Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System
An automatic configuration that can detect the position of R-waves, classify the normal sinus rhythm (NSR) and other four arrhythmic types from the continuous ECG signals obtained from the MIT-BIH arrhythmia database is proposed. In this configuration, a support vector machine (SVM) was used to dete...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574706/ https://www.ncbi.nlm.nih.gov/pubmed/23303379 http://dx.doi.org/10.3390/s130100813 |
_version_ | 1782259619721117696 |
---|---|
author | Liu, Shing-Hong Cheng, Da-Chuan Lin, Chih-Ming |
author_facet | Liu, Shing-Hong Cheng, Da-Chuan Lin, Chih-Ming |
author_sort | Liu, Shing-Hong |
collection | PubMed |
description | An automatic configuration that can detect the position of R-waves, classify the normal sinus rhythm (NSR) and other four arrhythmic types from the continuous ECG signals obtained from the MIT-BIH arrhythmia database is proposed. In this configuration, a support vector machine (SVM) was used to detect and mark the ECG heartbeats with raw signals and differential signals of a lead ECG. An algorithm based on the extracted markers segments waveforms of Lead II and V1 of the ECG as the pattern classification features. A self-constructing neural fuzzy inference network (SoNFIN) was used to classify NSR and four arrhythmia types, including premature ventricular contraction (PVC), premature atrium contraction (PAC), left bundle branch block (LBBB), and right bundle branch block (RBBB). In a real scenario, the classification results show the accuracy achieved is 96.4%. This performance is suitable for a portable ECG monitor system for home care purposes. |
format | Online Article Text |
id | pubmed-3574706 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-35747062013-02-25 Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System Liu, Shing-Hong Cheng, Da-Chuan Lin, Chih-Ming Sensors (Basel) Article An automatic configuration that can detect the position of R-waves, classify the normal sinus rhythm (NSR) and other four arrhythmic types from the continuous ECG signals obtained from the MIT-BIH arrhythmia database is proposed. In this configuration, a support vector machine (SVM) was used to detect and mark the ECG heartbeats with raw signals and differential signals of a lead ECG. An algorithm based on the extracted markers segments waveforms of Lead II and V1 of the ECG as the pattern classification features. A self-constructing neural fuzzy inference network (SoNFIN) was used to classify NSR and four arrhythmia types, including premature ventricular contraction (PVC), premature atrium contraction (PAC), left bundle branch block (LBBB), and right bundle branch block (RBBB). In a real scenario, the classification results show the accuracy achieved is 96.4%. This performance is suitable for a portable ECG monitor system for home care purposes. MDPI 2013-01-09 /pmc/articles/PMC3574706/ /pubmed/23303379 http://dx.doi.org/10.3390/s130100813 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Liu, Shing-Hong Cheng, Da-Chuan Lin, Chih-Ming Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title | Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title_full | Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title_fullStr | Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title_full_unstemmed | Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title_short | Arrhythmia Identification with Two-Lead Electrocardiograms Using Artificial Neural Networks and Support Vector Machines for a Portable ECG Monitor System |
title_sort | arrhythmia identification with two-lead electrocardiograms using artificial neural networks and support vector machines for a portable ecg monitor system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574706/ https://www.ncbi.nlm.nih.gov/pubmed/23303379 http://dx.doi.org/10.3390/s130100813 |
work_keys_str_mv | AT liushinghong arrhythmiaidentificationwithtwoleadelectrocardiogramsusingartificialneuralnetworksandsupportvectormachinesforaportableecgmonitorsystem AT chengdachuan arrhythmiaidentificationwithtwoleadelectrocardiogramsusingartificialneuralnetworksandsupportvectormachinesforaportableecgmonitorsystem AT linchihming arrhythmiaidentificationwithtwoleadelectrocardiogramsusingartificialneuralnetworksandsupportvectormachinesforaportableecgmonitorsystem |