Cargando…

Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents

A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the se...

Descripción completa

Detalles Bibliográficos
Autores principales: Bataller, Román, Campos, Inmaculada, Laguarda-Miro, Nicolas, Alcañiz, Miguel, Soto, Juan, Martínez-Máñez, Ramón, Gil, Luís, García-Breijo, Eduardo, Ibáñez-Civera, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571853/
https://www.ncbi.nlm.nih.gov/pubmed/23250277
http://dx.doi.org/10.3390/s121217553
_version_ 1782259220070006784
author Bataller, Román
Campos, Inmaculada
Laguarda-Miro, Nicolas
Alcañiz, Miguel
Soto, Juan
Martínez-Máñez, Ramón
Gil, Luís
García-Breijo, Eduardo
Ibáñez-Civera, Javier
author_facet Bataller, Román
Campos, Inmaculada
Laguarda-Miro, Nicolas
Alcañiz, Miguel
Soto, Juan
Martínez-Máñez, Ramón
Gil, Luís
García-Breijo, Eduardo
Ibáñez-Civera, Javier
author_sort Bataller, Román
collection PubMed
description A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the sensing array was characteristic of the presence of glyphosate in buffered water (phosphate buffer 0.1 mol·dm(−3), pH 6.7). Rotating disc electrode (RDE) studies were carried out with Pt, Co and Cu electrodes in water at room temperature and at pH 6.7 using 0.1 mol·dm(−3) of phosphate as a buffer. In the presence of glyphosate, the corrosion current of the Cu and Co electrodes increased significantly, probably due to the formation of Cu(2+) or Co(2+) complexes. The pulse array waveform for the voltammetric tongue was designed by taking into account some of the redox processes observed in the electrochemical studies. The PCA statistical analysis required four dimensions to explain 95% of variance. Moreover, a two-dimensional representation of the two principal components differentiated the water mixtures containing glyphosate. Furthermore, the PLS statistical analyses allowed the creation of a model to correlate the electrochemical response of the electrodes with glyphosate concentrations, even in the presence of potential interferents such as humic acids and Ca(2+). The system offers a PLS prediction model for glyphosate detection with values of 098, −2.3 × 10(−5) and 0.94 for the slope, the intercept and the regression coefficient, respectively, which is in agreement with the good fit between the predicted and measured concentrations. The results suggest the feasibility of this system to help develop electronic tongues for glyphosate detection.
format Online
Article
Text
id pubmed-3571853
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-35718532013-02-19 Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents Bataller, Román Campos, Inmaculada Laguarda-Miro, Nicolas Alcañiz, Miguel Soto, Juan Martínez-Máñez, Ramón Gil, Luís García-Breijo, Eduardo Ibáñez-Civera, Javier Sensors (Basel) Article A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the sensing array was characteristic of the presence of glyphosate in buffered water (phosphate buffer 0.1 mol·dm(−3), pH 6.7). Rotating disc electrode (RDE) studies were carried out with Pt, Co and Cu electrodes in water at room temperature and at pH 6.7 using 0.1 mol·dm(−3) of phosphate as a buffer. In the presence of glyphosate, the corrosion current of the Cu and Co electrodes increased significantly, probably due to the formation of Cu(2+) or Co(2+) complexes. The pulse array waveform for the voltammetric tongue was designed by taking into account some of the redox processes observed in the electrochemical studies. The PCA statistical analysis required four dimensions to explain 95% of variance. Moreover, a two-dimensional representation of the two principal components differentiated the water mixtures containing glyphosate. Furthermore, the PLS statistical analyses allowed the creation of a model to correlate the electrochemical response of the electrodes with glyphosate concentrations, even in the presence of potential interferents such as humic acids and Ca(2+). The system offers a PLS prediction model for glyphosate detection with values of 098, −2.3 × 10(−5) and 0.94 for the slope, the intercept and the regression coefficient, respectively, which is in agreement with the good fit between the predicted and measured concentrations. The results suggest the feasibility of this system to help develop electronic tongues for glyphosate detection. Molecular Diversity Preservation International (MDPI) 2012-12-18 /pmc/articles/PMC3571853/ /pubmed/23250277 http://dx.doi.org/10.3390/s121217553 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Bataller, Román
Campos, Inmaculada
Laguarda-Miro, Nicolas
Alcañiz, Miguel
Soto, Juan
Martínez-Máñez, Ramón
Gil, Luís
García-Breijo, Eduardo
Ibáñez-Civera, Javier
Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title_full Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title_fullStr Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title_full_unstemmed Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title_short Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents
title_sort glyphosate detection by means of a voltammetric electronic tongue and discrimination of potential interferents
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571853/
https://www.ncbi.nlm.nih.gov/pubmed/23250277
http://dx.doi.org/10.3390/s121217553
work_keys_str_mv AT batallerroman glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT camposinmaculada glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT laguardamironicolas glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT alcanizmiguel glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT sotojuan glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT martinezmanezramon glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT gilluis glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT garciabreijoeduardo glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents
AT ibanezciverajavier glyphosatedetectionbymeansofavoltammetricelectronictongueanddiscriminationofpotentialinterferents