Cargando…

Clinical application of right low-position modified peritoneal dialysis catheterization

The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: REN, WEI, CHEN, WEI, PAN, HUI-XUAN, LAN, LEI, WANG, PENG, HUANG, YE-HUA, KONG, MING, WANG, YAN
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570151/
https://www.ncbi.nlm.nih.gov/pubmed/23404635
http://dx.doi.org/10.3892/etm.2012.808
_version_ 1782259016676671488
author REN, WEI
CHEN, WEI
PAN, HUI-XUAN
LAN, LEI
WANG, PENG
HUANG, YE-HUA
KONG, MING
WANG, YAN
author_facet REN, WEI
CHEN, WEI
PAN, HUI-XUAN
LAN, LEI
WANG, PENG
HUANG, YE-HUA
KONG, MING
WANG, YAN
author_sort REN, WEI
collection PubMed
description The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 patients receiving right low-position modified peritoneal dialysis catheterization (the modified group) from 2006 to 2011 were selected. The inflow time, outflow time, ultrafiltration volume of peritoneal dialysis solution and rate of peritoneal dialysis catheter malposition in the two groups of patients following surgery were compared and analyzed. There were no significant differences of inflow time, outflow time and ultrafiltration volume of the peritoneal dialysis solution between the two groups. In the modified group, no post-operative peritoneal dialysis catheter malposition occurred, therefore the incidence rate was 0. However, 9 patients in the traditional group presented peritoneal dialysis catheter malposition, an incidence rate of 18.75% (9/48). Among them, 6 patients required a second surgery. There was a statistically significant difference in the incidence rate of catheter malposition between the two groups (P<0.01). Right low-position modified peritoneal dialysis catheterization significantly reduced the incidence rate of peritoneal dialysis catheter malposition following peritoneal dialysis, and was shown to be significantly more effective than the traditional peritoneal dialysis catheterization and is therefore worth promoting for clinical use.
format Online
Article
Text
id pubmed-3570151
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-35701512013-02-12 Clinical application of right low-position modified peritoneal dialysis catheterization REN, WEI CHEN, WEI PAN, HUI-XUAN LAN, LEI WANG, PENG HUANG, YE-HUA KONG, MING WANG, YAN Exp Ther Med Articles The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 patients receiving right low-position modified peritoneal dialysis catheterization (the modified group) from 2006 to 2011 were selected. The inflow time, outflow time, ultrafiltration volume of peritoneal dialysis solution and rate of peritoneal dialysis catheter malposition in the two groups of patients following surgery were compared and analyzed. There were no significant differences of inflow time, outflow time and ultrafiltration volume of the peritoneal dialysis solution between the two groups. In the modified group, no post-operative peritoneal dialysis catheter malposition occurred, therefore the incidence rate was 0. However, 9 patients in the traditional group presented peritoneal dialysis catheter malposition, an incidence rate of 18.75% (9/48). Among them, 6 patients required a second surgery. There was a statistically significant difference in the incidence rate of catheter malposition between the two groups (P<0.01). Right low-position modified peritoneal dialysis catheterization significantly reduced the incidence rate of peritoneal dialysis catheter malposition following peritoneal dialysis, and was shown to be significantly more effective than the traditional peritoneal dialysis catheterization and is therefore worth promoting for clinical use. D.A. Spandidos 2013-02 2012-11-12 /pmc/articles/PMC3570151/ /pubmed/23404635 http://dx.doi.org/10.3892/etm.2012.808 Text en Copyright © 2013, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Articles
REN, WEI
CHEN, WEI
PAN, HUI-XUAN
LAN, LEI
WANG, PENG
HUANG, YE-HUA
KONG, MING
WANG, YAN
Clinical application of right low-position modified peritoneal dialysis catheterization
title Clinical application of right low-position modified peritoneal dialysis catheterization
title_full Clinical application of right low-position modified peritoneal dialysis catheterization
title_fullStr Clinical application of right low-position modified peritoneal dialysis catheterization
title_full_unstemmed Clinical application of right low-position modified peritoneal dialysis catheterization
title_short Clinical application of right low-position modified peritoneal dialysis catheterization
title_sort clinical application of right low-position modified peritoneal dialysis catheterization
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570151/
https://www.ncbi.nlm.nih.gov/pubmed/23404635
http://dx.doi.org/10.3892/etm.2012.808
work_keys_str_mv AT renwei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT chenwei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT panhuixuan clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT lanlei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT wangpeng clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT huangyehua clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT kongming clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization
AT wangyan clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization