Cargando…

PHILOS humerus plate for a distal tibial fracture

This report discusses the use of an alternative implant in the emergency fixation of a distal tibial fracture. We planned to fix the shear-type medial malleolar fracture in a closed, tri-malleolar fracture with a locking distal tibial plate. Intra-operatively, it was noted that the required plate wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Twaij, Haider, Damany, Dev
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3578666/
https://www.ncbi.nlm.nih.gov/pubmed/24963933
http://dx.doi.org/10.1093/jscr/rjs036
Descripción
Sumario:This report discusses the use of an alternative implant in the emergency fixation of a distal tibial fracture. We planned to fix the shear-type medial malleolar fracture in a closed, tri-malleolar fracture with a locking distal tibial plate. Intra-operatively, it was noted that the required plate was unavailable. A PHILOS humeral plate seemed to fit the contours of the distal tibia. The broad end of the PHILOS, when placed distally, gave options to place locking screws in the medial malleolar fragment. The fracture was stable after fixation. The patient made a full post-operative recovery and follow-up at 4 months was satisfactory. Despite adequate planning, there will be instances where one has to improvise. An understanding of the principles of fracture management can aid in finding solutions. PHILOS humeral plate may be used to stabilize a distal tibial fracture if an appropriate distal tibial locking plate is not available.