Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study
AIM: To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT). METHODS AND MATERIALS: Prospectively-gated CCTA...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3577795/ https://www.ncbi.nlm.nih.gov/pubmed/23437110 http://dx.doi.org/10.1371/journal.pone.0056295 |
_version_ | 1782259974248857600 |
---|---|
author | Hou, Yang Zheng, Jiahe Wang, Yuke Yu, Mei Vembar, Mani Guo, Qiyong |
author_facet | Hou, Yang Zheng, Jiahe Wang, Yuke Yu, Mei Vembar, Mani Guo, Qiyong |
author_sort | Hou, Yang |
collection | PubMed |
description | AIM: To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT). METHODS AND MATERIALS: Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the tube output gradually reduced from 210 mAs (Group A) to 125, 105, 84, and 63 mAs (Group B–E). All scans were reconstructed using filtered back projection (FBP) algorithm and five IRT levels (L2-6), image quality (IQ) assessment was performed. Based on the IQ assessment, Group D(120 kVp, 84 mAs) reconstructed with L5 was found to provide IQ comparable to that of Group A with FBP. In the patient study, 21 patients underwent CCTA using 120 kV, 210 mAs with FBP reconstruction (Group 1) followed by 36 patients scanned with 120 kV, 84 mAs with IRT L5 (Group 2). Subjective and objective IQ and effective radiation dose were compared between two groups. RESULTS: In the phantom scans, there were no significant differences in image noise, contrast-to-noise ratio (CNR) and modulation transfer function (MTF) curves between Group A and the 84 mAs, 63 mAs groups (Groups D and E). Group D (120 kV, 84 mAs and L5) provided an optimum balance, producing equivalent image quality to Group A, at the lowest possible radiation dose. In the patient study, there were no significant difference in image noise, signal-to-noise ratio (SNR) and CNR between Group 1 and Group 2 (p = 0.71, 0.31, 0.5, respectively). The effective radiation dose in Group 2 was 1.21±0.14 mSv compared to 3.20±0.58 mSv (Group 1), reflecting dose savings of 62.5% (p<0.05). CONCLUSION: iterative reconstruction technique used in prospectively ECG-triggered 256-slice coronary CTA can provide radiation dose reductions of up to 62.5% with acceptable image quality. |
format | Online Article Text |
id | pubmed-3577795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-35777952013-02-22 Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study Hou, Yang Zheng, Jiahe Wang, Yuke Yu, Mei Vembar, Mani Guo, Qiyong PLoS One Research Article AIM: To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT). METHODS AND MATERIALS: Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the tube output gradually reduced from 210 mAs (Group A) to 125, 105, 84, and 63 mAs (Group B–E). All scans were reconstructed using filtered back projection (FBP) algorithm and five IRT levels (L2-6), image quality (IQ) assessment was performed. Based on the IQ assessment, Group D(120 kVp, 84 mAs) reconstructed with L5 was found to provide IQ comparable to that of Group A with FBP. In the patient study, 21 patients underwent CCTA using 120 kV, 210 mAs with FBP reconstruction (Group 1) followed by 36 patients scanned with 120 kV, 84 mAs with IRT L5 (Group 2). Subjective and objective IQ and effective radiation dose were compared between two groups. RESULTS: In the phantom scans, there were no significant differences in image noise, contrast-to-noise ratio (CNR) and modulation transfer function (MTF) curves between Group A and the 84 mAs, 63 mAs groups (Groups D and E). Group D (120 kV, 84 mAs and L5) provided an optimum balance, producing equivalent image quality to Group A, at the lowest possible radiation dose. In the patient study, there were no significant difference in image noise, signal-to-noise ratio (SNR) and CNR between Group 1 and Group 2 (p = 0.71, 0.31, 0.5, respectively). The effective radiation dose in Group 2 was 1.21±0.14 mSv compared to 3.20±0.58 mSv (Group 1), reflecting dose savings of 62.5% (p<0.05). CONCLUSION: iterative reconstruction technique used in prospectively ECG-triggered 256-slice coronary CTA can provide radiation dose reductions of up to 62.5% with acceptable image quality. Public Library of Science 2013-02-20 /pmc/articles/PMC3577795/ /pubmed/23437110 http://dx.doi.org/10.1371/journal.pone.0056295 Text en © 2013 Hou et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Hou, Yang Zheng, Jiahe Wang, Yuke Yu, Mei Vembar, Mani Guo, Qiyong Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title | Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title_full | Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title_fullStr | Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title_full_unstemmed | Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title_short | Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study |
title_sort | optimizing radiation dose levels in prospectively electrocardiogram-triggered coronary computed tomography angiography using iterative reconstruction techniques: a phantom and patient study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3577795/ https://www.ncbi.nlm.nih.gov/pubmed/23437110 http://dx.doi.org/10.1371/journal.pone.0056295 |
work_keys_str_mv | AT houyang optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy AT zhengjiahe optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy AT wangyuke optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy AT yumei optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy AT vembarmani optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy AT guoqiyong optimizingradiationdoselevelsinprospectivelyelectrocardiogramtriggeredcoronarycomputedtomographyangiographyusingiterativereconstructiontechniquesaphantomandpatientstudy |