Cargando…

A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial

AIMS: The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS: The trial's primary objective was to randomly compare the proportions of patients experiencing ≥1 major adverse even...

Descripción completa

Detalles Bibliográficos
Autores principales: Guédon-Moreau, Laurence, Lacroix, Dominique, Sadoul, Nicolas, Clémenty, Jacques, Kouakam, Claude, Hermida, Jean-Sylvain, Aliot, Etienne, Boursier, Michel, Bizeau, Olivier, Kacet, Salem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3578267/
https://www.ncbi.nlm.nih.gov/pubmed/23242192
http://dx.doi.org/10.1093/eurheartj/ehs425
Descripción
Sumario:AIMS: The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS: The trial's primary objective was to randomly compare the proportions of patients experiencing ≥1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related MAE associated with HM (active group) vs. ambulatory follow-ups (control group) in a sample of 433 patients. The 221 patients assigned to the active group were seen once a year, unless HM reported an ICD dysfunction or a clinical event requiring an ambulatory visit, while the 212 patients in the control group underwent ambulatory visits every 6 months. The characteristics of the study groups were similar. Over a follow-up of 24.2 months, 38.5% of patients in the active and 41.5% in the control group experienced ≥1 MAE (P < 0.05 for non-inferiority). The overall number of shocks delivered was significantly lower in the active (n = 193) than in the control (n = 657) group (P < 0.05) and the proportion of patients who received inappropriate shocks was 52% lower in the active (n = 11) than in the control (n = 22) group (P < 0.05). At the end of the follow-up, the battery longevity was longer in the active group because of a lower number of capacitor charges (499 vs. 2081). CONCLUSION: Our observations indicate that long-term HM of ICD is at least as safe as standard ambulatory follow-ups with respect to a broad spectrum of MAE. It also lowered significantly the number of appropriate and inappropriate shocks delivered, and spared the device battery. CLINICAL TRIALS REGISTRATION: NCT00989417.