Cargando…
Reconstruction of Saccular and Dissected Intracranial Aneurysms Using Solitaire™ AB Stents
INTRODUCTION: We aimed to evaluate the feasibility, safety, efficacy, and predictors for outcome of reconstructive treatment with Solitaire™ AB stent(s) based on 54 cases of saccular aneurysms and 14 of acute symptomatic dissecting aneurysms. METHODS: Fifty-eight consecutive patients (M/F = 28/30; m...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3582555/ https://www.ncbi.nlm.nih.gov/pubmed/23468947 http://dx.doi.org/10.1371/journal.pone.0057253 |
Sumario: | INTRODUCTION: We aimed to evaluate the feasibility, safety, efficacy, and predictors for outcome of reconstructive treatment with Solitaire™ AB stent(s) based on 54 cases of saccular aneurysms and 14 of acute symptomatic dissecting aneurysms. METHODS: Fifty-eight consecutive patients (M/F = 28/30; median age, 53 years) harbouring 68 aneurysms (ruptured/unruptured = 12/56) underwent treatment with Solitaire™ AB stent(s) implantation between April 2010 and August 2011 in our institution. The data were retrospectively reviewed and analysed. RESULTS: The technical success rate of Solitaire™ AB stenting was 100%. The rates of the overall and the treatment-related adverse events were 9% (6/68) and 6% (4/68), respectively, and the recurrent rate was 1% (1/68). All of the adverse events (n = 6) occurred in tiny (n = 1, ≤3 mm) or small (n = 5, >3 to ≤10 mm) aneurysms. The majority (75%, 3/4) of thromboembolic events (thrombus, n = 2; infarction, n = 2) occurred in ruptured lesions, and 2 intraprocedural aneurysm ruptures occurred in the course of coiling when the stent(s) was/were applied within 6 months. Subarachnoid haemorrhages (SAH, p<0.05) and immediate occlusion grades (p<0.05) were predictors for overall adverse events by univariate analysis. Compared with the immediate post-treatment angiographic results, the follow-up angiographic imaging (mean, 13 months; range, 6–25 months) revealed that stent(s) implantation enhanced the rate of class I occlusion from 34% (23/68) to 93% (63/68). SAH was the only predictor for unfavourable outcomes (the modified Rankin Scale score [mRS], 2–6) during the mean 19-month (range, 12–27 months) of clinical follow-ups (p<0.05). CONCLUSIONS: Although the complete obliteration of tiny and small aneurysms without complications remains a challenge, stent(s) implantation could lead to further occlusion of incompletely coiled aneurysms. SAH and the occlusion grade were the primary predictors for adverse events. SAH was the only predictor for unfavourable outcomes by univariate analysis. |
---|