Cargando…

Telehealth research

AIMS: Oxleas Telehealth is piloting the effectiveness of remotely monitoring Tier 3 COPD Excessive red alerts taking long time to clinically triage. No standardised method for adjusting thresholds. Anticipated operational issues when upscaling. Oxleas is researching a quantitative method for setting...

Descripción completa

Detalles Bibliográficos
Autores principales: Banerjee, Ombarish, Tanner, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Igitur, Utrecht Publishing & Archiving 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571163/
_version_ 1782259143832240128
author Banerjee, Ombarish
Tanner, Maria
author_facet Banerjee, Ombarish
Tanner, Maria
author_sort Banerjee, Ombarish
collection PubMed
description AIMS: Oxleas Telehealth is piloting the effectiveness of remotely monitoring Tier 3 COPD Excessive red alerts taking long time to clinically triage. No standardised method for adjusting thresholds. Anticipated operational issues when upscaling. Oxleas is researching a quantitative method for setting thresholds by statistically analysing daily variation in patients’ clinical measurements, to differentiate between common place variation in physiology, and special case variation due to ill-health. POTENTIAL BENEFITS: Reduced nurse time spent triaging data and contacting patients with red alerts but well. Freed up nursing time to deliver more community care to patients. Efficient method for threshold setting when upscaling. CYCLE 1 METHOD: For each patient, pulse, oxygen and blood pressure readings were collated for the two preceding months. Arithmetic means were calculated for each. Spread analysis confirmed a bell shaped distribution. Alert thresholds were set three standard deviations from mean for each parameter. Exceptions were made for variation indicating good health (e.g. high oxygen levels). Episodes of abnormal readings were compared to clinical notes to find correlation with episodes of illness. CYCLE 1 RESULT: Correlation revealed 100% sensitivity, where all episodes of illness produced measurements exceeding thresholds. Specificity was poor (85% for oxygen, 60% for pulse and 52% for blood pressure) with numerous false positive readings. Of false positives, 61% occurred due to technical error (mostly faulty batteries or poor user technique). False positives for non-technical reasons were 78% for blood pressure, 57% for pulse and 20% for oxygen. CYCLE 2 METHOD: This was performed to audit technical error. From cycle 1 results, eliminating technical error would improve specificity to 86% for oxygen, 73% for pulse and 63% for blood pressure. Drop down menus were installed on the triage software to code for: 1. Number of abnormal measurements daily. 2. Number of technical errors daily (separate codes for battery error and patient user errors). These were selected daily for each patient. Concurrently, improved systems for battery replacement have been implemented. Patient training has been provided when indicated. Alert thresholds have been updated as in cycle one. CYCLE 2 RESULT (DUE DECEMBER): Early signs of reduced triage time and fewer red alerts will be quantified. CONCLUSIONS: Statistical analysis of measurement variation can provide a highly sensitive method for setting alert thresholds that accurately identifying illness however technical need reduced to improve specificity. The method is most effective for oxygen saturation. Improving effectiveness for other parameters may require improved patient training for equipment use (e.g. activities immediately prior to taking readings etc.). Research cycles using narrower standard deviations to improve specificity are required. If high sensitivity and specificity can be achieved, method can be used to automatically adjust thresholds periodically, reflecting the patient’s most recent clinical status.
format Online
Article
Text
id pubmed-3571163
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Igitur, Utrecht Publishing & Archiving
record_format MEDLINE/PubMed
spelling pubmed-35711632013-04-16 Telehealth research Banerjee, Ombarish Tanner, Maria Int J Integr Care Conference Abstract AIMS: Oxleas Telehealth is piloting the effectiveness of remotely monitoring Tier 3 COPD Excessive red alerts taking long time to clinically triage. No standardised method for adjusting thresholds. Anticipated operational issues when upscaling. Oxleas is researching a quantitative method for setting thresholds by statistically analysing daily variation in patients’ clinical measurements, to differentiate between common place variation in physiology, and special case variation due to ill-health. POTENTIAL BENEFITS: Reduced nurse time spent triaging data and contacting patients with red alerts but well. Freed up nursing time to deliver more community care to patients. Efficient method for threshold setting when upscaling. CYCLE 1 METHOD: For each patient, pulse, oxygen and blood pressure readings were collated for the two preceding months. Arithmetic means were calculated for each. Spread analysis confirmed a bell shaped distribution. Alert thresholds were set three standard deviations from mean for each parameter. Exceptions were made for variation indicating good health (e.g. high oxygen levels). Episodes of abnormal readings were compared to clinical notes to find correlation with episodes of illness. CYCLE 1 RESULT: Correlation revealed 100% sensitivity, where all episodes of illness produced measurements exceeding thresholds. Specificity was poor (85% for oxygen, 60% for pulse and 52% for blood pressure) with numerous false positive readings. Of false positives, 61% occurred due to technical error (mostly faulty batteries or poor user technique). False positives for non-technical reasons were 78% for blood pressure, 57% for pulse and 20% for oxygen. CYCLE 2 METHOD: This was performed to audit technical error. From cycle 1 results, eliminating technical error would improve specificity to 86% for oxygen, 73% for pulse and 63% for blood pressure. Drop down menus were installed on the triage software to code for: 1. Number of abnormal measurements daily. 2. Number of technical errors daily (separate codes for battery error and patient user errors). These were selected daily for each patient. Concurrently, improved systems for battery replacement have been implemented. Patient training has been provided when indicated. Alert thresholds have been updated as in cycle one. CYCLE 2 RESULT (DUE DECEMBER): Early signs of reduced triage time and fewer red alerts will be quantified. CONCLUSIONS: Statistical analysis of measurement variation can provide a highly sensitive method for setting alert thresholds that accurately identifying illness however technical need reduced to improve specificity. The method is most effective for oxygen saturation. Improving effectiveness for other parameters may require improved patient training for equipment use (e.g. activities immediately prior to taking readings etc.). Research cycles using narrower standard deviations to improve specificity are required. If high sensitivity and specificity can be achieved, method can be used to automatically adjust thresholds periodically, reflecting the patient’s most recent clinical status. Igitur, Utrecht Publishing & Archiving 2012-06-15 /pmc/articles/PMC3571163/ Text en Copyright 2012, International Journal of Integrated Care (IJIC) http://creativecommons.org/licenses/by/3.0/ This work is licensed under a (http://creativecommons.org/licenses/by/3.0) Creative Commons Attribution 3.0 Unported License
spellingShingle Conference Abstract
Banerjee, Ombarish
Tanner, Maria
Telehealth research
title Telehealth research
title_full Telehealth research
title_fullStr Telehealth research
title_full_unstemmed Telehealth research
title_short Telehealth research
title_sort telehealth research
topic Conference Abstract
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571163/
work_keys_str_mv AT banerjeeombarish telehealthresearch
AT tannermaria telehealthresearch