outer segment line is also associated with lacquer crack formation (sensitivity 78.8%, specificity 88.3%, and accuracy 81.2%). CONCLUSIONS: This study suggests that choroidal thickness and other SD-OCT measurements could be employed clinically to predict the development and severity of lacquer cracks in patients with high myopia.
format Online
Article
Text
id pubmed-3551908
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35519082013-01-24 Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia Wang, Nan-Kai Lai, Chi-Chun Chou, Chai Lin Chen, Yen-Po Chuang, Lan-Hsin Chao, An-Ning Tseng, Hsiao-Jung Chang, Chee-Jen Wu, Wei-Chi Chen, Kuan-Jen Tsang, Stephen H. PLoS One Research Article OBJECTIVES: Validation of choroidal thickness and other biometrics measured by spectral domain optical coherence tomography (SD-OCT) in predicting lacquer cracks formation in highly myopic eyes. METHODS: Patients with a refractive error worse than −8 diopters and moderate myopic maculopathy were recruited into two groups based on the presence or absence of lacquer cracks (36 eyes without and 33 eyes with lacquer cracks). Choroidal thickness, refractive error, and axial length were measured and subjected to receiver operating characteristic curve analysis to identify the optimal cutoff values at predicting lacquer crack formation. The width of the retinal pigment epithelium (RPE), RPE to the inner segment/outer segment line, RPE to the external limiting membrane were also measured and compared to the subfoveal choroidal thickness to assess their relationships as potential markers of lacquer crack formation. RESULTS: Lacquer crack is associated with decreased choroidal thickness, lower best-corrected visual acuity, longer axial length and higher refractive errors. Choroidal thickness has the strongest association with lacquer crack formation versus axial length and refractive error. In eyes with lacquer cracks, stellate lacquer cracks are associated with thinner choroidal thickness compared to eyes with linear lacquer cracks. Subfoveal choroidal thickness less than the width of the retinal pigment epithelium to the inner segment/outer segment line is also associated with lacquer crack formation (sensitivity 78.8%, specificity 88.3%, and accuracy 81.2%). CONCLUSIONS: This study suggests that choroidal thickness and other SD-OCT measurements could be employed clinically to predict the development and severity of lacquer cracks in patients with high myopia. Public Library of Science 2013-01-22 /pmc/articles/PMC3551908/ /pubmed/23349728 http://dx.doi.org/10.1371/journal.pone.0053660 Text en © 2013 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wang, Nan-Kai
Lai, Chi-Chun
Chou, Chai Lin
Chen, Yen-Po
Chuang, Lan-Hsin
Chao, An-Ning
Tseng, Hsiao-Jung
Chang, Chee-Jen
Wu, Wei-Chi
Chen, Kuan-Jen
Tsang, Stephen H.
Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title_full Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title_fullStr Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title_full_unstemmed Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title_short Choroidal Thickness and Biometric Markers for the Screening of Lacquer Cracks in Patients with High Myopia
title_sort choroidal thickness and biometric markers for the screening of lacquer cracks in patients with high myopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551908/
https://www.ncbi.nlm.nih.gov/pubmed/23349728
http://dx.doi.org/10.1371/journal.pone.0053660
work_keys_str_mv AT wangnankai choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT laichichun choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT chouchailin choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT chenyenpo choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT chuanglanhsin choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT chaoanning choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT tsenghsiaojung choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT changcheejen choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT wuweichi choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT chenkuanjen choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia
AT tsangstephenh choroidalthicknessandbiometricmarkersforthescreeningoflacquercracksinpatientswithhighmyopia