Cargando…
A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma
BACKGROUND: Economic viability of treatments for primary open-angle glaucoma (POAG) should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs) most sensitive to differences in visual field and visual functioning...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552875/ https://www.ncbi.nlm.nih.gov/pubmed/22909264 http://dx.doi.org/10.1186/1471-2415-12-43 |
_version_ | 1782256742179012608 |
---|---|
author | Bozzani, Fiammetta Maria Alavi, Yasmene Jofre-Bonet, Mireia Kuper, Hannah |
author_facet | Bozzani, Fiammetta Maria Alavi, Yasmene Jofre-Bonet, Mireia Kuper, Hannah |
author_sort | Bozzani, Fiammetta Maria |
collection | PubMed |
description | BACKGROUND: Economic viability of treatments for primary open-angle glaucoma (POAG) should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs) most sensitive to differences in visual field and visual functioning in patients with POAG. As a secondary objective, the dimensions of generic health-related and vision-related quality of life most affected by progressive vision loss will be identified. METHODS: A total of 132 POAG patients were recruited. Three sets of utility values (EuroQoL EQ-5D, Short Form SF-6D, Time Trade Off) and a measure of perceived visual functioning from the National Eye Institute Visual Function Questionnaire (VFQ-25) were elicited during face-to-face interviews. The sensitivity of UVs to differences in the binocular visual field, visual acuity and visual functioning measures was analysed using non-parametric statistical methods. RESULTS: Median utilities were similar across Integrated Visual Field score quartiles for EQ-5D (P = 0.08) whereas SF-6D and Time-Trade-Off UVs significantly decreased (p = 0.01 and p = 0.001, respectively). The VFQ-25 score varied across Integrated Visual Field and binocular visual acuity groups and was associated with all three UVs (P ≤ 0.001); most of its vision-specific sub-scales were associated with the vision markers. The most affected dimension was driving. A relationship with vision markers was found for the physical component of SF-36 and not for any dimension of EQ-5D. CONCLUSIONS: The Time-Trade-Off was more sensitive than EQ-5D and SF-6D to changes in vision and visual functioning associated with glaucoma progression but could not measure quality of life changes in the mildest disease stages. |
format | Online Article Text |
id | pubmed-3552875 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35528752013-01-28 A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma Bozzani, Fiammetta Maria Alavi, Yasmene Jofre-Bonet, Mireia Kuper, Hannah BMC Ophthalmol Research Article BACKGROUND: Economic viability of treatments for primary open-angle glaucoma (POAG) should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs) most sensitive to differences in visual field and visual functioning in patients with POAG. As a secondary objective, the dimensions of generic health-related and vision-related quality of life most affected by progressive vision loss will be identified. METHODS: A total of 132 POAG patients were recruited. Three sets of utility values (EuroQoL EQ-5D, Short Form SF-6D, Time Trade Off) and a measure of perceived visual functioning from the National Eye Institute Visual Function Questionnaire (VFQ-25) were elicited during face-to-face interviews. The sensitivity of UVs to differences in the binocular visual field, visual acuity and visual functioning measures was analysed using non-parametric statistical methods. RESULTS: Median utilities were similar across Integrated Visual Field score quartiles for EQ-5D (P = 0.08) whereas SF-6D and Time-Trade-Off UVs significantly decreased (p = 0.01 and p = 0.001, respectively). The VFQ-25 score varied across Integrated Visual Field and binocular visual acuity groups and was associated with all three UVs (P ≤ 0.001); most of its vision-specific sub-scales were associated with the vision markers. The most affected dimension was driving. A relationship with vision markers was found for the physical component of SF-36 and not for any dimension of EQ-5D. CONCLUSIONS: The Time-Trade-Off was more sensitive than EQ-5D and SF-6D to changes in vision and visual functioning associated with glaucoma progression but could not measure quality of life changes in the mildest disease stages. BioMed Central 2012-08-21 /pmc/articles/PMC3552875/ /pubmed/22909264 http://dx.doi.org/10.1186/1471-2415-12-43 Text en Copyright ©2012 Bozzani et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bozzani, Fiammetta Maria Alavi, Yasmene Jofre-Bonet, Mireia Kuper, Hannah A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title | A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title_full | A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title_fullStr | A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title_full_unstemmed | A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title_short | A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
title_sort | comparison of the sensitivity of eq-5d, sf-6d and tto utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552875/ https://www.ncbi.nlm.nih.gov/pubmed/22909264 http://dx.doi.org/10.1186/1471-2415-12-43 |
work_keys_str_mv | AT bozzanifiammettamaria acomparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT alaviyasmene acomparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT jofrebonetmireia acomparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT kuperhannah acomparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT bozzanifiammettamaria comparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT alaviyasmene comparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT jofrebonetmireia comparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma AT kuperhannah comparisonofthesensitivityofeq5dsf6dandttoutilityvaluestochangesinvisionandperceivedvisualfunctioninpatientswithprimaryopenangleglaucoma |