Cargando…
Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible
In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. I...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574972/ https://www.ncbi.nlm.nih.gov/pubmed/23440620 http://dx.doi.org/10.1007/s11701-012-0347-2 |
_version_ | 1782259651691151360 |
---|---|
author | Kenngott, H. G. Wegner, I. Neuhaus, J. Nickel, F. Fischer, L. Gehrig, T. Meinzer, H. P. Müller-Stich, B. P. |
author_facet | Kenngott, H. G. Wegner, I. Neuhaus, J. Nickel, F. Fischer, L. Gehrig, T. Meinzer, H. P. Müller-Stich, B. P. |
author_sort | Kenngott, H. G. |
collection | PubMed |
description | In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. Improvement in both tissue handling and working within a narrow working space might be achieved through the use of robotic assistance. Soft tissue navigation might improve orientation by visualizing important target and risk structures intraoperatively, thereby possibly improving patient outcome. Prerequisites for navigation are its integration into the surgical workflow and accurate localization of both the instruments and patient. Magnetic tracking allows for good integration but is susceptible to distortion through metal or electro-magnetic interference, which may be caused by the operation table or a robotic system. We have investigated whether magnetic tracking can be used in combination with the da Vinci(®) (DV) telemanipulator in terms of stability and precision. We used a common magnetic tracking system (Aurora(®), NDI Inc.) with the DV in a typical operation setup. Magnetic field distortion was evaluated using a measuring facility, with the following reference system: without any metal (R), operation table alone (T), DV in standby (D) and DV in motion (Dm). The maximum error of the entire tracking volume for R, T, D and Dm was 9.9, 32.8, 37.9 and 37.2 mm, respectively. Limiting the tracking volume to 190 mm (from cranial to caudal) resulted in a maximum error of 4.0, 8.3, 8.5 and 8.9 mm, respectively. When used in the operation room, magnetic tracking shows high errors, mainly due to the operation table. The target area should be limited to increase accuracy, which is possible for most surgical applications. The use of the da Vinci(®) telemanipulator only slightly aggravates the distortion and can thus be used in combination with magnetic tracking systems. |
format | Online Article Text |
id | pubmed-3574972 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-35749722013-02-21 Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible Kenngott, H. G. Wegner, I. Neuhaus, J. Nickel, F. Fischer, L. Gehrig, T. Meinzer, H. P. Müller-Stich, B. P. J Robot Surg Original Article In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. Improvement in both tissue handling and working within a narrow working space might be achieved through the use of robotic assistance. Soft tissue navigation might improve orientation by visualizing important target and risk structures intraoperatively, thereby possibly improving patient outcome. Prerequisites for navigation are its integration into the surgical workflow and accurate localization of both the instruments and patient. Magnetic tracking allows for good integration but is susceptible to distortion through metal or electro-magnetic interference, which may be caused by the operation table or a robotic system. We have investigated whether magnetic tracking can be used in combination with the da Vinci(®) (DV) telemanipulator in terms of stability and precision. We used a common magnetic tracking system (Aurora(®), NDI Inc.) with the DV in a typical operation setup. Magnetic field distortion was evaluated using a measuring facility, with the following reference system: without any metal (R), operation table alone (T), DV in standby (D) and DV in motion (Dm). The maximum error of the entire tracking volume for R, T, D and Dm was 9.9, 32.8, 37.9 and 37.2 mm, respectively. Limiting the tracking volume to 190 mm (from cranial to caudal) resulted in a maximum error of 4.0, 8.3, 8.5 and 8.9 mm, respectively. When used in the operation room, magnetic tracking shows high errors, mainly due to the operation table. The target area should be limited to increase accuracy, which is possible for most surgical applications. The use of the da Vinci(®) telemanipulator only slightly aggravates the distortion and can thus be used in combination with magnetic tracking systems. Springer-Verlag 2012-03-24 2013 /pmc/articles/PMC3574972/ /pubmed/23440620 http://dx.doi.org/10.1007/s11701-012-0347-2 Text en © Springer-Verlag London Ltd 2012 |
spellingShingle | Original Article Kenngott, H. G. Wegner, I. Neuhaus, J. Nickel, F. Fischer, L. Gehrig, T. Meinzer, H. P. Müller-Stich, B. P. Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title | Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title_full | Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title_fullStr | Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title_full_unstemmed | Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title_short | Magnetic tracking in the operation room using the da Vinci(®) telemanipulator is feasible |
title_sort | magnetic tracking in the operation room using the da vinci(®) telemanipulator is feasible |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574972/ https://www.ncbi.nlm.nih.gov/pubmed/23440620 http://dx.doi.org/10.1007/s11701-012-0347-2 |
work_keys_str_mv | AT kenngotthg magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT wegneri magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT neuhausj magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT nickelf magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT fischerl magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT gehrigt magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT meinzerhp magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible AT mullerstichbp magnetictrackingintheoperationroomusingthedavincitelemanipulatorisfeasible |