Failure of intertrochanteric nailing due to distal nail jamming

Nail impingement against the anterior femoral cortex during nail insertion, or anterior cortex penetration, has been described in the literature as a worrying complication. We describe a previously unreported surgical failure due to a compromised dynamic distal locking caused by distal jamming of th...