Cargando…
White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study
Age-related white matter lesions (WML) are a risk factor for stroke, cognitive decline, and dementia. Different requirements are imposed on methods for the assessment of WML in clinical settings and for research purposes, but reliability analysis is of major importance. In this study, WML assessment...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3562671/ https://www.ncbi.nlm.nih.gov/pubmed/23401776 http://dx.doi.org/10.1155/2013/198471 |
_version_ | 1782258123481808896 |
---|---|
author | Olsson, Erik Klasson, Niklas Berge, Josef Eckerström, Carl Edman, Åke Malmgren, Helge Wallin, Anders |
author_facet | Olsson, Erik Klasson, Niklas Berge, Josef Eckerström, Carl Edman, Åke Malmgren, Helge Wallin, Anders |
author_sort | Olsson, Erik |
collection | PubMed |
description | Age-related white matter lesions (WML) are a risk factor for stroke, cognitive decline, and dementia. Different requirements are imposed on methods for the assessment of WML in clinical settings and for research purposes, but reliability analysis is of major importance. In this study, WML assessment with three different methods was evaluated. In the Gothenburg mild cognitive impairment study, MRI scans from 152 participants were used to assess WML with the Fazekas visual rating scale on T2 images, a manual volumetric method on FLAIR images, and FreeSurfer volumetry on T1 images. Reliability was acceptable for all three methods. For low WML volumes (2/3 of the patients), reliability was overall lower and nonsignificant for the manual volumetric method. Unreliability in the assessment of patients with low WML with manual volumetry may mainly be due to intensity variation in the FLAIR sequence used; hence, intensity standardization and normalization methods must be used for more accurate assessments. The FreeSurfer segmentations resulted in smaller WML volumes than the volumes acquired with the manual method and showed deviations from visible hypointensities in the T1 images, which quite likely reduces validity. |
format | Online Article Text |
id | pubmed-3562671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-35626712013-02-11 White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study Olsson, Erik Klasson, Niklas Berge, Josef Eckerström, Carl Edman, Åke Malmgren, Helge Wallin, Anders J Aging Res Research Article Age-related white matter lesions (WML) are a risk factor for stroke, cognitive decline, and dementia. Different requirements are imposed on methods for the assessment of WML in clinical settings and for research purposes, but reliability analysis is of major importance. In this study, WML assessment with three different methods was evaluated. In the Gothenburg mild cognitive impairment study, MRI scans from 152 participants were used to assess WML with the Fazekas visual rating scale on T2 images, a manual volumetric method on FLAIR images, and FreeSurfer volumetry on T1 images. Reliability was acceptable for all three methods. For low WML volumes (2/3 of the patients), reliability was overall lower and nonsignificant for the manual volumetric method. Unreliability in the assessment of patients with low WML with manual volumetry may mainly be due to intensity variation in the FLAIR sequence used; hence, intensity standardization and normalization methods must be used for more accurate assessments. The FreeSurfer segmentations resulted in smaller WML volumes than the volumes acquired with the manual method and showed deviations from visible hypointensities in the T1 images, which quite likely reduces validity. Hindawi Publishing Corporation 2013 2013-01-16 /pmc/articles/PMC3562671/ /pubmed/23401776 http://dx.doi.org/10.1155/2013/198471 Text en Copyright © 2013 Erik Olsson et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Olsson, Erik Klasson, Niklas Berge, Josef Eckerström, Carl Edman, Åke Malmgren, Helge Wallin, Anders White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title | White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title_full | White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title_fullStr | White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title_full_unstemmed | White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title_short | White Matter Lesion Assessment in Patients with Cognitive Impairment and Healthy Controls: Reliability Comparisons between Visual Rating, a Manual, and an Automatic Volumetrical MRI Method—The Gothenburg MCI Study |
title_sort | white matter lesion assessment in patients with cognitive impairment and healthy controls: reliability comparisons between visual rating, a manual, and an automatic volumetrical mri method—the gothenburg mci study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3562671/ https://www.ncbi.nlm.nih.gov/pubmed/23401776 http://dx.doi.org/10.1155/2013/198471 |
work_keys_str_mv | AT olssonerik whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT klassonniklas whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT bergejosef whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT eckerstromcarl whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT edmanake whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT malmgrenhelge whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy AT wallinanders whitematterlesionassessmentinpatientswithcognitiveimpairmentandhealthycontrolsreliabilitycomparisonsbetweenvisualratingamanualandanautomaticvolumetricalmrimethodthegothenburgmcistudy |