Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface
A conceptually improved sensor network to monitor the partial pressure of CO(2) in different soil horizons was designed. Consisting of five membrane-based linear sensors (line-sensors) each with 10 m length, the set-up enables us to integrate over the locally fluctuating CO(2) concentrations (typica...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571826/ https://www.ncbi.nlm.nih.gov/pubmed/23235447 http://dx.doi.org/10.3390/s121217058 |
_version_ | 1782259213683130368 |
---|---|
author | Lazik, Detlef Ebert, Sebastian |
author_facet | Lazik, Detlef Ebert, Sebastian |
author_sort | Lazik, Detlef |
collection | PubMed |
description | A conceptually improved sensor network to monitor the partial pressure of CO(2) in different soil horizons was designed. Consisting of five membrane-based linear sensors (line-sensors) each with 10 m length, the set-up enables us to integrate over the locally fluctuating CO(2) concentrations (typically lower 5%(vol)) up to the meter-scale gaining valuable concentration means with a repetition time of about 1 min. Preparatory tests in the laboratory resulted in a unexpected highly increased accuracy of better than 0.03%(vol) with respect to the previously published 0.08%(vol). Thereby, the statistical uncertainties (standard deviations) of the line-sensors and the reference sensor (nondispersive infrared CO(2)-sensor) were close to each other. Whereas the uncertainty of the reference increases with the measurement value, the line-sensors show an inverse uncertainty trend resulting in a comparatively enhanced accuracy for concentrations >1%(vol). Furthermore, a method for in situ maintenance was developed, enabling a proof of sensor quality and its effective calibration without demounting the line-sensors from the soil which would disturb the established structures and ongoing processes. |
format | Online Article Text |
id | pubmed-3571826 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-35718262013-02-19 Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface Lazik, Detlef Ebert, Sebastian Sensors (Basel) Article A conceptually improved sensor network to monitor the partial pressure of CO(2) in different soil horizons was designed. Consisting of five membrane-based linear sensors (line-sensors) each with 10 m length, the set-up enables us to integrate over the locally fluctuating CO(2) concentrations (typically lower 5%(vol)) up to the meter-scale gaining valuable concentration means with a repetition time of about 1 min. Preparatory tests in the laboratory resulted in a unexpected highly increased accuracy of better than 0.03%(vol) with respect to the previously published 0.08%(vol). Thereby, the statistical uncertainties (standard deviations) of the line-sensors and the reference sensor (nondispersive infrared CO(2)-sensor) were close to each other. Whereas the uncertainty of the reference increases with the measurement value, the line-sensors show an inverse uncertainty trend resulting in a comparatively enhanced accuracy for concentrations >1%(vol). Furthermore, a method for in situ maintenance was developed, enabling a proof of sensor quality and its effective calibration without demounting the line-sensors from the soil which would disturb the established structures and ongoing processes. Molecular Diversity Preservation International (MDPI) 2012-12-12 /pmc/articles/PMC3571826/ /pubmed/23235447 http://dx.doi.org/10.3390/s121217058 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Lazik, Detlef Ebert, Sebastian Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title | Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title_full | Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title_fullStr | Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title_full_unstemmed | Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title_short | Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface |
title_sort | improved membrane-based sensor network for reliable gas monitoring in the subsurface |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571826/ https://www.ncbi.nlm.nih.gov/pubmed/23235447 http://dx.doi.org/10.3390/s121217058 |
work_keys_str_mv | AT lazikdetlef improvedmembranebasedsensornetworkforreliablegasmonitoringinthesubsurface AT ebertsebastian improvedmembranebasedsensornetworkforreliablegasmonitoringinthesubsurface |