Cargando…
Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems h...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574689/ https://www.ncbi.nlm.nih.gov/pubmed/23282584 http://dx.doi.org/10.3390/s130100535 |
_version_ | 1782259615643205632 |
---|---|
author | Kottmann, Jonas Grob, Urs Rey, Julien M. Sigrist, Markus W. |
author_facet | Kottmann, Jonas Grob, Urs Rey, Julien M. Sigrist, Markus W. |
author_sort | Kottmann, Jonas |
collection | PubMed |
description | Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm(−1)) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility. |
format | Online Article Text |
id | pubmed-3574689 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-35746892013-02-25 Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications Kottmann, Jonas Grob, Urs Rey, Julien M. Sigrist, Markus W. Sensors (Basel) Article Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm(−1)) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility. MDPI 2013-01-02 /pmc/articles/PMC3574689/ /pubmed/23282584 http://dx.doi.org/10.3390/s130100535 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Kottmann, Jonas Grob, Urs Rey, Julien M. Sigrist, Markus W. Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title | Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title_full | Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title_fullStr | Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title_full_unstemmed | Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title_short | Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications |
title_sort | mid-infrared fiber-coupled photoacoustic sensor for biomedical applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574689/ https://www.ncbi.nlm.nih.gov/pubmed/23282584 http://dx.doi.org/10.3390/s130100535 |
work_keys_str_mv | AT kottmannjonas midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications AT groburs midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications AT reyjulienm midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications AT sigristmarkusw midinfraredfibercoupledphotoacousticsensorforbiomedicalapplications |