Cargando…

Ventricular beat detection in single channel electrocardiograms

BACKGROUND: Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators...

Descripción completa

Detalles Bibliográficos
Autores principales: Dotsinsky, Ivan A, Stoyanov, Todor V
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC356927/
https://www.ncbi.nlm.nih.gov/pubmed/14750981
http://dx.doi.org/10.1186/1475-925X-3-3
_version_ 1782121253470994432
author Dotsinsky, Ivan A
Stoyanov, Todor V
author_facet Dotsinsky, Ivan A
Stoyanov, Todor V
author_sort Dotsinsky, Ivan A
collection PubMed
description BACKGROUND: Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators and specialized monitors. METHODS: The developed heuristic algorithm for ventricular beat detection includes two main criteria. The first of them is based on steep edges and sharp peaks evaluation and classifies normal QRS complexes in real time. The second criterion identifies ectopic beats by occurrence of biphasic wave. It is modified to work with a delay of one RR interval in case of long RR intervals. Other algorithm branches classify already detected QRS complexes as ectopic beats if a set of wave parameters is encountered or the ratio of latest two RR intervals RR(i-1)/RR(i )is less than 1:2.5. RESULTS: The algorithm was tested with the AHA and MIT-BIH databases. A sensitivity of 99.04% and a specificity of 99.62% were obtained in detection of 542014 beats. CONCLUSION: The algorithm copes successfully with different complicated cases of single channel ventricular beat detection. It is aimed to simulate to some extent the experience of the cardiologist, rather than to rely on mathematical approaches adopted from the theory of signal analysis. The algorithm is open to improvement, especially in the part concerning the discrimination between normal QRS complexes and ectopic beats.
format Text
id pubmed-356927
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-3569272004-03-05 Ventricular beat detection in single channel electrocardiograms Dotsinsky, Ivan A Stoyanov, Todor V Biomed Eng Online Research BACKGROUND: Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators and specialized monitors. METHODS: The developed heuristic algorithm for ventricular beat detection includes two main criteria. The first of them is based on steep edges and sharp peaks evaluation and classifies normal QRS complexes in real time. The second criterion identifies ectopic beats by occurrence of biphasic wave. It is modified to work with a delay of one RR interval in case of long RR intervals. Other algorithm branches classify already detected QRS complexes as ectopic beats if a set of wave parameters is encountered or the ratio of latest two RR intervals RR(i-1)/RR(i )is less than 1:2.5. RESULTS: The algorithm was tested with the AHA and MIT-BIH databases. A sensitivity of 99.04% and a specificity of 99.62% were obtained in detection of 542014 beats. CONCLUSION: The algorithm copes successfully with different complicated cases of single channel ventricular beat detection. It is aimed to simulate to some extent the experience of the cardiologist, rather than to rely on mathematical approaches adopted from the theory of signal analysis. The algorithm is open to improvement, especially in the part concerning the discrimination between normal QRS complexes and ectopic beats. BioMed Central 2004-01-29 /pmc/articles/PMC356927/ /pubmed/14750981 http://dx.doi.org/10.1186/1475-925X-3-3 Text en Copyright © 2004 Dotsinsky and Stoyanov; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research
Dotsinsky, Ivan A
Stoyanov, Todor V
Ventricular beat detection in single channel electrocardiograms
title Ventricular beat detection in single channel electrocardiograms
title_full Ventricular beat detection in single channel electrocardiograms
title_fullStr Ventricular beat detection in single channel electrocardiograms
title_full_unstemmed Ventricular beat detection in single channel electrocardiograms
title_short Ventricular beat detection in single channel electrocardiograms
title_sort ventricular beat detection in single channel electrocardiograms
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC356927/
https://www.ncbi.nlm.nih.gov/pubmed/14750981
http://dx.doi.org/10.1186/1475-925X-3-3
work_keys_str_mv AT dotsinskyivana ventricularbeatdetectioninsinglechannelelectrocardiograms
AT stoyanovtodorv ventricularbeatdetectioninsinglechannelelectrocardiograms