Cargando…
Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry
A rapid, sensitive and specific analytical method based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of thalidomide concentration in human plasma. The analyte and internal standard were extracted by liquid-liquid extraction wi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570145/ https://www.ncbi.nlm.nih.gov/pubmed/23404219 http://dx.doi.org/10.3892/etm.2012.847 |
_version_ | 1782259015489683456 |
---|---|
author | BAI, NAN CUI, XIANG-YONG WANG, JIN SUN, CHUN-GUANG MEI, HE-KUN LIANG, BEI-BEI CAI, YUN SONG, XIU-JIE GU, JING-KAI WANG, RUI |
author_facet | BAI, NAN CUI, XIANG-YONG WANG, JIN SUN, CHUN-GUANG MEI, HE-KUN LIANG, BEI-BEI CAI, YUN SONG, XIU-JIE GU, JING-KAI WANG, RUI |
author_sort | BAI, NAN |
collection | PubMed |
description | A rapid, sensitive and specific analytical method based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of thalidomide concentration in human plasma. The analyte and internal standard were extracted by liquid-liquid extraction with ether-dichloromethane (3:2, v/v) and separated on a TC-C(18) column using methanol-10 mM ammonium acetate-formic acid (60:40:0.04, v/v/v) as the mobile phase at a flow rate of 0.9 ml/min. The detection was performed using an API 4000 triple quadrupole mass spectrometer in the positive electrospray ionization (ESI) mode and completed within 3.0 min. The multiple reaction monitoring (MRM) transitions were m/z 259.1→84.0 for the analyte and m/z 195.9→138.9 for temozolomide. The calibration curve exhibited a linear dynamic range of 2–1500 ng/ml (r>0.9991). The intra-and inter-day precisions (as relative standard deviation; RSD) were 6.8–13.5% and 4.3–5.0% respectively and the accuracy (as relative error; RE) was 2.0–3.5%. The recoveries and matrix effects were satisfactory in all the biological matrices examined. This method was successfully used in a pharmacokinetic study of thalidomide in healthy male volunteers receiving an oral administration of a 200-mg dose. |
format | Online Article Text |
id | pubmed-3570145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-35701452013-02-12 Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry BAI, NAN CUI, XIANG-YONG WANG, JIN SUN, CHUN-GUANG MEI, HE-KUN LIANG, BEI-BEI CAI, YUN SONG, XIU-JIE GU, JING-KAI WANG, RUI Exp Ther Med Articles A rapid, sensitive and specific analytical method based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of thalidomide concentration in human plasma. The analyte and internal standard were extracted by liquid-liquid extraction with ether-dichloromethane (3:2, v/v) and separated on a TC-C(18) column using methanol-10 mM ammonium acetate-formic acid (60:40:0.04, v/v/v) as the mobile phase at a flow rate of 0.9 ml/min. The detection was performed using an API 4000 triple quadrupole mass spectrometer in the positive electrospray ionization (ESI) mode and completed within 3.0 min. The multiple reaction monitoring (MRM) transitions were m/z 259.1→84.0 for the analyte and m/z 195.9→138.9 for temozolomide. The calibration curve exhibited a linear dynamic range of 2–1500 ng/ml (r>0.9991). The intra-and inter-day precisions (as relative standard deviation; RSD) were 6.8–13.5% and 4.3–5.0% respectively and the accuracy (as relative error; RE) was 2.0–3.5%. The recoveries and matrix effects were satisfactory in all the biological matrices examined. This method was successfully used in a pharmacokinetic study of thalidomide in healthy male volunteers receiving an oral administration of a 200-mg dose. D.A. Spandidos 2013-02 2012-11-30 /pmc/articles/PMC3570145/ /pubmed/23404219 http://dx.doi.org/10.3892/etm.2012.847 Text en Copyright © 2013, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited. |
spellingShingle | Articles BAI, NAN CUI, XIANG-YONG WANG, JIN SUN, CHUN-GUANG MEI, HE-KUN LIANG, BEI-BEI CAI, YUN SONG, XIU-JIE GU, JING-KAI WANG, RUI Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title | Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title_full | Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title_fullStr | Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title_full_unstemmed | Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title_short | Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
title_sort | determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570145/ https://www.ncbi.nlm.nih.gov/pubmed/23404219 http://dx.doi.org/10.3892/etm.2012.847 |
work_keys_str_mv | AT bainan determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT cuixiangyong determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT wangjin determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT sunchunguang determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT meihekun determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT liangbeibei determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT caiyun determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT songxiujie determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT gujingkai determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry AT wangrui determinationofthalidomideconcentrationinhumanplasmabyliquidchromatographytandemmassspectrometry |