Cargando…

Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis

INTRODUCTION: Studies on the association of a polymorphism in codon 72 of the p53 tumour suppressor gene (rs1042522) with cervical neoplasia have inconsistent results. While several methods for genotyping p53 exist, they vary in accuracy and are often discrepant. METHODS: We used latent class models...

Descripción completa

Detalles Bibliográficos
Autores principales: Walter, Stephen D., Riddell, Corinne A., Rabachini, Tatiana, Villa, Luisa L., Franco, Eduardo L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3575334/
https://www.ncbi.nlm.nih.gov/pubmed/23441193
http://dx.doi.org/10.1371/journal.pone.0056430
_version_ 1782259704353783808
author Walter, Stephen D.
Riddell, Corinne A.
Rabachini, Tatiana
Villa, Luisa L.
Franco, Eduardo L.
author_facet Walter, Stephen D.
Riddell, Corinne A.
Rabachini, Tatiana
Villa, Luisa L.
Franco, Eduardo L.
author_sort Walter, Stephen D.
collection PubMed
description INTRODUCTION: Studies on the association of a polymorphism in codon 72 of the p53 tumour suppressor gene (rs1042522) with cervical neoplasia have inconsistent results. While several methods for genotyping p53 exist, they vary in accuracy and are often discrepant. METHODS: We used latent class models (LCM) to examine the accuracy of six methods for p53 determination, all conducted by the same laboratory. We also examined the association of p53 with cytological cervical abnormalities, recognising potential test inaccuracy. RESULTS: Pairwise disagreement between laboratory methods occurred approximately 10% of the time. Given the estimated true p53 status of each woman, we found that each laboratory method is most likely to classify a woman to her correct status. Arg/Arg women had the highest risk of squamous intraepithelial lesions (SIL). Test accuracy was independent of cytology. There was no strong evidence for correlations of test errors. DISCUSSION: Empirical analyses ignore possible laboratory errors, and so are inherently biased, but test accuracy estimated by the LCM approach is unbiased when model assumptions are met. LCM analysis avoids ambiguities arising from empirical test discrepancies, obviating the need to regard any of the methods as a “gold” standard measurement. The methods we presented here to analyse the p53 data can be applied in many other situations where multiple tests exist, but where none of them is a gold standard.
format Online
Article
Text
id pubmed-3575334
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35753342013-02-25 Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis Walter, Stephen D. Riddell, Corinne A. Rabachini, Tatiana Villa, Luisa L. Franco, Eduardo L. PLoS One Research Article INTRODUCTION: Studies on the association of a polymorphism in codon 72 of the p53 tumour suppressor gene (rs1042522) with cervical neoplasia have inconsistent results. While several methods for genotyping p53 exist, they vary in accuracy and are often discrepant. METHODS: We used latent class models (LCM) to examine the accuracy of six methods for p53 determination, all conducted by the same laboratory. We also examined the association of p53 with cytological cervical abnormalities, recognising potential test inaccuracy. RESULTS: Pairwise disagreement between laboratory methods occurred approximately 10% of the time. Given the estimated true p53 status of each woman, we found that each laboratory method is most likely to classify a woman to her correct status. Arg/Arg women had the highest risk of squamous intraepithelial lesions (SIL). Test accuracy was independent of cytology. There was no strong evidence for correlations of test errors. DISCUSSION: Empirical analyses ignore possible laboratory errors, and so are inherently biased, but test accuracy estimated by the LCM approach is unbiased when model assumptions are met. LCM analysis avoids ambiguities arising from empirical test discrepancies, obviating the need to regard any of the methods as a “gold” standard measurement. The methods we presented here to analyse the p53 data can be applied in many other situations where multiple tests exist, but where none of them is a gold standard. Public Library of Science 2013-02-18 /pmc/articles/PMC3575334/ /pubmed/23441193 http://dx.doi.org/10.1371/journal.pone.0056430 Text en © 2013 Walter et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Walter, Stephen D.
Riddell, Corinne A.
Rabachini, Tatiana
Villa, Luisa L.
Franco, Eduardo L.
Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title_full Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title_fullStr Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title_full_unstemmed Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title_short Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis
title_sort accuracy of p53 codon 72 polymorphism status determined by multiple laboratory methods: a latent class model analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3575334/
https://www.ncbi.nlm.nih.gov/pubmed/23441193
http://dx.doi.org/10.1371/journal.pone.0056430
work_keys_str_mv AT walterstephend accuracyofp53codon72polymorphismstatusdeterminedbymultiplelaboratorymethodsalatentclassmodelanalysis
AT riddellcorinnea accuracyofp53codon72polymorphismstatusdeterminedbymultiplelaboratorymethodsalatentclassmodelanalysis
AT rabachinitatiana accuracyofp53codon72polymorphismstatusdeterminedbymultiplelaboratorymethodsalatentclassmodelanalysis
AT villaluisal accuracyofp53codon72polymorphismstatusdeterminedbymultiplelaboratorymethodsalatentclassmodelanalysis
AT francoeduardol accuracyofp53codon72polymorphismstatusdeterminedbymultiplelaboratorymethodsalatentclassmodelanalysis