Cargando…

An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement

Competitive inhibition diminishes ligand adhesion as receptor sites become occupied with competing ligands. It is unknown if this effect occurs in ultrasound molecular imaging studies where endothelial binding sites become occupied with adherent bubbles or bubble fragments. The goal of this pilot st...

Descripción completa

Detalles Bibliográficos
Autores principales: Streeter, Jason E., Dayton, Paul A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3575589/
https://www.ncbi.nlm.nih.gov/pubmed/23424189
http://dx.doi.org/10.7150/thno.5341
_version_ 1782259754808115200
author Streeter, Jason E.
Dayton, Paul A.
author_facet Streeter, Jason E.
Dayton, Paul A.
author_sort Streeter, Jason E.
collection PubMed
description Competitive inhibition diminishes ligand adhesion as receptor sites become occupied with competing ligands. It is unknown if this effect occurs in ultrasound molecular imaging studies where endothelial binding sites become occupied with adherent bubbles or bubble fragments. The goal of this pilot study was to assess the effect that repeated administration and clearance of targeted agents has on successive adhesion. Two groups of animals were imaged with 3-D ultrasonic molecular imaging. Injections and imaging were performed on Group 1 at time 0 and 60 minutes. Group 2 received injections of microbubbles at 0, 15, 30, 45 and 60 minutes with imaging at 0 and 60 minutes. At 60 minutes, Group 1 targeting relative to baseline was not significantly different from Group 2 (1.06±0.27 vs. 1.08±0.34, p=0.93). Data suggest that multiple injections of targeted microbubbles do not block sufficient binding sites to bias molecular imaging data in serial studies.
format Online
Article
Text
id pubmed-3575589
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-35755892013-02-19 An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement Streeter, Jason E. Dayton, Paul A. Theranostics Short Research Communication Competitive inhibition diminishes ligand adhesion as receptor sites become occupied with competing ligands. It is unknown if this effect occurs in ultrasound molecular imaging studies where endothelial binding sites become occupied with adherent bubbles or bubble fragments. The goal of this pilot study was to assess the effect that repeated administration and clearance of targeted agents has on successive adhesion. Two groups of animals were imaged with 3-D ultrasonic molecular imaging. Injections and imaging were performed on Group 1 at time 0 and 60 minutes. Group 2 received injections of microbubbles at 0, 15, 30, 45 and 60 minutes with imaging at 0 and 60 minutes. At 60 minutes, Group 1 targeting relative to baseline was not significantly different from Group 2 (1.06±0.27 vs. 1.08±0.34, p=0.93). Data suggest that multiple injections of targeted microbubbles do not block sufficient binding sites to bias molecular imaging data in serial studies. Ivyspring International Publisher 2013-01-17 /pmc/articles/PMC3575589/ /pubmed/23424189 http://dx.doi.org/10.7150/thno.5341 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited.
spellingShingle Short Research Communication
Streeter, Jason E.
Dayton, Paul A.
An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title_full An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title_fullStr An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title_full_unstemmed An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title_short An In Vivo Evaluation of the Effect of Repeated Administration and Clearance of Targeted Contrast Agents on Molecular Imaging Signal Enhancement
title_sort in vivo evaluation of the effect of repeated administration and clearance of targeted contrast agents on molecular imaging signal enhancement
topic Short Research Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3575589/
https://www.ncbi.nlm.nih.gov/pubmed/23424189
http://dx.doi.org/10.7150/thno.5341
work_keys_str_mv AT streeterjasone aninvivoevaluationoftheeffectofrepeatedadministrationandclearanceoftargetedcontrastagentsonmolecularimagingsignalenhancement
AT daytonpaula aninvivoevaluationoftheeffectofrepeatedadministrationandclearanceoftargetedcontrastagentsonmolecularimagingsignalenhancement
AT streeterjasone invivoevaluationoftheeffectofrepeatedadministrationandclearanceoftargetedcontrastagentsonmolecularimagingsignalenhancement
AT daytonpaula invivoevaluationoftheeffectofrepeatedadministrationandclearanceoftargetedcontrastagentsonmolecularimagingsignalenhancement