Cargando…

Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible

In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. I...

Descripción completa

Detalles Bibliográficos
Autores principales: Kenngott, H. G., Wegner, I., Neuhaus, J., Nickel, F., Fischer, L., Gehrig, T., Meinzer, H. P., Müller-Stich, B. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574972/
https://www.ncbi.nlm.nih.gov/pubmed/23440620
http://dx.doi.org/10.1007/s11701-012-0347-2
_version_ 1782259651691151360
author Kenngott, H. G.
Wegner, I.
Neuhaus, J.
Nickel, F.
Fischer, L.
Gehrig, T.
Meinzer, H. P.
Müller-Stich, B. P.
author_facet Kenngott, H. G.
Wegner, I.
Neuhaus, J.
Nickel, F.
Fischer, L.
Gehrig, T.
Meinzer, H. P.
Müller-Stich, B. P.
author_sort Kenngott, H. G.
collection PubMed
description In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. Improvement in both tissue handling and working within a narrow working space might be achieved through the use of robotic assistance. Soft tissue navigation might improve orientation by visualizing important target and risk structures intraoperatively, thereby possibly improving patient outcome. Prerequisites for navigation are its integration into the surgical workflow and accurate localization of both the instruments and patient. Magnetic tracking allows for good integration but is susceptible to distortion through metal or electro-magnetic interference, which may be caused by the operation table or a robotic system. We have investigated whether magnetic tracking can be used in combination with the da Vinci(®) (DV) telemanipulator in terms of stability and precision. We used a common magnetic tracking system (Aurora(®), NDI Inc.) with the DV in a typical operation setup. Magnetic field distortion was evaluated using a measuring facility, with the following reference system: without any metal (R), operation table alone (T), DV in standby (D) and DV in motion (Dm). The maximum error of the entire tracking volume for R, T, D and Dm was 9.9, 32.8, 37.9 and 37.2 mm, respectively. Limiting the tracking volume to 190 mm (from cranial to caudal) resulted in a maximum error of 4.0, 8.3, 8.5 and 8.9 mm, respectively. When used in the operation room, magnetic tracking shows high errors, mainly due to the operation table. The target area should be limited to increase accuracy, which is possible for most surgical applications. The use of the da Vinci(®) telemanipulator only slightly aggravates the distortion and can thus be used in combination with magnetic tracking systems.
format Online
Article
Text
id pubmed-3574972
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-35749722013-02-21 Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible Kenngott, H. G. Wegner, I. Neuhaus, J. Nickel, F. Fischer, L. Gehrig, T. Meinzer, H. P. Müller-Stich, B. P. J Robot Surg Original Article In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. Improvement in both tissue handling and working within a narrow working space might be achieved through the use of robotic assistance. Soft tissue navigation might improve orientation by visualizing important target and risk structures intraoperatively, thereby possibly improving patient outcome. Prerequisites for navigation are its integration into the surgical workflow and accurate localization of both the instruments and patient. Magnetic tracking allows for good integration but is susceptible to distortion through metal or electro-magnetic interference, which may be caused by the operation table or a robotic system. We have investigated whether magnetic tracking can be used in combination with the da Vinci(®) (DV) telemanipulator in terms of stability and precision. We used a common magnetic tracking system (Aurora(®), NDI Inc.) with the DV in a typical operation setup. Magnetic field distortion was evaluated using a measuring facility, with the following reference system: without any metal (R), operation table alone (T), DV in standby (D) and DV in motion (Dm). The maximum error of the entire tracking volume for R, T, D and Dm was 9.9, 32.8, 37.9 and 37.2 mm, respectively. Limiting the tracking volume to 190 mm (from cranial to caudal) resulted in a maximum error of 4.0, 8.3, 8.5 and 8.9 mm, respectively. When used in the operation room, magnetic tracking shows high errors, mainly due to the operation table. The target area should be limited to increase accuracy, which is possible for most surgical applications. The use of the da Vinci(®) telemanipulator only slightly aggravates the distortion and can thus be used in combination with magnetic tracking systems. Springer-Verlag 2012-03-24 2013 /pmc/articles/PMC3574972/ /pubmed/23440620 http://dx.doi.org/10.1007/s11701-012-0347-2 Text en © Springer-Verlag London Ltd 2012
spellingShingle Original Article
Kenngott, H. G.
Wegner, I.
Neuhaus, J.
Nickel, F.
Fischer, L.
Gehrig, T.
Meinzer, H. P.
Müller-Stich, B. P.
Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title_full Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title_fullStr Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title_full_unstemmed Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title_short Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
title_sort magnetic tracking in the operation room using the da vinci(®) telemanipulator is feasible
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574972/
https://www.ncbi.nlm.nih.gov/pubmed/23440620
http://dx.doi.org/10.1007/s11701-012-0347-2
work_keys_str_mv AT kenngotthg magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT wegneri magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT neuhausj magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT nickelf magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT fischerl magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT gehrigt magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT meinzerhp magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible
AT mullerstichbp magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible