Cargando…

Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom

Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8–20...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiaofeng, Webb, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574670/
https://www.ncbi.nlm.nih.gov/pubmed/23262479
http://dx.doi.org/10.3390/s130100152
_version_ 1782259611143766016
author Zhang, Xiaofeng
Webb, Andrew
author_facet Zhang, Xiaofeng
Webb, Andrew
author_sort Zhang, Xiaofeng
collection PubMed
description Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8–20 microliters. The non-linear relation between the maximum detectable depth and the magnitude of changes in the absorption coefficient conform well with the Born approximation to the diffusion equation. The minimal detectable changes in the reduced scattering coefficient measured in terms of the phase signal were found to be approximately twice as large as that of the absorption coefficient using the AC signal for the same volume and at the same depth. The phase delay, which can be used to quantify the fast neuronal optical response in the human brain, showed a linear dependence on the reciprocal of the reduced scattering coefficient, as predicted by the Rytov approximation.
format Online
Article
Text
id pubmed-3574670
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-35746702013-02-25 Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom Zhang, Xiaofeng Webb, Andrew Sensors (Basel) Article Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8–20 microliters. The non-linear relation between the maximum detectable depth and the magnitude of changes in the absorption coefficient conform well with the Born approximation to the diffusion equation. The minimal detectable changes in the reduced scattering coefficient measured in terms of the phase signal were found to be approximately twice as large as that of the absorption coefficient using the AC signal for the same volume and at the same depth. The phase delay, which can be used to quantify the fast neuronal optical response in the human brain, showed a linear dependence on the reciprocal of the reduced scattering coefficient, as predicted by the Rytov approximation. MDPI 2012-12-24 /pmc/articles/PMC3574670/ /pubmed/23262479 http://dx.doi.org/10.3390/s130100152 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Zhang, Xiaofeng
Webb, Andrew
Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title_full Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title_fullStr Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title_full_unstemmed Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title_short Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
title_sort detectability of absorption and reduced scattering coefficients in frequency-domain measurements using a realistic head phantom
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574670/
https://www.ncbi.nlm.nih.gov/pubmed/23262479
http://dx.doi.org/10.3390/s130100152
work_keys_str_mv AT zhangxiaofeng detectabilityofabsorptionandreducedscatteringcoefficientsinfrequencydomainmeasurementsusingarealisticheadphantom
AT webbandrew detectabilityofabsorptionandreducedscatteringcoefficientsinfrequencydomainmeasurementsusingarealisticheadphantom