Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report

BACKGROUND: Large health care databases provide a cost-effective data source for observational research in the intensive care unit (ICU) if the coding is valid. The aim of this study was to investigate the accuracy of the recorded coding of ICU admission, mechanical ventilation, and acute dialysis i...

Descripción completa

Detalles Bibliográficos
Autores principales: Blichert-Hansen, Linea, Nielsson, Malene S, Nielsen, Rikke B, Christiansen, Christian F, Nørgaard, Mette
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555432/
https://www.ncbi.nlm.nih.gov/pubmed/23359787
http://dx.doi.org/10.2147/CLEP.S37763
_version_ 1782257039458697216
author Blichert-Hansen, Linea
Nielsson, Malene S
Nielsen, Rikke B
Christiansen, Christian F
Nørgaard, Mette
author_facet Blichert-Hansen, Linea
Nielsson, Malene S
Nielsen, Rikke B
Christiansen, Christian F
Nørgaard, Mette
author_sort Blichert-Hansen, Linea
collection PubMed
description BACKGROUND: Large health care databases provide a cost-effective data source for observational research in the intensive care unit (ICU) if the coding is valid. The aim of this study was to investigate the accuracy of the recorded coding of ICU admission, mechanical ventilation, and acute dialysis in the population-based Danish National Patient Registry (DNPR). METHODS: We conducted the study in the North Denmark Region, including seven ICUs. From the DNPR we selected a total of 150 patients with an ICU admission by the following criteria: (1) 50 patients randomly selected among all patients registered with an ICU admission code, (2) 50 patients with an ICU admission code and a concomitant code for mechanical ventilation, and (3) 50 patients with an ICU admission code and a concomitant code for acute dialysis. Using the medical records as gold standard we estimated the positive predictive value (PPV) for each of the three procedure codes. RESULTS: We located 147 (98%) of the 150 medical records. Of these 147 patients, 141 (95.9%; 95% confidence interval [CI]: 91.8–98.3) had a confirmed ICU admission according to their medical records. Among patients, who were selected only on the coding for ICU admission, the PPV for ICU admission was 87.2% (95% CI: 75.6–94.5). For the mechanical ventilation code, the PPV was 100% (95% CI: 95.1–100). Forty-nine of 50 patients with the coding for acute dialysis received this treatment, corresponding to a PPV of 98.0% (95% CI: 91.0–99.8). CONCLUSION: We found a high PPV for the coding of ICU admission and even higher PPVs for mechanical ventilation, and acute dialysis in the DNPR. The DNPR is a valuable data source for observational studies of ICU patients.
format Online
Article
Text
id pubmed-3555432
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-35554322013-01-28 Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report Blichert-Hansen, Linea Nielsson, Malene S Nielsen, Rikke B Christiansen, Christian F Nørgaard, Mette Clin Epidemiol Original Research BACKGROUND: Large health care databases provide a cost-effective data source for observational research in the intensive care unit (ICU) if the coding is valid. The aim of this study was to investigate the accuracy of the recorded coding of ICU admission, mechanical ventilation, and acute dialysis in the population-based Danish National Patient Registry (DNPR). METHODS: We conducted the study in the North Denmark Region, including seven ICUs. From the DNPR we selected a total of 150 patients with an ICU admission by the following criteria: (1) 50 patients randomly selected among all patients registered with an ICU admission code, (2) 50 patients with an ICU admission code and a concomitant code for mechanical ventilation, and (3) 50 patients with an ICU admission code and a concomitant code for acute dialysis. Using the medical records as gold standard we estimated the positive predictive value (PPV) for each of the three procedure codes. RESULTS: We located 147 (98%) of the 150 medical records. Of these 147 patients, 141 (95.9%; 95% confidence interval [CI]: 91.8–98.3) had a confirmed ICU admission according to their medical records. Among patients, who were selected only on the coding for ICU admission, the PPV for ICU admission was 87.2% (95% CI: 75.6–94.5). For the mechanical ventilation code, the PPV was 100% (95% CI: 95.1–100). Forty-nine of 50 patients with the coding for acute dialysis received this treatment, corresponding to a PPV of 98.0% (95% CI: 91.0–99.8). CONCLUSION: We found a high PPV for the coding of ICU admission and even higher PPVs for mechanical ventilation, and acute dialysis in the DNPR. The DNPR is a valuable data source for observational studies of ICU patients. Dove Medical Press 2013-01-11 /pmc/articles/PMC3555432/ /pubmed/23359787 http://dx.doi.org/10.2147/CLEP.S37763 Text en © 2013 Blichert-Hansen et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Blichert-Hansen, Linea
Nielsson, Malene S
Nielsen, Rikke B
Christiansen, Christian F
Nørgaard, Mette
Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title_full Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title_fullStr Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title_full_unstemmed Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title_short Validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the Danish National Patient Registry: a short report
title_sort validity of the coding for intensive care admission, mechanical ventilation, and acute dialysis in the danish national patient registry: a short report
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555432/
https://www.ncbi.nlm.nih.gov/pubmed/23359787
http://dx.doi.org/10.2147/CLEP.S37763
work_keys_str_mv AT blicherthansenlinea validityofthecodingforintensivecareadmissionmechanicalventilationandacutedialysisinthedanishnationalpatientregistryashortreport
AT nielssonmalenes validityofthecodingforintensivecareadmissionmechanicalventilationandacutedialysisinthedanishnationalpatientregistryashortreport
AT nielsenrikkeb validityofthecodingforintensivecareadmissionmechanicalventilationandacutedialysisinthedanishnationalpatientregistryashortreport
AT christiansenchristianf validityofthecodingforintensivecareadmissionmechanicalventilationandacutedialysisinthedanishnationalpatientregistryashortreport
AT nørgaardmette validityofthecodingforintensivecareadmissionmechanicalventilationandacutedialysisinthedanishnationalpatientregistryashortreport