Cargando…
Clinical application of right low-position modified peritoneal dialysis catheterization
The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 pa...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570151/ https://www.ncbi.nlm.nih.gov/pubmed/23404635 http://dx.doi.org/10.3892/etm.2012.808 |
_version_ | 1782259016676671488 |
---|---|
author | REN, WEI CHEN, WEI PAN, HUI-XUAN LAN, LEI WANG, PENG HUANG, YE-HUA KONG, MING WANG, YAN |
author_facet | REN, WEI CHEN, WEI PAN, HUI-XUAN LAN, LEI WANG, PENG HUANG, YE-HUA KONG, MING WANG, YAN |
author_sort | REN, WEI |
collection | PubMed |
description | The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 patients receiving right low-position modified peritoneal dialysis catheterization (the modified group) from 2006 to 2011 were selected. The inflow time, outflow time, ultrafiltration volume of peritoneal dialysis solution and rate of peritoneal dialysis catheter malposition in the two groups of patients following surgery were compared and analyzed. There were no significant differences of inflow time, outflow time and ultrafiltration volume of the peritoneal dialysis solution between the two groups. In the modified group, no post-operative peritoneal dialysis catheter malposition occurred, therefore the incidence rate was 0. However, 9 patients in the traditional group presented peritoneal dialysis catheter malposition, an incidence rate of 18.75% (9/48). Among them, 6 patients required a second surgery. There was a statistically significant difference in the incidence rate of catheter malposition between the two groups (P<0.01). Right low-position modified peritoneal dialysis catheterization significantly reduced the incidence rate of peritoneal dialysis catheter malposition following peritoneal dialysis, and was shown to be significantly more effective than the traditional peritoneal dialysis catheterization and is therefore worth promoting for clinical use. |
format | Online Article Text |
id | pubmed-3570151 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-35701512013-02-12 Clinical application of right low-position modified peritoneal dialysis catheterization REN, WEI CHEN, WEI PAN, HUI-XUAN LAN, LEI WANG, PENG HUANG, YE-HUA KONG, MING WANG, YAN Exp Ther Med Articles The aim of this study was to investigate peritoneal dialysis catheter malposition following low-position modified peritoneal dialysis catheterization and its clinical application value. A total of 48 patients receiving traditional peritoneal dialysis catheterization (the traditional group) and 95 patients receiving right low-position modified peritoneal dialysis catheterization (the modified group) from 2006 to 2011 were selected. The inflow time, outflow time, ultrafiltration volume of peritoneal dialysis solution and rate of peritoneal dialysis catheter malposition in the two groups of patients following surgery were compared and analyzed. There were no significant differences of inflow time, outflow time and ultrafiltration volume of the peritoneal dialysis solution between the two groups. In the modified group, no post-operative peritoneal dialysis catheter malposition occurred, therefore the incidence rate was 0. However, 9 patients in the traditional group presented peritoneal dialysis catheter malposition, an incidence rate of 18.75% (9/48). Among them, 6 patients required a second surgery. There was a statistically significant difference in the incidence rate of catheter malposition between the two groups (P<0.01). Right low-position modified peritoneal dialysis catheterization significantly reduced the incidence rate of peritoneal dialysis catheter malposition following peritoneal dialysis, and was shown to be significantly more effective than the traditional peritoneal dialysis catheterization and is therefore worth promoting for clinical use. D.A. Spandidos 2013-02 2012-11-12 /pmc/articles/PMC3570151/ /pubmed/23404635 http://dx.doi.org/10.3892/etm.2012.808 Text en Copyright © 2013, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited. |
spellingShingle | Articles REN, WEI CHEN, WEI PAN, HUI-XUAN LAN, LEI WANG, PENG HUANG, YE-HUA KONG, MING WANG, YAN Clinical application of right low-position modified peritoneal dialysis catheterization |
title | Clinical application of right low-position modified peritoneal dialysis catheterization |
title_full | Clinical application of right low-position modified peritoneal dialysis catheterization |
title_fullStr | Clinical application of right low-position modified peritoneal dialysis catheterization |
title_full_unstemmed | Clinical application of right low-position modified peritoneal dialysis catheterization |
title_short | Clinical application of right low-position modified peritoneal dialysis catheterization |
title_sort | clinical application of right low-position modified peritoneal dialysis catheterization |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570151/ https://www.ncbi.nlm.nih.gov/pubmed/23404635 http://dx.doi.org/10.3892/etm.2012.808 |
work_keys_str_mv | AT renwei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT chenwei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT panhuixuan clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT lanlei clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT wangpeng clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT huangyehua clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT kongming clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization AT wangyan clinicalapplicationofrightlowpositionmodifiedperitonealdialysiscatheterization |