Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter

We report a novel noncontact diffuse correlation spectroscopy flow-oximeter for simultaneous quantification of relative changes in tissue blood flow (rBF) and oxygenation (Δ[oxygenation]). The noncontact probe was compared against a contact probe in tissue-like phantoms and forearm muscles (n = 10),...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Ting, Lin, Yu, Shang, Yu, He, Lian, Huang, Chong, Szabunio, Margaret, Yu, Guoqiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3584314/
https://www.ncbi.nlm.nih.gov/pubmed/23446991
http://dx.doi.org/10.1038/srep01358
_version_ 1782261015281401856
author Li, Ting
Lin, Yu
Shang, Yu
He, Lian
Huang, Chong
Szabunio, Margaret
Yu, Guoqiang
author_facet Li, Ting
Lin, Yu
Shang, Yu
He, Lian
Huang, Chong
Szabunio, Margaret
Yu, Guoqiang
author_sort Li, Ting
collection PubMed
description We report a novel noncontact diffuse correlation spectroscopy flow-oximeter for simultaneous quantification of relative changes in tissue blood flow (rBF) and oxygenation (Δ[oxygenation]). The noncontact probe was compared against a contact probe in tissue-like phantoms and forearm muscles (n = 10), and the dynamic trends in both rBF and Δ[oxygenation] were found to be highly correlated. However, the magnitudes of Δ[oxygenation] measured by the two probes were significantly different. Monte Carlo simulations and phantom experiments revealed that the arm curvature resulted in a significant underestimation (~−20%) for the noncontact measurements in Δ[oxygenation], but not in rBF. Other factors that may cause the residual discrepancies between the contact and noncontact measurements were discussed, and further comparisons with other established technologies are needed to identify/quantify these factors. Our research paves the way for noncontact and simultaneous monitoring of blood flow and oxygenation in soft and vulnerable tissues without distorting tissue hemodynamics.
format Online
Article
Text
id pubmed-3584314
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-35843142013-02-28 Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter Li, Ting Lin, Yu Shang, Yu He, Lian Huang, Chong Szabunio, Margaret Yu, Guoqiang Sci Rep Article We report a novel noncontact diffuse correlation spectroscopy flow-oximeter for simultaneous quantification of relative changes in tissue blood flow (rBF) and oxygenation (Δ[oxygenation]). The noncontact probe was compared against a contact probe in tissue-like phantoms and forearm muscles (n = 10), and the dynamic trends in both rBF and Δ[oxygenation] were found to be highly correlated. However, the magnitudes of Δ[oxygenation] measured by the two probes were significantly different. Monte Carlo simulations and phantom experiments revealed that the arm curvature resulted in a significant underestimation (~−20%) for the noncontact measurements in Δ[oxygenation], but not in rBF. Other factors that may cause the residual discrepancies between the contact and noncontact measurements were discussed, and further comparisons with other established technologies are needed to identify/quantify these factors. Our research paves the way for noncontact and simultaneous monitoring of blood flow and oxygenation in soft and vulnerable tissues without distorting tissue hemodynamics. Nature Publishing Group 2013-02-28 /pmc/articles/PMC3584314/ /pubmed/23446991 http://dx.doi.org/10.1038/srep01358 Text en Copyright © 2013, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Article
Li, Ting
Lin, Yu
Shang, Yu
He, Lian
Huang, Chong
Szabunio, Margaret
Yu, Guoqiang
Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title_full Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title_fullStr Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title_full_unstemmed Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title_short Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
title_sort simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3584314/
https://www.ncbi.nlm.nih.gov/pubmed/23446991
http://dx.doi.org/10.1038/srep01358
work_keys_str_mv AT liting simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT linyu simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT shangyu simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT helian simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT huangchong simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT szabuniomargaret simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter
AT yuguoqiang simultaneousmeasurementofdeeptissuebloodflowandoxygenationusingnoncontactdiffusecorrelationspectroscopyflowoximeter