Cargando…

Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique

BACKGROUND: Percutaneous vertebroplasty (PV) requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes) during PV can provide simultaneous two-p...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yen-Yao, Huang, Tsung-Jen, Cheng, Chin-Chang, Wu, Meng-Huang, Lee, Ching-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3557160/
https://www.ncbi.nlm.nih.gov/pubmed/23339360
http://dx.doi.org/10.1186/1471-2474-14-38
_version_ 1782257272884297728
author Li, Yen-Yao
Huang, Tsung-Jen
Cheng, Chin-Chang
Wu, Meng-Huang
Lee, Ching-Yu
author_facet Li, Yen-Yao
Huang, Tsung-Jen
Cheng, Chin-Chang
Wu, Meng-Huang
Lee, Ching-Yu
author_sort Li, Yen-Yao
collection PubMed
description BACKGROUND: Percutaneous vertebroplasty (PV) requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes) during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. METHODS: Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients) and one-fluoroscopic technique (13 patients) were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. RESULTS: Mean radiation dose to the patient was 1.97 ± 1.20 mSv (95% CI, 0.71 to 3.23) for the one-fluoroscopic technique group vs. 0.95 ± 0.34 mSv (95% CI, 0.85 to 1.23) for the two-fluoroscopic technique group (P =0.031). Mean radiation dose to the operator was 0.27 ± 0.12 mSv (95% CI, 0.17–0.56) for the one-fluoroscopic technique group vs. 0.25 ± 0.14 mSv (95% CI, 0.06–0.44) for the two-fluoroscopic technique group (P = 0.653). The operative time was significantly different between groups: 47.15 ± 13.48 min (range, 20–75) for the one-fluoroscopic technique group vs. 36.62 ± 8.42 min (range, 21–50) for the two-fluoroscopic technique group (P =0.019). CONCLUSION: Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no significant difference between the two techniques with regards to radiation exposure to the operator.
format Online
Article
Text
id pubmed-3557160
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35571602013-01-31 Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique Li, Yen-Yao Huang, Tsung-Jen Cheng, Chin-Chang Wu, Meng-Huang Lee, Ching-Yu BMC Musculoskelet Disord Research Article BACKGROUND: Percutaneous vertebroplasty (PV) requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes) during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. METHODS: Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients) and one-fluoroscopic technique (13 patients) were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. RESULTS: Mean radiation dose to the patient was 1.97 ± 1.20 mSv (95% CI, 0.71 to 3.23) for the one-fluoroscopic technique group vs. 0.95 ± 0.34 mSv (95% CI, 0.85 to 1.23) for the two-fluoroscopic technique group (P =0.031). Mean radiation dose to the operator was 0.27 ± 0.12 mSv (95% CI, 0.17–0.56) for the one-fluoroscopic technique group vs. 0.25 ± 0.14 mSv (95% CI, 0.06–0.44) for the two-fluoroscopic technique group (P = 0.653). The operative time was significantly different between groups: 47.15 ± 13.48 min (range, 20–75) for the one-fluoroscopic technique group vs. 36.62 ± 8.42 min (range, 21–50) for the two-fluoroscopic technique group (P =0.019). CONCLUSION: Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no significant difference between the two techniques with regards to radiation exposure to the operator. BioMed Central 2013-01-22 /pmc/articles/PMC3557160/ /pubmed/23339360 http://dx.doi.org/10.1186/1471-2474-14-38 Text en Copyright ©2013 Li et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Yen-Yao
Huang, Tsung-Jen
Cheng, Chin-Chang
Wu, Meng-Huang
Lee, Ching-Yu
Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title_full Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title_fullStr Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title_full_unstemmed Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title_short Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
title_sort comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3557160/
https://www.ncbi.nlm.nih.gov/pubmed/23339360
http://dx.doi.org/10.1186/1471-2474-14-38
work_keys_str_mv AT liyenyao comparingradiationexposureduringpercutaneousvertebroplastyusingonevstwofluoroscopictechnique
AT huangtsungjen comparingradiationexposureduringpercutaneousvertebroplastyusingonevstwofluoroscopictechnique
AT chengchinchang comparingradiationexposureduringpercutaneousvertebroplastyusingonevstwofluoroscopictechnique
AT wumenghuang comparingradiationexposureduringpercutaneousvertebroplastyusingonevstwofluoroscopictechnique
AT leechingyu comparingradiationexposureduringpercutaneousvertebroplastyusingonevstwofluoroscopictechnique