Cargando…
Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT
BACKGROUND. Treatment planning for head and neck (H&N) cancer is complex due to the number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant OAR must also be taken into consideration. Intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiothe...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Versita, Warsaw
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3572895/ https://www.ncbi.nlm.nih.gov/pubmed/23412761 http://dx.doi.org/10.2478/v10019-012-0050-y |
_version_ | 1782259365395300352 |
---|---|
author | Peszynska-Piorun, Magdalena Malicki, Julian Golusinski, Wojciech |
author_facet | Peszynska-Piorun, Magdalena Malicki, Julian Golusinski, Wojciech |
author_sort | Peszynska-Piorun, Magdalena |
collection | PubMed |
description | BACKGROUND. Treatment planning for head and neck (H&N) cancer is complex due to the number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant OAR must also be taken into consideration. Intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) are both common H&N treatment techniques with very different planning approaches. Although IMRT allows a better dose conformity in PTV, there is much less evidence as to which technique less dose to OAR is delivered. Therefore, the aim of the study was to compare IMRT to 3D-CRT treatment in terms of dose distribution to OAR in H&N cancer. PATIENTS AND METHODS. This was a prospective study of a series of 25 patients diagnosed with stage cT(3–4)N(0–2) laryngeal cancer. All patients underwent total laryngectomy and bilateral selective neck dissections. In all cases, patients were treated with IMRT, although a 3D-CRT treatment plan was also developed for the comparative analysis. To compare doses to specific OAR, we developed a new comparative index based on sub-volumes. RESULTS. In general, IMRT appears to deliver comparable or greater doses to OAR, although the only significant differences were found in the cerebellum, in which 3D-CRT was found to better spare the organ. CONCLUSIONS. Organs located outside of the IMRT beam (i.e., distant organs) are generally thought to be well-spared. However, the results of this study show that, in the case of the cerebellum, this was not true. This finding suggests that larger studies should be performed to understand the effects of IMRT on distant tissues. Anthropomorphic phantom studies could also confirm these results. |
format | Online Article Text |
id | pubmed-3572895 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Versita, Warsaw |
record_format | MEDLINE/PubMed |
spelling | pubmed-35728952013-02-14 Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT Peszynska-Piorun, Magdalena Malicki, Julian Golusinski, Wojciech Radiol Oncol Research Article BACKGROUND. Treatment planning for head and neck (H&N) cancer is complex due to the number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant OAR must also be taken into consideration. Intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) are both common H&N treatment techniques with very different planning approaches. Although IMRT allows a better dose conformity in PTV, there is much less evidence as to which technique less dose to OAR is delivered. Therefore, the aim of the study was to compare IMRT to 3D-CRT treatment in terms of dose distribution to OAR in H&N cancer. PATIENTS AND METHODS. This was a prospective study of a series of 25 patients diagnosed with stage cT(3–4)N(0–2) laryngeal cancer. All patients underwent total laryngectomy and bilateral selective neck dissections. In all cases, patients were treated with IMRT, although a 3D-CRT treatment plan was also developed for the comparative analysis. To compare doses to specific OAR, we developed a new comparative index based on sub-volumes. RESULTS. In general, IMRT appears to deliver comparable or greater doses to OAR, although the only significant differences were found in the cerebellum, in which 3D-CRT was found to better spare the organ. CONCLUSIONS. Organs located outside of the IMRT beam (i.e., distant organs) are generally thought to be well-spared. However, the results of this study show that, in the case of the cerebellum, this was not true. This finding suggests that larger studies should be performed to understand the effects of IMRT on distant tissues. Anthropomorphic phantom studies could also confirm these results. Versita, Warsaw 2012-11-09 /pmc/articles/PMC3572895/ /pubmed/23412761 http://dx.doi.org/10.2478/v10019-012-0050-y Text en Copyright © by Association of Radiology & Oncology http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Research Article Peszynska-Piorun, Magdalena Malicki, Julian Golusinski, Wojciech Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title | Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title_full | Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title_fullStr | Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title_full_unstemmed | Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title_short | Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT |
title_sort | doses in organs at risk during head and neck radiotherapy using imrt and 3d-crt |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3572895/ https://www.ncbi.nlm.nih.gov/pubmed/23412761 http://dx.doi.org/10.2478/v10019-012-0050-y |
work_keys_str_mv | AT peszynskapiorunmagdalena dosesinorgansatriskduringheadandneckradiotherapyusingimrtand3dcrt AT malickijulian dosesinorgansatriskduringheadandneckradiotherapyusingimrtand3dcrt AT golusinskiwojciech dosesinorgansatriskduringheadandneckradiotherapyusingimrtand3dcrt |