Cargando…

Clinical impact of circulating miR-221 in plasma of patients with pancreatic cancer

BACKGROUND: Several recent studies have demonstrated that microRNAs (miRNAs) are stably detectable in plasma/serum. We tested miR-221 and miR-375, which are frequently reported to be highly and poorly expressed in pancreatic cancer (PCa), as candidates for plasma biomarkers in PCa. METHODS: This stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kawaguchi, T, Komatsu, S, Ichikawa, D, Morimura, R, Tsujiura, M, Konishi, H, Takeshita, H, Nagata, H, Arita, T, Hirajima, S, Shiozaki, A, Ikoma, H, Okamoto, K, Ochiai, T, Taniguchi, H, Otsuji, E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3566805/
https://www.ncbi.nlm.nih.gov/pubmed/23329235
http://dx.doi.org/10.1038/bjc.2012.546
Descripción
Sumario:BACKGROUND: Several recent studies have demonstrated that microRNAs (miRNAs) are stably detectable in plasma/serum. We tested miR-221 and miR-375, which are frequently reported to be highly and poorly expressed in pancreatic cancer (PCa), as candidates for plasma biomarkers in PCa. METHODS: This study was divided into three parts: (1) Confirmation of higher miR-221 levels in primary PCa tissue and cell lines than normal pancreatic tissues. (2) Evaluation of plasma miR-221 and miR-375 concentrations by comparing results from 47 consecutive PCa patients and 30 healthy volunteers. (3) Evaluation of the assay for monitoring tumour dynamics in PCa patients. RESULTS: (1) Expression of miR-221 was significantly higher in PCa tissues and cell lines than normal pancreatic tissues. (2) Plasma miR-221 concentrations were significantly higher in PCa patients than that in benign pancreatic tumours (P=0.016) and controls (P<0.0005), while plasma miR-375 concentrations tended to be lower in PCa patients (P=0.064), and the miR-221/miR-375 ratio was significantly higher (P<0.0001) in PCa patients than in controls. (3) Plasma miR-221 concentrations were significantly reduced in postoperative samples (P=0.018). Furthermore, PCa patients with high plasma miR-221 concentrations had significant correlation with distant metastasis (P=0.041), and non-resectable status (P=0.021). CONCLUSION: Plasma miR-221 could be a useful biomarker for cancer detection, monitoring tumour dynamics and predicting malignant outcomes in PCa patients, and may contribute to clinical decision making in PCa treatments.