Cargando…

Inter- and intra-observer reliability of clinical movement-control tests for marines

BACKGROUND: Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such publ...

Descripción completa

Detalles Bibliográficos
Autores principales: Monnier, Andreas, Heuer, Joachim, Norman, Kjell, Äng, Björn O
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552977/
https://www.ncbi.nlm.nih.gov/pubmed/23273285
http://dx.doi.org/10.1186/1471-2474-13-263
_version_ 1782256757348761600
author Monnier, Andreas
Heuer, Joachim
Norman, Kjell
Äng, Björn O
author_facet Monnier, Andreas
Heuer, Joachim
Norman, Kjell
Äng, Björn O
author_sort Monnier, Andreas
collection PubMed
description BACKGROUND: Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. METHODS: This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. RESULTS: Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. CONCLUSIONS: Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain.
format Online
Article
Text
id pubmed-3552977
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35529772013-01-28 Inter- and intra-observer reliability of clinical movement-control tests for marines Monnier, Andreas Heuer, Joachim Norman, Kjell Äng, Björn O BMC Musculoskelet Disord Research Article BACKGROUND: Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. METHODS: This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. RESULTS: Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. CONCLUSIONS: Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain. BioMed Central 2012-12-29 /pmc/articles/PMC3552977/ /pubmed/23273285 http://dx.doi.org/10.1186/1471-2474-13-263 Text en Copyright ©2012 Monnier et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Monnier, Andreas
Heuer, Joachim
Norman, Kjell
Äng, Björn O
Inter- and intra-observer reliability of clinical movement-control tests for marines
title Inter- and intra-observer reliability of clinical movement-control tests for marines
title_full Inter- and intra-observer reliability of clinical movement-control tests for marines
title_fullStr Inter- and intra-observer reliability of clinical movement-control tests for marines
title_full_unstemmed Inter- and intra-observer reliability of clinical movement-control tests for marines
title_short Inter- and intra-observer reliability of clinical movement-control tests for marines
title_sort inter- and intra-observer reliability of clinical movement-control tests for marines
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3552977/
https://www.ncbi.nlm.nih.gov/pubmed/23273285
http://dx.doi.org/10.1186/1471-2474-13-263
work_keys_str_mv AT monnierandreas interandintraobserverreliabilityofclinicalmovementcontroltestsformarines
AT heuerjoachim interandintraobserverreliabilityofclinicalmovementcontroltestsformarines
AT normankjell interandintraobserverreliabilityofclinicalmovementcontroltestsformarines
AT angbjorno interandintraobserverreliabilityofclinicalmovementcontroltestsformarines