A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports

Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) whic...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Jocelyn, Machen, Heather, Kawaza, Kondwani, Mwanza, Zondiwe, Iniguez, Suzanne, Lang, Hans, Gest, Alfred, Kennedy, Neil, Miros, Robert, Richards-Kortum, Rebecca, Molyneux, Elizabeth, Oden, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3553107/
https://www.ncbi.nlm.nih.gov/pubmed/23372661
http://dx.doi.org/10.1371/journal.pone.0053622
_version_ 1782256785428578304
author Brown, Jocelyn
Machen, Heather
Kawaza, Kondwani
Mwanza, Zondiwe
Iniguez, Suzanne
Lang, Hans
Gest, Alfred
Kennedy, Neil
Miros, Robert
Richards-Kortum, Rebecca
Molyneux, Elizabeth
Oden, Maria
author_facet Brown, Jocelyn
Machen, Heather
Kawaza, Kondwani
Mwanza, Zondiwe
Iniguez, Suzanne
Lang, Hans
Gest, Alfred
Kennedy, Neil
Miros, Robert
Richards-Kortum, Rebecca
Molyneux, Elizabeth
Oden, Maria
author_sort Brown, Jocelyn
collection PubMed
description Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.
format Online
Article
Text
id pubmed-3553107
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35531072013-01-31 A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports Brown, Jocelyn Machen, Heather Kawaza, Kondwani Mwanza, Zondiwe Iniguez, Suzanne Lang, Hans Gest, Alfred Kennedy, Neil Miros, Robert Richards-Kortum, Rebecca Molyneux, Elizabeth Oden, Maria PLoS One Research Article Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. Public Library of Science 2013-01-23 /pmc/articles/PMC3553107/ /pubmed/23372661 http://dx.doi.org/10.1371/journal.pone.0053622 Text en © 2013 Brown et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Brown, Jocelyn
Machen, Heather
Kawaza, Kondwani
Mwanza, Zondiwe
Iniguez, Suzanne
Lang, Hans
Gest, Alfred
Kennedy, Neil
Miros, Robert
Richards-Kortum, Rebecca
Molyneux, Elizabeth
Oden, Maria
A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title_full A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title_fullStr A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title_full_unstemmed A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title_short A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports
title_sort high-value, low-cost bubble continuous positive airway pressure system for low-resource settings: technical assessment and initial case reports
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3553107/
https://www.ncbi.nlm.nih.gov/pubmed/23372661
http://dx.doi.org/10.1371/journal.pone.0053622
work_keys_str_mv AT brownjocelyn ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT machenheather ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT kawazakondwani ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT mwanzazondiwe ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT iniguezsuzanne ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT langhans ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT gestalfred ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT kennedyneil ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT mirosrobert ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT richardskortumrebecca ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT molyneuxelizabeth ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT odenmaria ahighvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT brownjocelyn highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT machenheather highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT kawazakondwani highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT mwanzazondiwe highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT iniguezsuzanne highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT langhans highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT gestalfred highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT kennedyneil highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT mirosrobert highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT richardskortumrebecca highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT molyneuxelizabeth highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports
AT odenmaria highvaluelowcostbubblecontinuouspositiveairwaypressuresystemforlowresourcesettingstechnicalassessmentandinitialcasereports