LOGIC-Insulin Algorithm–Guided Versus Nurse-Directed Blood Glucose Control During Critical Illness: The LOGIC-1 single-center, randomized, controlled clinical trial
OBJECTIVE: Tight blood glucose control (TGC) in critically ill patients is difficult and labor intensive, resulting in poor efficacy of glycemic control and increased hypoglycemia rate. The LOGIC-Insulin computerized algorithm has been developed to assist nurses in titrating insulin to maintain bloo...
Autores principales: | Van Herpe, Tom, Mesotten, Dieter, Wouters, Pieter J., Herbots, Jeroen, Voets, Evy, Buyens, Jo, De Moor, Bart, Van den Berghe, Greet |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3554274/ https://www.ncbi.nlm.nih.gov/pubmed/22961576 http://dx.doi.org/10.2337/dc12-0584 |
Ejemplares similares
-
Software-guided versus nurse-directed blood glucose control in critically ill patients: the LOGIC-2 multicenter randomized controlled clinical trial
por: Dubois, Jasperina, et al.
Publicado: (2017) -
Ingredients for adequate evaluation of blood glucose algorithms as applied to the critically ill
por: Van Herpe, Tom, et al.
Publicado: (2009) -
Glycemic control in critically ill infants and children: achieved quality of control in daily clinical practice in Leuven after a RCT
por: Voets, E, et al.
Publicado: (2011) -
Glycemic penalty index for adequately assessing and comparing different blood glucose control algorithms
por: Van Herpe, Tom, et al.
Publicado: (2008) -
Strict blood glucose control with insulin improves hepatic mitochondrial ultrastructure and function in critical illness
por: Vanhorebeek, I, et al.
Publicado: (2004)