Cargando…

The interblink interval in normal and dry eye subjects

PURPOSE: Our aim was to extend the concept of blink patterns from average interblink interval (IBI) to other aspects of the distribution of IBI. We hypothesized that this more comprehensive approach would better discriminate between normal and dry eye subjects. METHODS: Blinks were captured over 10...

Descripción completa

Detalles Bibliográficos
Autores principales: Johnston, Patrick R, Rodriguez, John, Lane, Keith J, Ousler, George, Abelson, Mark B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3565584/
https://www.ncbi.nlm.nih.gov/pubmed/23403736
http://dx.doi.org/10.2147/OPTH.S39104
_version_ 1782258462625890304
author Johnston, Patrick R
Rodriguez, John
Lane, Keith J
Ousler, George
Abelson, Mark B
author_facet Johnston, Patrick R
Rodriguez, John
Lane, Keith J
Ousler, George
Abelson, Mark B
author_sort Johnston, Patrick R
collection PubMed
description PURPOSE: Our aim was to extend the concept of blink patterns from average interblink interval (IBI) to other aspects of the distribution of IBI. We hypothesized that this more comprehensive approach would better discriminate between normal and dry eye subjects. METHODS: Blinks were captured over 10 minutes for ten normal and ten dry eye subjects while viewing a standardized televised documentary. Fifty-five blinks were analyzed for each of the 20 subjects. Means, standard deviations, and autocorrelation coefficients were calculated utilizing a single random effects model fit to all data points and a diagnostic model was subsequently fit to predict probability of a subject having dry eye based on these parameters. RESULTS: Mean IBI was 5.97 seconds for normal versus 2.56 seconds for dry eye subjects (ratio: 2.33, P = 0.004). IBI variability was 1.56 times higher in normal subjects (P < 0.001), and the autocorrelation was 1.79 times higher in normal subjects (P = 0.044). With regard to the diagnostic power of these measures, mean IBI was the best dry eye versus normal classifier using receiver operating characteristics (0.85 area under curve (AUC)), followed by the standard deviation (0.75 AUC), and lastly, the autocorrelation (0.63 AUC). All three predictors combined had an AUC of 0.89. Based on this analysis, cutoffs of ≤3.05 seconds for median IBI, and ≤0.73 for the coefficient of variation were chosen to classify dry eye subjects. CONCLUSION: (1) IBI was significantly shorter for dry eye patients performing a visual task compared to normals; (2) there was a greater variability of interblink intervals in normal subjects; and (3) these parameters were useful as diagnostic predictors of dry eye disease. The results of this pilot study merit investigation of IBI parameters on a larger scale study in subjects with dry eye and other ocular surface disorders.
format Online
Article
Text
id pubmed-3565584
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-35655842013-02-12 The interblink interval in normal and dry eye subjects Johnston, Patrick R Rodriguez, John Lane, Keith J Ousler, George Abelson, Mark B Clin Ophthalmol Original Research PURPOSE: Our aim was to extend the concept of blink patterns from average interblink interval (IBI) to other aspects of the distribution of IBI. We hypothesized that this more comprehensive approach would better discriminate between normal and dry eye subjects. METHODS: Blinks were captured over 10 minutes for ten normal and ten dry eye subjects while viewing a standardized televised documentary. Fifty-five blinks were analyzed for each of the 20 subjects. Means, standard deviations, and autocorrelation coefficients were calculated utilizing a single random effects model fit to all data points and a diagnostic model was subsequently fit to predict probability of a subject having dry eye based on these parameters. RESULTS: Mean IBI was 5.97 seconds for normal versus 2.56 seconds for dry eye subjects (ratio: 2.33, P = 0.004). IBI variability was 1.56 times higher in normal subjects (P < 0.001), and the autocorrelation was 1.79 times higher in normal subjects (P = 0.044). With regard to the diagnostic power of these measures, mean IBI was the best dry eye versus normal classifier using receiver operating characteristics (0.85 area under curve (AUC)), followed by the standard deviation (0.75 AUC), and lastly, the autocorrelation (0.63 AUC). All three predictors combined had an AUC of 0.89. Based on this analysis, cutoffs of ≤3.05 seconds for median IBI, and ≤0.73 for the coefficient of variation were chosen to classify dry eye subjects. CONCLUSION: (1) IBI was significantly shorter for dry eye patients performing a visual task compared to normals; (2) there was a greater variability of interblink intervals in normal subjects; and (3) these parameters were useful as diagnostic predictors of dry eye disease. The results of this pilot study merit investigation of IBI parameters on a larger scale study in subjects with dry eye and other ocular surface disorders. Dove Medical Press 2013 2013-02-01 /pmc/articles/PMC3565584/ /pubmed/23403736 http://dx.doi.org/10.2147/OPTH.S39104 Text en © 2013 Johnston et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Johnston, Patrick R
Rodriguez, John
Lane, Keith J
Ousler, George
Abelson, Mark B
The interblink interval in normal and dry eye subjects
title The interblink interval in normal and dry eye subjects
title_full The interblink interval in normal and dry eye subjects
title_fullStr The interblink interval in normal and dry eye subjects
title_full_unstemmed The interblink interval in normal and dry eye subjects
title_short The interblink interval in normal and dry eye subjects
title_sort interblink interval in normal and dry eye subjects
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3565584/
https://www.ncbi.nlm.nih.gov/pubmed/23403736
http://dx.doi.org/10.2147/OPTH.S39104
work_keys_str_mv AT johnstonpatrickr theinterblinkintervalinnormalanddryeyesubjects
AT rodriguezjohn theinterblinkintervalinnormalanddryeyesubjects
AT lanekeithj theinterblinkintervalinnormalanddryeyesubjects
AT ouslergeorge theinterblinkintervalinnormalanddryeyesubjects
AT abelsonmarkb theinterblinkintervalinnormalanddryeyesubjects
AT johnstonpatrickr interblinkintervalinnormalanddryeyesubjects
AT rodriguezjohn interblinkintervalinnormalanddryeyesubjects
AT lanekeithj interblinkintervalinnormalanddryeyesubjects
AT ouslergeorge interblinkintervalinnormalanddryeyesubjects
AT abelsonmarkb interblinkintervalinnormalanddryeyesubjects