Cargando…
Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis
INTRODUCTION: Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present s...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570974/ https://www.ncbi.nlm.nih.gov/pubmed/23412537 |
_version_ | 1782259132527542272 |
---|---|
author | Tofangchiha, Maryam Adel, Mamak Bakhshi, Mahin Esfehani, Mahsa Nazeman, Pantea Ghorbani Elizeyi, Mojgan Javadi, Amir |
author_facet | Tofangchiha, Maryam Adel, Mamak Bakhshi, Mahin Esfehani, Mahsa Nazeman, Pantea Ghorbani Elizeyi, Mojgan Javadi, Amir |
author_sort | Tofangchiha, Maryam |
collection | PubMed |
description | INTRODUCTION: Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. MATERIAL AND METHODS: In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen’s kappa. RESULTS: Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). CONCLUSION: The type of monitor does not influence diagnosis of vertical root fractures. |
format | Online Article Text |
id | pubmed-3570974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-35709742013-02-14 Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis Tofangchiha, Maryam Adel, Mamak Bakhshi, Mahin Esfehani, Mahsa Nazeman, Pantea Ghorbani Elizeyi, Mojgan Javadi, Amir Iran Endod J Original Article INTRODUCTION: Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. MATERIAL AND METHODS: In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen’s kappa. RESULTS: Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). CONCLUSION: The type of monitor does not influence diagnosis of vertical root fractures. Iranian Center for Endodontic Research 2013-01-20 2013 /pmc/articles/PMC3570974/ /pubmed/23412537 Text en Copyright © 2013, Iranian Endodontic Journal. http://creativecommons.org/licenses/by/3/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Tofangchiha, Maryam Adel, Mamak Bakhshi, Mahin Esfehani, Mahsa Nazeman, Pantea Ghorbani Elizeyi, Mojgan Javadi, Amir Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title | Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title_full | Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title_fullStr | Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title_full_unstemmed | Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title_short | Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis |
title_sort | digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3570974/ https://www.ncbi.nlm.nih.gov/pubmed/23412537 |
work_keys_str_mv | AT tofangchihamaryam digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT adelmamak digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT bakhshimahin digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT esfehanimahsa digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT nazemanpantea digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT ghorbanielizeyimojgan digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis AT javadiamir digitalradiographywithcomputerizedconventionalmonitorscomparedtomedicalmonitorsinverticalrootfracturediagnosis |