Cargando…

Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)

BACKGROUND: The need to improve patient safety has been identified as a major priority for health reform in developed countries, including Australia. We investigated the implementation and appropriateness of Variable Life Adjusted Displays as a quality control procedure to monitor “in-control” versu...

Descripción completa

Detalles Bibliográficos
Autores principales: Andrianopoulos, Nick, Jolley, Damien, Evans, Sue M, Brand, Caroline A, Cameron, Peter A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3576249/
https://www.ncbi.nlm.nih.gov/pubmed/22925089
http://dx.doi.org/10.1186/1472-6963-12-278
_version_ 1782259821681049600
author Andrianopoulos, Nick
Jolley, Damien
Evans, Sue M
Brand, Caroline A
Cameron, Peter A
author_facet Andrianopoulos, Nick
Jolley, Damien
Evans, Sue M
Brand, Caroline A
Cameron, Peter A
author_sort Andrianopoulos, Nick
collection PubMed
description BACKGROUND: The need to improve patient safety has been identified as a major priority for health reform in developed countries, including Australia. We investigated the implementation and appropriateness of Variable Life Adjusted Displays as a quality control procedure to monitor “in-control” versus “out-of-control” processes in Victorian public hospitals. METHODS: Victorian Admitted Episode Data from Department of Human Services, Victoria for 2004–7 were used. The VLAD is a plot of a cumulative sum of the difference in expected outcome (range 0–1) and observed outcome (0 or 1) for sequential separations. Three outcomes were assessed: in-hospital mortality for acute myocardial infarction, stroke and heart failure. Logistic regression was used to obtain a realistic measure of expected mortality over the period 2004–5, adjusting for covariates and comorbidities, to estimate expected mortality risk for the separations between 2005–7. VLAD were plotted for the years 2005–7, by the 11 hospitals with the highest frequency of separations. Signalling limits for 30%, 50% and 75% risk decrease and risk increase were determined and plotted for each VLAD utilizing risk-adjusted cumulative sum techniques. This is a likelihood-ratio test statistic for signalling. If the VLAD signalled by intersecting with a limit, the limit was reset. RESULTS: The three logit models displayed reasonable fit to the observed data. There were n = 2999 separations in the AMI model, n = 3598 in the HF model and n = 1922 in the stroke model. The number of separations plotted by VLAD ranged from n = 126 to n = 648. No signals were observed in 64%, 55% and 18% of VLAD for AMI, HF and stroke respectively. For AMI and HF 9% of hospitals signalled at least once for each of 30%, 50% and 75% risk increase, whereas this was 45% for stroke. Hospitals signalling at least once for risk decrease ranged from 18% to 36% across the levels of risk and outcomes. No VLAD signalled for both risk decrease and increase. CONCLUSIONS: VLAD intersecting with limits to signal “out-of-control” states, may be an appropriate technique to help hospitals assess quality control. Preliminary work displays some between hospital differences. Relevant signals can be used to investigate why a system is potentially performing better than or worse than expected. Types and levels of investigation could depend on the type of signalling. Validation work, for example attempting to correlate signals with clinical notes, prior to VLAD distribution needs to be undertaken.
format Online
Article
Text
id pubmed-3576249
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35762492013-02-22 Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED) Andrianopoulos, Nick Jolley, Damien Evans, Sue M Brand, Caroline A Cameron, Peter A BMC Health Serv Res Research Article BACKGROUND: The need to improve patient safety has been identified as a major priority for health reform in developed countries, including Australia. We investigated the implementation and appropriateness of Variable Life Adjusted Displays as a quality control procedure to monitor “in-control” versus “out-of-control” processes in Victorian public hospitals. METHODS: Victorian Admitted Episode Data from Department of Human Services, Victoria for 2004–7 were used. The VLAD is a plot of a cumulative sum of the difference in expected outcome (range 0–1) and observed outcome (0 or 1) for sequential separations. Three outcomes were assessed: in-hospital mortality for acute myocardial infarction, stroke and heart failure. Logistic regression was used to obtain a realistic measure of expected mortality over the period 2004–5, adjusting for covariates and comorbidities, to estimate expected mortality risk for the separations between 2005–7. VLAD were plotted for the years 2005–7, by the 11 hospitals with the highest frequency of separations. Signalling limits for 30%, 50% and 75% risk decrease and risk increase were determined and plotted for each VLAD utilizing risk-adjusted cumulative sum techniques. This is a likelihood-ratio test statistic for signalling. If the VLAD signalled by intersecting with a limit, the limit was reset. RESULTS: The three logit models displayed reasonable fit to the observed data. There were n = 2999 separations in the AMI model, n = 3598 in the HF model and n = 1922 in the stroke model. The number of separations plotted by VLAD ranged from n = 126 to n = 648. No signals were observed in 64%, 55% and 18% of VLAD for AMI, HF and stroke respectively. For AMI and HF 9% of hospitals signalled at least once for each of 30%, 50% and 75% risk increase, whereas this was 45% for stroke. Hospitals signalling at least once for risk decrease ranged from 18% to 36% across the levels of risk and outcomes. No VLAD signalled for both risk decrease and increase. CONCLUSIONS: VLAD intersecting with limits to signal “out-of-control” states, may be an appropriate technique to help hospitals assess quality control. Preliminary work displays some between hospital differences. Relevant signals can be used to investigate why a system is potentially performing better than or worse than expected. Types and levels of investigation could depend on the type of signalling. Validation work, for example attempting to correlate signals with clinical notes, prior to VLAD distribution needs to be undertaken. BioMed Central 2012-08-28 /pmc/articles/PMC3576249/ /pubmed/22925089 http://dx.doi.org/10.1186/1472-6963-12-278 Text en Copyright ©2012 Andrianopoulos et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Andrianopoulos, Nick
Jolley, Damien
Evans, Sue M
Brand, Caroline A
Cameron, Peter A
Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title_full Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title_fullStr Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title_full_unstemmed Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title_short Application of Variable Life Adjusted Displays (VLAD) on Victorian Admitted Episodes Dataset (VAED)
title_sort application of variable life adjusted displays (vlad) on victorian admitted episodes dataset (vaed)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3576249/
https://www.ncbi.nlm.nih.gov/pubmed/22925089
http://dx.doi.org/10.1186/1472-6963-12-278
work_keys_str_mv AT andrianopoulosnick applicationofvariablelifeadjusteddisplaysvladonvictorianadmittedepisodesdatasetvaed
AT jolleydamien applicationofvariablelifeadjusteddisplaysvladonvictorianadmittedepisodesdatasetvaed
AT evanssuem applicationofvariablelifeadjusteddisplaysvladonvictorianadmittedepisodesdatasetvaed
AT brandcarolinea applicationofvariablelifeadjusteddisplaysvladonvictorianadmittedepisodesdatasetvaed
AT cameronpetera applicationofvariablelifeadjusteddisplaysvladonvictorianadmittedepisodesdatasetvaed