Cargando…

Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications

Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems h...

Descripción completa

Detalles Bibliográficos
Autores principales: Kottmann, Jonas, Grob, Urs, Rey, Julien M., Sigrist, Markus W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574689/
https://www.ncbi.nlm.nih.gov/pubmed/23282584
http://dx.doi.org/10.3390/s130100535
_version_ 1782259615643205632
author Kottmann, Jonas
Grob, Urs
Rey, Julien M.
Sigrist, Markus W.
author_facet Kottmann, Jonas
Grob, Urs
Rey, Julien M.
Sigrist, Markus W.
author_sort Kottmann, Jonas
collection PubMed
description Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm(−1)) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility.
format Online
Article
Text
id pubmed-3574689
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-35746892013-02-25 Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications Kottmann, Jonas Grob, Urs Rey, Julien M. Sigrist, Markus W. Sensors (Basel) Article Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm(−1)) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility. MDPI 2013-01-02 /pmc/articles/PMC3574689/ /pubmed/23282584 http://dx.doi.org/10.3390/s130100535 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Kottmann, Jonas
Grob, Urs
Rey, Julien M.
Sigrist, Markus W.
Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title_full Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title_fullStr Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title_full_unstemmed Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title_short Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
title_sort mid-infrared fiber-coupled photoacoustic sensor for biomedical applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574689/
https://www.ncbi.nlm.nih.gov/pubmed/23282584
http://dx.doi.org/10.3390/s130100535
work_keys_str_mv AT kottmannjonas midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications
AT groburs midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications
AT reyjulienm midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications
AT sigristmarkusw midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications