Cargando…

The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements

In recent years, X-ray radiography has been used to probe the internal structure of dense sprays with microsecond time resolution and a spatial resolution of 15 µm even in high-pressure environments. Recently, the 7BM beamline at the Advanced Photon Source (APS) has been commissioned to focus on the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kastengren, Alan, Powell, Christopher F., Arms, Dohn, Dufresne, Eric M., Gibson, Harold, Wang, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3579593/
https://www.ncbi.nlm.nih.gov/pubmed/22713903
http://dx.doi.org/10.1107/S0909049512016883
_version_ 1782260138843832320
author Kastengren, Alan
Powell, Christopher F.
Arms, Dohn
Dufresne, Eric M.
Gibson, Harold
Wang, Jin
author_facet Kastengren, Alan
Powell, Christopher F.
Arms, Dohn
Dufresne, Eric M.
Gibson, Harold
Wang, Jin
author_sort Kastengren, Alan
collection PubMed
description In recent years, X-ray radiography has been used to probe the internal structure of dense sprays with microsecond time resolution and a spatial resolution of 15 µm even in high-pressure environments. Recently, the 7BM beamline at the Advanced Photon Source (APS) has been commissioned to focus on the needs of X-ray spray radiography measurements. The spatial resolution and X-ray intensity at this beamline represent a significant improvement over previous time-resolved X-ray radiography measurements at the APS.
format Online
Article
Text
id pubmed-3579593
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-35795932013-02-27 The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements Kastengren, Alan Powell, Christopher F. Arms, Dohn Dufresne, Eric M. Gibson, Harold Wang, Jin J Synchrotron Radiat Beamlines In recent years, X-ray radiography has been used to probe the internal structure of dense sprays with microsecond time resolution and a spatial resolution of 15 µm even in high-pressure environments. Recently, the 7BM beamline at the Advanced Photon Source (APS) has been commissioned to focus on the needs of X-ray spray radiography measurements. The spatial resolution and X-ray intensity at this beamline represent a significant improvement over previous time-resolved X-ray radiography measurements at the APS. International Union of Crystallography 2012-07-01 2012-05-11 /pmc/articles/PMC3579593/ /pubmed/22713903 http://dx.doi.org/10.1107/S0909049512016883 Text en © Alan Kastengren et al. 2012 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Beamlines
Kastengren, Alan
Powell, Christopher F.
Arms, Dohn
Dufresne, Eric M.
Gibson, Harold
Wang, Jin
The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title_full The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title_fullStr The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title_full_unstemmed The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title_short The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements
title_sort 7bm beamline at the aps: a facility for time-resolved fluid dynamics measurements
topic Beamlines
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3579593/
https://www.ncbi.nlm.nih.gov/pubmed/22713903
http://dx.doi.org/10.1107/S0909049512016883
work_keys_str_mv AT kastengrenalan the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT powellchristopherf the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT armsdohn the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT dufresneericm the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT gibsonharold the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT wangjin the7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT kastengrenalan 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT powellchristopherf 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT armsdohn 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT dufresneericm 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT gibsonharold 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements
AT wangjin 7bmbeamlineattheapsafacilityfortimeresolvedfluiddynamicsmeasurements