Cargando…

Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention

Although its use in daily practice is not common, optical coherence tomography (OCT) is a powerful research tool in invasive cardiology. This report describes a hazy angiography image after percutaneous coronary intervention that has been assessed using OCT. Based on the results of the OCT, the pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Carrizo, Sebastian, Salinas, Pablo, Jimenez-Valero, Santiago, Moreno, Raul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3569566/
https://www.ncbi.nlm.nih.gov/pubmed/23407580
http://dx.doi.org/10.4070/kcj.2013.43.1.44
_version_ 1782258918623281152
author Carrizo, Sebastian
Salinas, Pablo
Jimenez-Valero, Santiago
Moreno, Raul
author_facet Carrizo, Sebastian
Salinas, Pablo
Jimenez-Valero, Santiago
Moreno, Raul
author_sort Carrizo, Sebastian
collection PubMed
description Although its use in daily practice is not common, optical coherence tomography (OCT) is a powerful research tool in invasive cardiology. This report describes a hazy angiography image after percutaneous coronary intervention that has been assessed using OCT. Based on the results of the OCT, the patient underwent an elective coronary angioplasty with standard anticoagulation. After implantation of the stent, an intracoronary hazy image was seen on angiography. The use of OCT permitted a correct diagnosis and a successful treatment. This paper provides a discussion of the advantages and disadvantages of OCT, and a comparison with intravascular ultrasound.
format Online
Article
Text
id pubmed-3569566
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-35695662013-02-13 Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention Carrizo, Sebastian Salinas, Pablo Jimenez-Valero, Santiago Moreno, Raul Korean Circ J Case Report Although its use in daily practice is not common, optical coherence tomography (OCT) is a powerful research tool in invasive cardiology. This report describes a hazy angiography image after percutaneous coronary intervention that has been assessed using OCT. Based on the results of the OCT, the patient underwent an elective coronary angioplasty with standard anticoagulation. After implantation of the stent, an intracoronary hazy image was seen on angiography. The use of OCT permitted a correct diagnosis and a successful treatment. This paper provides a discussion of the advantages and disadvantages of OCT, and a comparison with intravascular ultrasound. The Korean Society of Cardiology 2013-01 2013-01-31 /pmc/articles/PMC3569566/ /pubmed/23407580 http://dx.doi.org/10.4070/kcj.2013.43.1.44 Text en Copyright © 2013 The Korean Society of Cardiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Carrizo, Sebastian
Salinas, Pablo
Jimenez-Valero, Santiago
Moreno, Raul
Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title_full Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title_fullStr Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title_full_unstemmed Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title_short Utility of Optical Coherence Tomography to Assess a Hazy Intracoronary Image after Percutaneous Coronary Intervention
title_sort utility of optical coherence tomography to assess a hazy intracoronary image after percutaneous coronary intervention
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3569566/
https://www.ncbi.nlm.nih.gov/pubmed/23407580
http://dx.doi.org/10.4070/kcj.2013.43.1.44
work_keys_str_mv AT carrizosebastian utilityofopticalcoherencetomographytoassessahazyintracoronaryimageafterpercutaneouscoronaryintervention
AT salinaspablo utilityofopticalcoherencetomographytoassessahazyintracoronaryimageafterpercutaneouscoronaryintervention
AT jimenezvalerosantiago utilityofopticalcoherencetomographytoassessahazyintracoronaryimageafterpercutaneouscoronaryintervention
AT morenoraul utilityofopticalcoherencetomographytoassessahazyintracoronaryimageafterpercutaneouscoronaryintervention