Cargando…
Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey
Appliance Load Monitoring (ALM) is essential for energy management solutions, allowing them to obtain appliance-specific energy consumption statistics that can further be used to devise load scheduling strategies for optimal energy utilization. Fine-grained energy monitoring can be achieved by deplo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571813/ https://www.ncbi.nlm.nih.gov/pubmed/23223081 http://dx.doi.org/10.3390/s121216838 |
_version_ | 1782259210584588288 |
---|---|
author | Zoha, Ahmed Gluhak, Alexander Imran, Muhammad Ali Rajasegarar, Sutharshan |
author_facet | Zoha, Ahmed Gluhak, Alexander Imran, Muhammad Ali Rajasegarar, Sutharshan |
author_sort | Zoha, Ahmed |
collection | PubMed |
description | Appliance Load Monitoring (ALM) is essential for energy management solutions, allowing them to obtain appliance-specific energy consumption statistics that can further be used to devise load scheduling strategies for optimal energy utilization. Fine-grained energy monitoring can be achieved by deploying smart power outlets on every device of interest; however it incurs extra hardware cost and installation complexity. Non-Intrusive Load Monitoring (NILM) is an attractive method for energy disaggregation, as it can discern devices from the aggregated data acquired from a single point of measurement. This paper provides a comprehensive overview of NILM system and its associated methods and techniques used for disaggregated energy sensing. We review the state-of-the art load signatures and disaggregation algorithms used for appliance recognition and highlight challenges and future research directions. |
format | Online Article Text |
id | pubmed-3571813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-35718132013-02-19 Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey Zoha, Ahmed Gluhak, Alexander Imran, Muhammad Ali Rajasegarar, Sutharshan Sensors (Basel) Article Appliance Load Monitoring (ALM) is essential for energy management solutions, allowing them to obtain appliance-specific energy consumption statistics that can further be used to devise load scheduling strategies for optimal energy utilization. Fine-grained energy monitoring can be achieved by deploying smart power outlets on every device of interest; however it incurs extra hardware cost and installation complexity. Non-Intrusive Load Monitoring (NILM) is an attractive method for energy disaggregation, as it can discern devices from the aggregated data acquired from a single point of measurement. This paper provides a comprehensive overview of NILM system and its associated methods and techniques used for disaggregated energy sensing. We review the state-of-the art load signatures and disaggregation algorithms used for appliance recognition and highlight challenges and future research directions. Molecular Diversity Preservation International (MDPI) 2012-12-06 /pmc/articles/PMC3571813/ /pubmed/23223081 http://dx.doi.org/10.3390/s121216838 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Zoha, Ahmed Gluhak, Alexander Imran, Muhammad Ali Rajasegarar, Sutharshan Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title | Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title_full | Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title_fullStr | Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title_full_unstemmed | Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title_short | Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey |
title_sort | non-intrusive load monitoring approaches for disaggregated energy sensing: a survey |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571813/ https://www.ncbi.nlm.nih.gov/pubmed/23223081 http://dx.doi.org/10.3390/s121216838 |
work_keys_str_mv | AT zohaahmed nonintrusiveloadmonitoringapproachesfordisaggregatedenergysensingasurvey AT gluhakalexander nonintrusiveloadmonitoringapproachesfordisaggregatedenergysensingasurvey AT imranmuhammadali nonintrusiveloadmonitoringapproachesfordisaggregatedenergysensingasurvey AT rajasegararsutharshan nonintrusiveloadmonitoringapproachesfordisaggregatedenergysensingasurvey |