Cargando…

A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation

BACKGROUND: Liver donor shortages stimulate the development of strategies that incorporate damaged organs into the donor pool. Herein we present a simplified machine perfusion system without the need for oxygen carriers or temperature control, which we validated in a model of orthotopic liver transp...

Descripción completa

Detalles Bibliográficos
Autores principales: Berendsen, Tim A, Bruinsma, Bote G, Lee, Jungwoo, D’Andrea, Vincent, Liu, Qiang, Izamis, Maria-Louisa, Uygun, Korkut, Yarmush, Martin L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552573/
https://www.ncbi.nlm.nih.gov/pubmed/23369351
http://dx.doi.org/10.1186/2047-1440-1-6
_version_ 1782256689451368448
author Berendsen, Tim A
Bruinsma, Bote G
Lee, Jungwoo
D’Andrea, Vincent
Liu, Qiang
Izamis, Maria-Louisa
Uygun, Korkut
Yarmush, Martin L
author_facet Berendsen, Tim A
Bruinsma, Bote G
Lee, Jungwoo
D’Andrea, Vincent
Liu, Qiang
Izamis, Maria-Louisa
Uygun, Korkut
Yarmush, Martin L
author_sort Berendsen, Tim A
collection PubMed
description BACKGROUND: Liver donor shortages stimulate the development of strategies that incorporate damaged organs into the donor pool. Herein we present a simplified machine perfusion system without the need for oxygen carriers or temperature control, which we validated in a model of orthotopic liver transplantation. METHODS: Rat livers were procured and subnormothermically perfused with supplemented Williams E medium for 3 hours, then transplanted into healthy recipients (Fresh-SNMP group). Outcome was compared with static cold stored organs (UW-Control group). In addition, a rat liver model of donation after cardiac death was adapted using a 60-minute warm ischemic period, after which the grafts were either transplanted directly (WI group) or subnormothermically perfused and transplanted (WI-SNMP group). RESULTS: One-month survival was 100% in the Fresh-SNMP and UW-Control groups, 83.3% in the WI-SNMP group and 0% in the WI group. Clinical parameters, postoperative blood work and histology did not differ significantly between survivors. CONCLUSION: This work demonstrates for the first time in an orthotopic transplantation model that ischemically damaged livers can be regenerated effectively using practical subnormothermic machine perfusion without oxygen carriers.
format Online
Article
Text
id pubmed-3552573
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35525732013-01-29 A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation Berendsen, Tim A Bruinsma, Bote G Lee, Jungwoo D’Andrea, Vincent Liu, Qiang Izamis, Maria-Louisa Uygun, Korkut Yarmush, Martin L Transplant Res Research BACKGROUND: Liver donor shortages stimulate the development of strategies that incorporate damaged organs into the donor pool. Herein we present a simplified machine perfusion system without the need for oxygen carriers or temperature control, which we validated in a model of orthotopic liver transplantation. METHODS: Rat livers were procured and subnormothermically perfused with supplemented Williams E medium for 3 hours, then transplanted into healthy recipients (Fresh-SNMP group). Outcome was compared with static cold stored organs (UW-Control group). In addition, a rat liver model of donation after cardiac death was adapted using a 60-minute warm ischemic period, after which the grafts were either transplanted directly (WI group) or subnormothermically perfused and transplanted (WI-SNMP group). RESULTS: One-month survival was 100% in the Fresh-SNMP and UW-Control groups, 83.3% in the WI-SNMP group and 0% in the WI group. Clinical parameters, postoperative blood work and histology did not differ significantly between survivors. CONCLUSION: This work demonstrates for the first time in an orthotopic transplantation model that ischemically damaged livers can be regenerated effectively using practical subnormothermic machine perfusion without oxygen carriers. BioMed Central 2012-05-09 /pmc/articles/PMC3552573/ /pubmed/23369351 http://dx.doi.org/10.1186/2047-1440-1-6 Text en Copyright ©2012 Berendsen et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Berendsen, Tim A
Bruinsma, Bote G
Lee, Jungwoo
D’Andrea, Vincent
Liu, Qiang
Izamis, Maria-Louisa
Uygun, Korkut
Yarmush, Martin L
A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title_full A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title_fullStr A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title_full_unstemmed A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title_short A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
title_sort simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552573/
https://www.ncbi.nlm.nih.gov/pubmed/23369351
http://dx.doi.org/10.1186/2047-1440-1-6
work_keys_str_mv AT berendsentima asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT bruinsmaboteg asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT leejungwoo asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT dandreavincent asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT liuqiang asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT izamismarialouisa asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT uygunkorkut asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT yarmushmartinl asimplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT berendsentima simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT bruinsmaboteg simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT leejungwoo simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT dandreavincent simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT liuqiang simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT izamismarialouisa simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT uygunkorkut simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation
AT yarmushmartinl simplifiedsubnormothermicmachineperfusionsystemrestoresischemicallydamagedlivergraftsinaratmodeloforthotopiclivertransplantation