10-year results of a new low-monomer cement: Follow-up of a randomized RSA study
BACKGROUND AND PURPOSE: The properties and performance of a new low-monomer cement were examined in this prospective randomized, controlled RSA study. 5-year data have already been published, showing no statistically significant differences compared to controls. In the present paper we present the 1...
Autores principales: | Söderlund, Per, Dahl, Jon, Röhrl, Stephan, Nivbrant, Bo, Nilsson, Kjell G |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555461/ https://www.ncbi.nlm.nih.gov/pubmed/23116438 http://dx.doi.org/10.3109/17453674.2012.742392 |
Ejemplares similares
-
No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: An RSA study of 8 patients 10 years after surgery
por: Röhrl, Stephan M, et al.
Publicado: (2012) -
More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: A 10-year follow-up with radiostereometry in 43 hips
por: Dahl, Jon, et al.
Publicado: (2013) -
Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial
por: Lindalen, Einar, et al.
Publicado: (2012) -
Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?: A randomized, controlled RSA study of 60 hips with 10 years of follow-up
por: Weber, Erik, et al.
Publicado: (2017) -
Decreased migration with locally administered bisphosphonate in cemented cup revisions using impaction bone grafting technique: A randomized, controlled study evaluated with RSA and DXA with a 2-year follow-up
por: Zampelis, Vasileios, et al.