Cargando…

Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes

Repetitive strain or ‘overuse’ is thought to be a major factor contributing to the development of tendinopathy. The aims of our study were to develop a novel cyclic loading system, and use it to investigate the effect of defined loading conditions on the mechanical properties and gene expression of...

Descripción completa

Detalles Bibliográficos
Autores principales: Legerlotz, K, Jones, G C, Screen, H R C, Riley, G P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558793/
https://www.ncbi.nlm.nih.gov/pubmed/22092479
http://dx.doi.org/10.1111/j.1600-0838.2011.01410.x
_version_ 1782257474821160960
author Legerlotz, K
Jones, G C
Screen, H R C
Riley, G P
author_facet Legerlotz, K
Jones, G C
Screen, H R C
Riley, G P
author_sort Legerlotz, K
collection PubMed
description Repetitive strain or ‘overuse’ is thought to be a major factor contributing to the development of tendinopathy. The aims of our study were to develop a novel cyclic loading system, and use it to investigate the effect of defined loading conditions on the mechanical properties and gene expression of isolated tendon fascicles. Tendon fascicles were dissected from bovine-foot extensors and subjected to cyclic tensile strain (1 Hz) at 30% or 60% of the strain at failure, for 0 h (control), 15 min, 30 min, 1 h, or 5 h. Post loading, a quasi-static test to failure assessed damage. Gene expression at a selected loading regime (1 h at 30% failure strain) was analyzed 6 h post loading by quantitative real-time polymerase chain reaction. Compared with unloaded controls, loading at 30% failure strain took 5 h to lead to a significant decrease in failure stress, whereas loading to 60% led to a significant reduction after 15 min. Loading for 1 h at 30% failure strain did not create significant structural damage, but increased Collagen-1-alpha-chain-1 and interleukin-6 (IL6) expression, suggesting a role of IL6 in tendon adaptation to exercise. Correlating failure properties with fatigue damage provides a method by which changes in gene expression can be associated with different degrees of fatigue damage.
format Online
Article
Text
id pubmed-3558793
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-35587932013-01-31 Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes Legerlotz, K Jones, G C Screen, H R C Riley, G P Scand J Med Sci Sports Original Articles Repetitive strain or ‘overuse’ is thought to be a major factor contributing to the development of tendinopathy. The aims of our study were to develop a novel cyclic loading system, and use it to investigate the effect of defined loading conditions on the mechanical properties and gene expression of isolated tendon fascicles. Tendon fascicles were dissected from bovine-foot extensors and subjected to cyclic tensile strain (1 Hz) at 30% or 60% of the strain at failure, for 0 h (control), 15 min, 30 min, 1 h, or 5 h. Post loading, a quasi-static test to failure assessed damage. Gene expression at a selected loading regime (1 h at 30% failure strain) was analyzed 6 h post loading by quantitative real-time polymerase chain reaction. Compared with unloaded controls, loading at 30% failure strain took 5 h to lead to a significant decrease in failure stress, whereas loading to 60% led to a significant reduction after 15 min. Loading for 1 h at 30% failure strain did not create significant structural damage, but increased Collagen-1-alpha-chain-1 and interleukin-6 (IL6) expression, suggesting a role of IL6 in tendon adaptation to exercise. Correlating failure properties with fatigue damage provides a method by which changes in gene expression can be associated with different degrees of fatigue damage. Blackwell Publishing Ltd 2013-02 2011-11-03 /pmc/articles/PMC3558793/ /pubmed/22092479 http://dx.doi.org/10.1111/j.1600-0838.2011.01410.x Text en Copyright © 2013 John Wiley & Sons A/S http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Original Articles
Legerlotz, K
Jones, G C
Screen, H R C
Riley, G P
Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title_full Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title_fullStr Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title_full_unstemmed Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title_short Cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
title_sort cyclic loading of tendon fascicles using a novel fatigue loading system increases interleukin-6 expression by tenocytes
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558793/
https://www.ncbi.nlm.nih.gov/pubmed/22092479
http://dx.doi.org/10.1111/j.1600-0838.2011.01410.x
work_keys_str_mv AT legerlotzk cyclicloadingoftendonfasciclesusinganovelfatigueloadingsystemincreasesinterleukin6expressionbytenocytes
AT jonesgc cyclicloadingoftendonfasciclesusinganovelfatigueloadingsystemincreasesinterleukin6expressionbytenocytes
AT screenhrc cyclicloadingoftendonfasciclesusinganovelfatigueloadingsystemincreasesinterleukin6expressionbytenocytes
AT rileygp cyclicloadingoftendonfasciclesusinganovelfatigueloadingsystemincreasesinterleukin6expressionbytenocytes