Cargando…

Reliability and validity of the Mywellness Key physical activity monitor

BACKGROUND: This study evaluated the reliability and criterion validity of the Mywellness Key accelerometer (MWK) using treadmill protocols and indirect calorimetry. METHODS: Twenty-five participants completed two four-stage 20-minute treadmill protocols while wearing two MWK accelerometers. Reliabi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sieverdes, John C, Wickel, Eric E, Hand, Gregory A, Bergamin, Marco, Moran, Robert R, Blair, Steven N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558248/
https://www.ncbi.nlm.nih.gov/pubmed/23378783
http://dx.doi.org/10.2147/CLEP.S38370
_version_ 1782257400004214784
author Sieverdes, John C
Wickel, Eric E
Hand, Gregory A
Bergamin, Marco
Moran, Robert R
Blair, Steven N
author_facet Sieverdes, John C
Wickel, Eric E
Hand, Gregory A
Bergamin, Marco
Moran, Robert R
Blair, Steven N
author_sort Sieverdes, John C
collection PubMed
description BACKGROUND: This study evaluated the reliability and criterion validity of the Mywellness Key accelerometer (MWK) using treadmill protocols and indirect calorimetry. METHODS: Twenty-five participants completed two four-stage 20-minute treadmill protocols while wearing two MWK accelerometers. Reliability was assessed using raw counts. Validity was assessed by comparing the estimated VO(2) calculated from the MWK with values from respiratory gas exchange. RESULTS: Good overall and point estimates of reliability were found for the MWK (all intraclass correlations > 0.93). Generalizability theory coefficients showed lower values for running speed (0.70) versus walking speed (all > 0.84), with the majority of the overall percentage of variability derived from the participant (68%–88% of the total 100%). Acceptable validity was found overall (Pearson’s r = 0.895–0.902, P < 0.0001), with an overall mean absolute error of 16.22% and a coefficient of variance of 16.92%. Bland-Altman plots showed an overestimation of energy expenditure during the running speed, but total kilocalories were underestimated during the protocol by approximately 10%. CONCLUSION: Good validity was found during light and moderate walking, while running was slightly overestimated. The MWK may be useful for clinicians and researchers interested in promotion or assessment of physical activity.
format Online
Article
Text
id pubmed-3558248
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-35582482013-02-01 Reliability and validity of the Mywellness Key physical activity monitor Sieverdes, John C Wickel, Eric E Hand, Gregory A Bergamin, Marco Moran, Robert R Blair, Steven N Clin Epidemiol Original Research BACKGROUND: This study evaluated the reliability and criterion validity of the Mywellness Key accelerometer (MWK) using treadmill protocols and indirect calorimetry. METHODS: Twenty-five participants completed two four-stage 20-minute treadmill protocols while wearing two MWK accelerometers. Reliability was assessed using raw counts. Validity was assessed by comparing the estimated VO(2) calculated from the MWK with values from respiratory gas exchange. RESULTS: Good overall and point estimates of reliability were found for the MWK (all intraclass correlations > 0.93). Generalizability theory coefficients showed lower values for running speed (0.70) versus walking speed (all > 0.84), with the majority of the overall percentage of variability derived from the participant (68%–88% of the total 100%). Acceptable validity was found overall (Pearson’s r = 0.895–0.902, P < 0.0001), with an overall mean absolute error of 16.22% and a coefficient of variance of 16.92%. Bland-Altman plots showed an overestimation of energy expenditure during the running speed, but total kilocalories were underestimated during the protocol by approximately 10%. CONCLUSION: Good validity was found during light and moderate walking, while running was slightly overestimated. The MWK may be useful for clinicians and researchers interested in promotion or assessment of physical activity. Dove Medical Press 2013-01-25 /pmc/articles/PMC3558248/ /pubmed/23378783 http://dx.doi.org/10.2147/CLEP.S38370 Text en © 2013 Sieverdes et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Sieverdes, John C
Wickel, Eric E
Hand, Gregory A
Bergamin, Marco
Moran, Robert R
Blair, Steven N
Reliability and validity of the Mywellness Key physical activity monitor
title Reliability and validity of the Mywellness Key physical activity monitor
title_full Reliability and validity of the Mywellness Key physical activity monitor
title_fullStr Reliability and validity of the Mywellness Key physical activity monitor
title_full_unstemmed Reliability and validity of the Mywellness Key physical activity monitor
title_short Reliability and validity of the Mywellness Key physical activity monitor
title_sort reliability and validity of the mywellness key physical activity monitor
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558248/
https://www.ncbi.nlm.nih.gov/pubmed/23378783
http://dx.doi.org/10.2147/CLEP.S38370
work_keys_str_mv AT sieverdesjohnc reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor
AT wickelerice reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor
AT handgregorya reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor
AT bergaminmarco reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor
AT moranrobertr reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor
AT blairstevenn reliabilityandvalidityofthemywellnesskeyphysicalactivitymonitor