Cargando…
Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders
BACKGROUND: Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients’ blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570328/ https://www.ncbi.nlm.nih.gov/pubmed/23294729 http://dx.doi.org/10.1186/1475-2875-12-6 |
_version_ | 1782259048524021760 |
---|---|
author | Xiaodong, Sun Tambo, Ernest Chun, Wei Zhibin, Cheng Yan, Deng Jian, Wang Jiazhi, Wang Xiaonong, Zhou |
author_facet | Xiaodong, Sun Tambo, Ernest Chun, Wei Zhibin, Cheng Yan, Deng Jian, Wang Jiazhi, Wang Xiaonong, Zhou |
author_sort | Xiaodong, Sun |
collection | PubMed |
description | BACKGROUND: Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients’ blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination programme by 2020. The objective of this study is to evaluate the performance of CareStart™ Malaria Pf/Pan RDT kit for the diagnosis of malaria infections in suspected patients. Blood examination by microscopy was taken as gold standard to evaluate CareStart™ kit’s sensitivity, specificity and predictive value and corrected with PCR assay. RESULTS: Overall 126 of 241 (52.28%) malaria cases were detected by microscopy compared to 115 of 241(47.72%) CareStart™ kit and 128 of 241 (53.11%) PCR corrected assay. CareStart™ kit’s sensitivity and specificity for the diagnosis of malaria were 89.68% and 98.26% respectively, compared to standard microscopy, whereas the sensitivity and specificity for falciparum malaria were 88.52% and 98.26%, and for vivax malaria: 90.77% and 100%. The CareStart™ positive predictive values were 98.26% (93.88-99.52%, 95% CI) compared to 100% (96.77-100%, 95% CI) for PCR-corrected, and the negative predictive values of 89.68% (83.15-93.87%, 95% CI) were the same in microscopy as PCR-corrected. The diagnostic accuracy of CareStart™ kit versus microscopy and PCR were 93.78% (89.99-96.19%, 95% CI) and 94.61% (90.99-96.82%, 95% CI) respectively. The likelihood of diagnostic of malaria positive was almost similar between microscopy and CareStart™ kit, with an entropy reduction of 60.0% compared to a weak likelihood of misdiagnosis of 0.10 (0.09-0.12, 95% CI), with an entropy reduction of 36.01%. CONCLUSION: The accuracy of CareStart™ kit is comparable to gold standard microscopy in these areas, it is easy to perform and suitable for cross-border diagnosis and monitoring of local or imported malaria patterns by any local health staff in endemic remotes. |
format | Online Article Text |
id | pubmed-3570328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35703282013-02-13 Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders Xiaodong, Sun Tambo, Ernest Chun, Wei Zhibin, Cheng Yan, Deng Jian, Wang Jiazhi, Wang Xiaonong, Zhou Malar J Research BACKGROUND: Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients’ blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination programme by 2020. The objective of this study is to evaluate the performance of CareStart™ Malaria Pf/Pan RDT kit for the diagnosis of malaria infections in suspected patients. Blood examination by microscopy was taken as gold standard to evaluate CareStart™ kit’s sensitivity, specificity and predictive value and corrected with PCR assay. RESULTS: Overall 126 of 241 (52.28%) malaria cases were detected by microscopy compared to 115 of 241(47.72%) CareStart™ kit and 128 of 241 (53.11%) PCR corrected assay. CareStart™ kit’s sensitivity and specificity for the diagnosis of malaria were 89.68% and 98.26% respectively, compared to standard microscopy, whereas the sensitivity and specificity for falciparum malaria were 88.52% and 98.26%, and for vivax malaria: 90.77% and 100%. The CareStart™ positive predictive values were 98.26% (93.88-99.52%, 95% CI) compared to 100% (96.77-100%, 95% CI) for PCR-corrected, and the negative predictive values of 89.68% (83.15-93.87%, 95% CI) were the same in microscopy as PCR-corrected. The diagnostic accuracy of CareStart™ kit versus microscopy and PCR were 93.78% (89.99-96.19%, 95% CI) and 94.61% (90.99-96.82%, 95% CI) respectively. The likelihood of diagnostic of malaria positive was almost similar between microscopy and CareStart™ kit, with an entropy reduction of 60.0% compared to a weak likelihood of misdiagnosis of 0.10 (0.09-0.12, 95% CI), with an entropy reduction of 36.01%. CONCLUSION: The accuracy of CareStart™ kit is comparable to gold standard microscopy in these areas, it is easy to perform and suitable for cross-border diagnosis and monitoring of local or imported malaria patterns by any local health staff in endemic remotes. BioMed Central 2013-01-07 /pmc/articles/PMC3570328/ /pubmed/23294729 http://dx.doi.org/10.1186/1475-2875-12-6 Text en Copyright ©2013 Xiaodong et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Xiaodong, Sun Tambo, Ernest Chun, Wei Zhibin, Cheng Yan, Deng Jian, Wang Jiazhi, Wang Xiaonong, Zhou Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title | Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title_full | Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title_fullStr | Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title_full_unstemmed | Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title_short | Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders |
title_sort | diagnostic performance of carestart™ malaria hrp2/pldh (pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between china-myanmar endemic borders |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570328/ https://www.ncbi.nlm.nih.gov/pubmed/23294729 http://dx.doi.org/10.1186/1475-2875-12-6 |
work_keys_str_mv | AT xiaodongsun diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT tamboernest diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT chunwei diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT zhibincheng diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT yandeng diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT jianwang diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT jiazhiwang diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders AT xiaonongzhou diagnosticperformanceofcarestartmalariahrp2pldhpfpancombotestversusstandardmicroscopyonfalciparumandvivaxmalariabetweenchinamyanmarendemicborders |